Area of interest/field-of-view research using ASPT.

1978 ◽  
Author(s):  
W. Dean LeMaster ◽  
Thomas M. Longridge
Author(s):  
Erick Kim ◽  
Kamjou Mansour ◽  
Gil Garteiz ◽  
Javeck Verdugo ◽  
Ryan Ross ◽  
...  

Abstract This paper presents the failure analysis on a 1.5m flex harness for a space flight instrument that exhibited two failure modes: global isolation resistances between all adjacent traces measured tens of milliohm and lower resistance on the order of 1 kiloohm was observed on several pins. It shows a novel method using a temperature controlled air stream while monitoring isolation resistance to identify a general area of interest of a low isolation resistance failure. The paper explains how isolation resistance measurements were taken and details the steps taken in both destructive and non-destructive analyses. In theory, infrared hotspot could have been completed along the length of the flex harness to locate the failure site. However, with a field of view of approximately 5 x 5 cm, this technique would have been time prohibitive.


2014 ◽  
Vol 121 (3) ◽  
pp. 688-699
Author(s):  
Kay Niklas Liebig ◽  
Homajoun Maslehaty ◽  
Athanasios K. Petridis ◽  
Wolfgang Konen ◽  
Martin Scholz

Object Neuroendoscopy is used more and more frequently in neurosurgical procedures and has become an important tool in the neurosurgical armamentarium. However, the main restriction of neuroendoscopy is the limited field of view. A better overview of the area of interest would increase surgical safety and decrease procedure-related morbidity rates. In the present study, the authors aimed to improve this restriction by using and comparing two algorithms to create endoscopic panoramic images, which increase the field of view during neuroendoscopic procedures. Methods Different endoscopic methods with or without a stand and with linear or circular endoscope movements were performed in cadaveric ventricles. Video of the endoscopy was used to create image mosaics of the lateral ventricle with the help of the Kourogi or LogSearch (LS) algorithm. In the LS algorithm, different template sizes were used. Three observers graded the quality of the image mosaic in terms of usefulness in surgery. The fastest frame rate was 3–4 frames/second. Results The LS algorithm with a larger template size showed significantly better results for the creation of image mosaics than the Kourogi algorithm in linear endoscopic movement with or without a stand. In circular endoscopic movements, the results seemed to be better with the LS algorithm but were not significantly different from those obtained with the Kourogi algorithm. In summary, image quality in the experimental paradigms was satisfying. Conclusions Results in the study showed that the creation of image mosaics is possible and reliable with the featured algorithms. Image mosaicking is an applicable device for neuroendoscopy and can increase the field of view during endoscopic procedures. Its use can increase the safety and the field of application of neuroendoscopy. However, faster frame rates will be required to create a smooth image for practical use during surgery.


Author(s):  
Helge Aasen

Hyperspectral data has great potential for vegetation parameter retrieval. However, due to angular effects resulting from different sun-surface-sensor geometries, objects might appear differently depending on the position of an object within the field of view of a sensor. Recently, lightweight snapshot cameras have been introduced, which capture hyperspectral information in two spatial and one spectral dimension and can be mounted on unmanned aerial vehicles. <br><br> This study investigates the influence of the different viewing geometries within an image on the apparent hyperspectral reflection retrieved by these sensors. Additionally, it is evaluated how hyperspectral vegetation indices like the NDVI are effected by the angular effects within a single image and if the viewing geometry influences the apparent heterogeneity with an area of interest. The study is carried out for a barley canopy at booting stage. <br><br> The results show significant influences of the position of the area of interest within the image. The red region of the spectrum is more influenced by the position than the near infrared. The ability of the NDVI to compensate these effects was limited to the capturing positions close to nadir. The apparent heterogeneity of the area of interest is the highest close to a nadir.


Author(s):  
Helge Aasen

Hyperspectral data has great potential for vegetation parameter retrieval. However, due to angular effects resulting from different sun-surface-sensor geometries, objects might appear differently depending on the position of an object within the field of view of a sensor. Recently, lightweight snapshot cameras have been introduced, which capture hyperspectral information in two spatial and one spectral dimension and can be mounted on unmanned aerial vehicles. &lt;br&gt;&lt;br&gt; This study investigates the influence of the different viewing geometries within an image on the apparent hyperspectral reflection retrieved by these sensors. Additionally, it is evaluated how hyperspectral vegetation indices like the NDVI are effected by the angular effects within a single image and if the viewing geometry influences the apparent heterogeneity with an area of interest. The study is carried out for a barley canopy at booting stage. &lt;br&gt;&lt;br&gt; The results show significant influences of the position of the area of interest within the image. The red region of the spectrum is more influenced by the position than the near infrared. The ability of the NDVI to compensate these effects was limited to the capturing positions close to nadir. The apparent heterogeneity of the area of interest is the highest close to a nadir.


Author(s):  
Afaf Mosaif, Et. al.

In recent years, wireless sensor networks have been used in a wide range of applications such as smart cities, military, and environmental monitoring. Target tracking is one of the most interesting applications in this area of research, which mainly consists of detecting the targets that move in the area of interest and monitoring their motions. However, tracking a target using visual sensors is different and more difficult than that of scalar sensors due to the special characteristics of visual sensors, such as their directional limited field of view, and the nature and amount of the sensed data. In this paper, we first present the challenges of detection and target tracking in wireless visual sensor networks, then we propose a scheme that describes the basic steps of target tracking in these networks, we focus then on the tracking across camera nodes by presenting some metrics that can be considered when designing and evaluating this type of tracking approaches.


1994 ◽  
Vol 144 ◽  
pp. 593-596
Author(s):  
O. Bouchard ◽  
S. Koutchmy ◽  
L. November ◽  
J.-C. Vial ◽  
J. B. Zirker

AbstractWe present the results of the analysis of a movie taken over a small field of view in the intermediate corona at a spatial resolution of 0.5“, a temporal resolution of 1 s and a spectral passband of 7 nm. These CCD observations were made at the prime focus of the 3.6 m aperture CFHT telescope during the 1991 total solar eclipse.


Author(s):  
W. Krakow ◽  
W. C. Nixon

The scanning electron microscope (SEM) can be run at television scanning rates and used with a video tape recorder to observe dynamic specimen changes. With a conventional tungsten source, a low noise TV image is obtained with a field of view sufficient to cover the area of the specimen to be recorded. Contrast and resolution considerations have been elucidated and many changing specimens have been studied at TV rates.To extend the work on measuring the magnitude of charge and field distributions of small particles in the SEM, we have investigated their motion and electrostatic interaction at TV rates. Fig. 1 shows a time sequence of polystyrene spheres on a conducting grating surface inclined to the microscope axis. In (la) there are four particles present in the field of view, while in (lb) a fifth particle has moved into view.


Author(s):  
M. G. Lagally

It has been recognized since the earliest days of crystal growth that kinetic processes of all Kinds control the nature of the growth. As the technology of crystal growth has become ever more refined, with the advent of such atomistic processes as molecular beam epitaxy, chemical vapor deposition, sputter deposition, and plasma enhanced techniques for the creation of “crystals” as little as one or a few atomic layers thick, multilayer structures, and novel materials combinations, the need to understand the mechanisms controlling the growth process is becoming more critical. Unfortunately, available techniques have not lent themselves well to obtaining a truly microscopic picture of such processes. Because of its atomic resolution on the one hand, and the achievable wide field of view on the other (of the order of micrometers) scanning tunneling microscopy (STM) gives us this opportunity. In this talk, we briefly review the types of growth kinetics measurements that can be made using STM. The use of STM for studies of kinetics is one of the more recent applications of what is itself still a very young field.


Author(s):  
A. V. Crewe ◽  
J. Wall ◽  
L. M. Welter

A scanning microscope using a field emission source has been described elsewhere. This microscope has now been improved by replacing the single magnetic lens with a high quality lens of the type described by Ruska. This lens has a focal length of 1 mm and a spherical aberration coefficient of 0.5 mm. The final spot size, and therefore the microscope resolution, is limited by the aberration of this lens to about 6 Å.The lens has been constructed very carefully, maintaining a tolerance of + 1 μ on all critical surfaces. The gun is prealigned on the lens to form a compact unit. The only mechanical adjustments are those which control the specimen and the tip positions. The microscope can be used in two modes. With the lens off and the gun focused on the specimen, the resolution is 250 Å over an undistorted field of view of 2 mm. With the lens on,the resolution is 20 Å or better over a field of view of 40 microns. The magnification can be accurately varied by attenuating the raster current.


Author(s):  
A.M.H. Schepman ◽  
J.A.P. van der Voort ◽  
J.E. Mellema

A Scanning Transmission Electron Microscope (STEM) was coupled to a small computer. The system (see Fig. 1) has been built using a Philips EM400, equipped with a scanning attachment and a DEC PDP11/34 computer with 34K memory. The gun (Fig. 2) consists of a continuously renewed tip of radius 0.2 to 0.4 μm of a tungsten wire heated just below its melting point by a focussed laser beam (1). On-line operation procedures were developped aiming at the reduction of the amount of radiation of the specimen area of interest, while selecting the various imaging parameters and upon registration of the information content. Whereas the theoretical limiting spot size is 0.75 nm (2), routine resolution checks showed minimum distances in the order 1.2 to 1.5 nm between corresponding intensity maxima in successive scans. This value is sufficient for structural studies of regular biological material to test the performance of STEM over high resolution CTEM.


Sign in / Sign up

Export Citation Format

Share Document