Use of a Geiger-Müller Counter for the Study of the Diffraction of X-Rays by a Gas

Nature ◽  
1936 ◽  
Vol 137 (3468) ◽  
pp. 657-657 ◽  
Author(s):  
W. VAN DER GRINTEN ◽  
H. BRASSEUR
Keyword(s):  
X Rays ◽  
1991 ◽  
Vol 6 (3) ◽  
pp. 126-129
Author(s):  
Donald P. LeGalley

The design and construction of Geiger-Müller counters which will respond reliably to Mo K x-rays is described. The impulses are amplified and recorded mechanically with the aid of a thyratron circuit. The amplifying and counting circuit, and the counting mechanism, are also described. The time of recovery of the counters has been determined by the use of an oscillograph and found to be less than 0.001 sec. when the proper values are used for the resistance and capacitance of the counter circuit. It is shown that for counting rates up to 600 per minute there is less than a 1 percent correction due to the fact that the impulses are random in nature. Several fundamental tests are described, which have been applied to the counter and the circuit. These tests have shown the counter and the circuit to be a reliable method of measuring x-ray intensities. Graphs are shown of the diffraction patterns of NaCl and KC1 taken by means of the counters. These graphs duplicate the well-known diffraction patterns of these materials, thus giving additional evidence of the reliability of the counters.


1998 ◽  
Vol 4 (S2) ◽  
pp. 162-163
Author(s):  
Kurt F. J. Heinrich

In February 1968 Ray Fitzgerald, Klaus Keil and myself published in Science a communication titled “Solid-State Energy-Dispersion Spectrometer for Electron Microprobe X-ray Analysis”. The authors describe the use of a lithium-drifted silicon detector for the direct identification of x-rays, without a diffracting crystal, in an electron probe. The subject of this paper was to modify profoundly the development of x-ray microanalysis in the years to follow.Pulse-height analysis of gamma rays detected in scintillation counters was widely used at the time. For radiation of energies below 30 keV, gas proportional counters were also employed. In elementary analysis by x-rays the poor energy resolution of these detectors limited the application of such a procedure, although single-channel pulse height analysis was employed as an adjunct to crystal spectrometers.In 1951, Raymond Castaing in his thesis described his invention of the electron probe microanalyzer, created by adding to a transmission electron microscope a curved-crystal spectrometer which focused the x-rays emitted by the specimen into a Geiger-Muller counter.


1994 ◽  
Vol 144 ◽  
pp. 82
Author(s):  
E. Hildner

AbstractOver the last twenty years, orbiting coronagraphs have vastly increased the amount of observational material for the whitelight corona. Spanning almost two solar cycles, and augmented by ground-based K-coronameter, emission-line, and eclipse observations, these data allow us to assess,inter alia: the typical and atypical behavior of the corona; how the corona evolves on time scales from minutes to a decade; and (in some respects) the relation between photospheric, coronal, and interplanetary features. This talk will review recent results on these three topics. A remark or two will attempt to relate the whitelight corona between 1.5 and 6 R⊙to the corona seen at lower altitudes in soft X-rays (e.g., with Yohkoh). The whitelight emission depends only on integrated electron density independent of temperature, whereas the soft X-ray emission depends upon the integral of electron density squared times a temperature function. The properties of coronal mass ejections (CMEs) will be reviewed briefly and their relationships to other solar and interplanetary phenomena will be noted.


2000 ◽  
Vol 179 ◽  
pp. 263-264
Author(s):  
K. Sundara Raman ◽  
K. B. Ramesh ◽  
R. Selvendran ◽  
P. S. M. Aleem ◽  
K. M. Hiremath

Extended AbstractWe have examined the morphological properties of a sigmoid associated with an SXR (soft X-ray) flare. The sigmoid is cospatial with the EUV (extreme ultra violet) images and in the optical part lies along an S-shaped Hαfilament. The photoheliogram shows flux emergence within an existingδtype sunspot which has caused the rotation of the umbrae giving rise to the sigmoidal brightening.It is now widely accepted that flares derive their energy from the magnetic fields of the active regions and coronal levels are considered to be the flare sites. But still a satisfactory understanding of the flare processes has not been achieved because of the difficulties encountered to predict and estimate the probability of flare eruptions. The convection flows and vortices below the photosphere transport and concentrate magnetic field, which subsequently appear as active regions in the photosphere (Rust & Kumar 1994 and the references therein). Successive emergence of magnetic flux, twist the field, creating flare productive magnetic shear and has been studied by many authors (Sundara Ramanet al.1998 and the references therein). Hence, it is considered that the flare is powered by the energy stored in the twisted magnetic flux tubes (Kurokawa 1996 and the references therein). Rust & Kumar (1996) named the S-shaped bright coronal loops that appear in soft X-rays as ‘Sigmoids’ and concluded that this S-shaped distortion is due to the twist developed in the magnetic field lines. These transient sigmoidal features tell a great deal about unstable coronal magnetic fields, as these regions are more likely to be eruptive (Canfieldet al.1999). As the magnetic fields of the active regions are deep rooted in the Sun, the twist developed in the subphotospheric flux tube penetrates the photosphere and extends in to the corona. Thus, it is essentially favourable for the subphotospheric twist to unwind the twist and transmit it through the photosphere to the corona. Therefore, it becomes essential to make complete observational descriptions of a flare from the magnetic field changes that are taking place in different atmospheric levels of the Sun, to pin down the energy storage and conversion process that trigger the flare phenomena.


Author(s):  
R. F. Bils ◽  
W. F. Diller ◽  
F. Huth

Phosgene still plays an important role as a toxic substance in the chemical industry. Thiess (1968) recently reported observations on numerous cases of phosgene poisoning. A serious difficulty in the clinical handling of phosgene poisoning cases is a relatively long latent period, up to 12 hours, with no obvious signs of severity. At about 12 hours heavy lung edema appears suddenly, however changes can be seen in routine X-rays taken after only a few hours' exposure (Diller et al., 1969). This study was undertaken to correlate these early changes seen by the roengenologist with morphological alterations in the lungs seen in the'light and electron microscopes.Forty-two adult male and female Beagle dogs were selected for these exposure experiments. Treated animals were exposed to 94.5-107-5 ppm phosgene for 10 min. in a 15 m3 chamber. Roentgenograms were made of the thorax of each animal before and after exposure, up to 24 hrs.


Author(s):  
R. H. Duff

A material irradiated with electrons emits x-rays having energies characteristic of the elements present. Chemical combination between elements results in a small shift of the peak energies of these characteristic x-rays because chemical bonds between different elements have different energies. The energy differences of the characteristic x-rays resulting from valence electron transitions can be used to identify the chemical species present and to obtain information about the chemical bond itself. Although these peak-energy shifts have been well known for a number of years, their use for chemical-species identification in small volumes of material was not realized until the development of the electron microprobe.


Author(s):  
E. A. Kenik ◽  
J. Bentley

Cliff and Lorimer (1) have proposed a simple approach to thin foil x-ray analy sis based on the ratio of x-ray peak intensities. However, there are several experimental pitfalls which must be recognized in obtaining the desired x-ray intensities. Undesirable x-ray induced fluorescence of the specimen can result from various mechanisms and leads to x-ray intensities not characteristic of electron excitation and further results in incorrect intensity ratios.In measuring the x-ray intensity ratio for NiAl as a function of foil thickness, Zaluzec and Fraser (2) found the ratio was not constant for thicknesses where absorption could be neglected. They demonstrated that this effect originated from x-ray induced fluorescence by blocking the beam with lead foil. The primary x-rays arise in the illumination system and result in varying intensity ratios and a finite x-ray spectrum even when the specimen is not intercepting the electron beam, an ‘in-hole’ spectrum. We have developed a second technique for detecting x-ray induced fluorescence based on the magnitude of the ‘in-hole’ spectrum with different filament emission currents and condenser apertures.


Author(s):  
C.W. Akey ◽  
M. Szalay ◽  
S.J. Edelstein

Three methods of obtaining 20 Å resolution in sectioned protein crystals have recently been described. They include tannic acid fixation, low temperature embedding and grid sectioning. To be useful for 3-dimensional reconstruction thin sections must possess suitable resolution, structural fidelity and a known contrast. Tannic acid fixation appears to satisfy the above criteria based on studies of crystals of Pseudomonas cytochrome oxidase, orthorhombic beef liver catalase and beef heart F1-ATPase. In order to develop methods with general applicability, we have concentrated our efforts on a trigonal modification of catalase which routinely demonstrated a resolution of 40 Å. The catalase system is particularly useful since a comparison with the structure recently solved with x-rays will permit evaluation of the accuracy of 3-D reconstructions of sectioned crystals.Initially, we re-evaluated the packing of trigonal catalase crystals studied by Longley. Images of the (001) plane are of particular interest since they give a projection down the 31-screw axis in space group P3121. Images obtained by the method of Longley or by tannic acid fixation are negatively contrasted since control experiments with orthorhombic catalase plates yield negatively stained specimens with conditions used for the larger trigonal crystals.


Author(s):  
C. W. Mehard ◽  
W. L. Epstein

The underlying cause of a disease may not he readily apparent but may have a long history in development. We report one such case which was diagnosed with the aid of the analytical electron microscope.The patient, a 48 yr. old white female, developed a tender nodule on the sole of her foot in December, 1981. Subsequently additional lesions developed on the same foot resulting in deep pain and tenderness. Superficial lesions also extended up to the knee on both legs. No abnormalities were revealed in blood tests or chest X-rays.


Sign in / Sign up

Export Citation Format

Share Document