scholarly journals Precisely printable and biocompatible silk fibroin bioink for digital light processing 3D printing

2018 ◽  
Vol 9 (1) ◽  
Author(s):  
Soon Hee Kim ◽  
Yeung Kyu Yeon ◽  
Jung Min Lee ◽  
Janet Ren Chao ◽  
Young Jin Lee ◽  
...  
2018 ◽  
Vol 9 (1) ◽  
Author(s):  
Soon Hee Kim ◽  
Yeung Kyu Yeon ◽  
Jung Min Lee ◽  
Janet Ren Chao ◽  
Young Jin Lee ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3887
Author(s):  
Watcharapong Pudkon ◽  
Chavee Laomeephol ◽  
Siriporn Damrongsakkul ◽  
Sorada Kanokpanont ◽  
Juthamas Ratanavaraporn

Three-dimensional (3D) printing is regarded as a critical technology in material engineering for biomedical applications. From a previous report, silk fibroin (SF) has been used as a biomaterial for tissue engineering due to its biocompatibility, biodegradability, non-toxicity and robust mechanical properties which provide a potential as material for 3D-printing. In this study, SF-based hydrogels with different formulations and SF concentrations (1–3%wt) were prepared by natural gelation (SF/self-gelled), sodium tetradecyl sulfate-induced (SF/STS) and dimyristoyl glycerophosphorylglycerol-induced (SF/DMPG). From the results, 2%wt SF-based (2SF) hydrogels showed suitable properties for extrusion, such as storage modulus, shear-thinning behavior and degree of structure recovery. The 4-layer box structure of all 2SF-based hydrogel formulations could be printed without structural collapse. In addition, the mechanical stability of printed structures after three-step post-treatment was investigated. The printed structure of 2SF/STS and 2SF/DMPG hydrogels exhibited high stability with high degree of structure recovery as 70.4% and 53.7%, respectively, compared to 2SF/self-gelled construct as 38.9%. The 2SF/STS and 2SF/DMPG hydrogels showed a great potential to use as material for 3D-printing due to its rheological properties, printability and structure stability.


2021 ◽  
Author(s):  
Alexey Pustovarenko ◽  
Beatriz Seoane ◽  
Edy Abou-Hamad ◽  
Helen E King ◽  
Bert Weckhuysen ◽  
...  

3D printing, also known as additive manufacturing technology, has greatly expanded across multiple sectors of technology replacing classical manufacturing methods by combining processing speed and high precision. The scientific interest...


Polymers ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 822
Author(s):  
Jy-Jiunn Tzeng ◽  
Tzu-Sen Yang ◽  
Wei-Fang Lee ◽  
Hsuan Chen ◽  
Hung-Ming Chang

In this study, five urethane acrylates (UAs), namely aliphatic urethane hexa-acrylate (87A), aromatic urethane hexa-acrylate (88A), aliphatic UA (588), aliphatic urethane triacrylate diluted in 15% HDD (594), and high-functional aliphatic UA (5812), were selected to formulate five UA-based photopolymer resins for digital light processing (DLP)-based 3D printing. Each UA (40 wt%) was added and blended homogenously with ethoxylated pentaerythritol tetraacrylate (40 wt%), isobornyl acrylate (12 wt%), diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide (3 wt%), and a pink acrylic (5 wt%). Each UA-based resin specimen was designed using CAD software and fabricated using a DLP 3D printer to specific dimensions. Characteristics, mechanical properties, and cytotoxicity levels of these designed UA-based resins were investigated and compared with a commercial 3D printing denture base acrylic resin (BB base) control group at different UV exposure times. Shore hardness-measurement data and MTT assays were analyzed using a one-way analysis of variance with Bonferroni’s post hoc test, whereas viscosity, maximum strength, and modulus were analyzed using the Kruskal–Wallis test (α = 0.05). UA-based photopolymer resins with tunable mechanical properties were successfully prepared by replacing the UA materials and the UV exposure times. After 15 min of UV exposure, the 5812 and 594 groups exhibited higher viscosities, whereas the 88A and 87A groups exhibited lower viscosities compared with the BB base group. Maximum flexural strength, flexural modulus, and Shore hardness values also revealed significant differences among materials (p < 0.001). Based on MTT assay results, the UA-based photopolymer resins were nontoxic. In the present study, mechanical properties of the designed photopolymer resins could be adjusted by changing the UA or UV exposure time, suggesting that aliphatic urethane acrylate has good potential for use in the design of printable resins for DLP-type 3D printing in dental applications.


2021 ◽  
Author(s):  
Kankan Swargiary ◽  
Romuald Jolivot ◽  
Waleed Soliman Mohammed

AbstractA polymer based horizontal single step waveguide for the sensing of alcohol is developed and analyzed. The waveguide is fabricated by 3-dimensional (3D) printing digital light processing (DLP) technology using monocure 3D rapid ultraviolet (UV) clear resin with a refractive index of n = 1.50. The fabricated waveguide is a one-piece tower shaped ridge structure. It is designed to achieve the maximum light confinement at the core by reducing the effective refractive index around the cladding region. With the surface roughness generated from the 3D printing DLP technology, various waveguides with different gap sizes are printed. Comparison is done for the different gap waveguides to achieve the minimum feature gap size utilizing the light re-coupling principle and polymer swelling effect. This effect occurs due to the polymer-alcohol interaction that results in the diffusion of alcohol molecules inside the core of the waveguide, thus changing the waveguide from the leaky type (without alcohol) to the guided type (with alcohol). Using this principle, the analysis of alcohol concentration performing as a larger increase in the transmitted light intensity can be measured. In this work, the sensitivity of the system is also compared and analyzed for different waveguide gap sizes with different concentrations of isopropanol alcohol (IPA). A waveguide gap size of 300 µm gives the highest increase in the transmitted optical power of 65% when tested with 10 µL (500 ppm) concentration of IPA. Compared with all other gaps, it also displays faster response time (t = 5 seconds) for the optical power to change right after depositing IPA in the chamber. The measured limit of detection (LOD) achieved for 300 µm is 0.366 µL. In addition, the fabricated waveguide gap of 300 µm successfully demonstrates the sensing limit of IPA concentration below 400 ppm which is considered as an exposure limit by “National Institute for Occupational Safety and Health”. All the mechanical mount and the alignments are done by 3D printing fused deposition method (FDM).


Sign in / Sign up

Export Citation Format

Share Document