Lewis acid induced spectral changes of sterically hindered and unhindered meso-tetra(aryl)porphyrins: fluorescence emission spectra

2020 ◽  
Vol 44 (7) ◽  
pp. 3028-3037
Author(s):  
Aida G. Mojarrad ◽  
Saeed Zakavi

Fluorescence spectra of a series of electron-rich and electron-deficient meso-tetra(aryl)porphyrins and their molecular complexes with DDQ, TCNE and BF3 were investigated and compared. In spite of the great resemblance between the absorption spectra of the molecular complexes, large differences were observed between their emission spectra.

2018 ◽  
Vol 55 (1) ◽  
pp. 63-67
Author(s):  
Monica Florentina Raduly ◽  
Valentin Raditoiu ◽  
Alina Raditoiu ◽  
Luminita Eugenia Wagner ◽  
Viorica Amariutei ◽  
...  

The seven curcumin derivatives were deposited on palygorskite in order to obtain hybrid materials. The fluorescence emission spectra of the obtained materials show a decrease in fluorescence intensity relative to the respective dyes, due to the environments around the dyestuff molecules created in the host matrices. Absorption studies show the best adsorption on the inorganic matrix, for the compounds with the hydroxyl groups. Correlating fluorescence spectra of hybrid materials with the results for absorption spectra of the dyes adsorbtion on the surface of the clay lead to the conclusion that a high percentage of the adsorbed dye had the effect of fluorescence quenching. Thus, it was confirmed that the fluorescent properties of hybrid materials depend on the interactions established between the fluorescent dyestuff and the inorganic network.


1994 ◽  
Vol 48 (4) ◽  
pp. 436-447 ◽  
Author(s):  
J. W. Hofstraat ◽  
M. J. Latuhihin

Several methods that can be applied to remove wavelength-dependent instrumental effects from fluorescence emission and excitation spectra have been investigated. Removal of such artifacts is necessary for the comparison of spectra that have been obtained on different instruments. Without correction, spectral line positions and relative intensities will be instrument-determined to a great extent. Furthermore, the application of adequate correction procedures provides excitation spectra which can be directly compared to absorption spectra; comparison of corrected excitation spectra and absorption spectra can be used to interpret the efficiency and pathways of radiative processes. Finally, corrected reflection spectra can be obtained, which can be directly transformed into absorption spectra and are useful for remote sensing applications. The methods that have been studied for the correction of emission spectra are the application of a standard lamp with calibrated spectral output and the use of fluorescence standards. The standards are a series of luminescent phosphors in polymer films and a solution of quinine sulfate dihydrate in perchloric acid, all provided with certified spectral emission values. For correction of excitation spectra, a quantum counter was applied. Several quantum counters were investigated. The best results were obtained for application of a mixture of the dyes basic blue and HITC, which provided good correction for the wavelength range 250 to 820 nm. No good quantum counters have been reported thus far for this (large) wavelength range. Correction for wavelength dependence of the excitation optics was realized by measurement of the excitation light intensity at the sample position and at the reference position with a Si photodiode. Correction factors for the excitation spectra were checked with a number of reference materials. Attention has also been paid to polarization-dependent effects that may occur in fluorescence spectra. The application of correction procedures was demonstrated for phytoplankton fluorescence spectra.


F1000Research ◽  
2019 ◽  
Vol 2 ◽  
pp. 82
Author(s):  
Saurabh Gautam ◽  
Munishwar N Gupta

Direct comparison between fluorescence spectra of a sample in solution and solid state form is valuable to monitor the changes in protein structure when it is “dried” or immobilized on a solid surface (for biocatalysis or sensor applications). We describe here a simple method for recording fluorescence emission spectra of protein powders without using any dedicated accessory for solid samples in a high-throughput format. The 96-well plate used in our studies, was coated black from all the sides and the excitation and emission paths are identical and are from the top of the well. These two features minimize scatter and provide fairly noise free spectra. Even then the fluorescence intensity may be dependent upon many factors such as the extent of protein aggregation, morphology and sizes of the protein particles. Hence, (changes in) λmax emission may be a more reliable metric in the case of fluorescence spectra of proteins in the solid state. However, any large changes in the intensity could indicate changes in the microenvironment of the fluorophore. The fluorescence emission spectra were blue-shifted (4 to 9 nm), showed an increase in the intensity for different proteins studied upon lyophilization, and were similar to what has been reported by others using available commercial accessories for solid state samples. After validating that our method worked just as well as the dedicated accessories, we applied the method to compare the fluorescence emission spectra of α-chymotrypsin in solution, precipitated form, and the lyophilized powder form. We further examined the fluorescence emission spectra of green fluorescent protein (GFP) in solution and solid form. We also analyzed fluorescence resonance energy transfer (FRET) between tryptophan (Trp57) and the cyclic chromophore of GFP. These findings pointed towards the change in the microenvironment around the cyclic chromophore in GFP upon lyophilization.


F1000Research ◽  
2013 ◽  
Vol 2 ◽  
pp. 82
Author(s):  
Saurabh Gautam ◽  
Munishwar N Gupta

A simple method to determine fluorescence emission spectra of proteins in solid state is described. The available commercial accessories can only accommodate solid samples and hence do not allow a direct comparison between fluorescence spectra of a sample in solution and solid state form. Such comparisons are valuable to monitor the changes in protein structure when it is “dried” or immobilized on a solid surface (for biocatalysis or sensor applications). The commercially available accessories also do not allow working in a high throughput mode. We describe here a simple method for recording fluorescence emission spectra of protein powders without using any dedicated accessory for solid samples. This method works with a 96-well plate format. It enables the comparison of fluorescence spectra of a sample in a solid state with solution spectra, using comparable quantities of protein. The fluorescence emission spectra were blue-shifted (4 to 9 nm), showed an increase in the intensity for different proteins studied upon lyophilization, and were similar to what has been reported by others using available commercial accessories for solid state samples. After validating that our method worked just as well as the dedicated accessories, we applied the method to compare the fluorescence emission spectra of α-chymotrypsin in solution, precipitated form and the lyophilized powder form. α-Chymotrypsin in solution showed a λmax of 335 nm while a high-activity preparation of the same enzyme for non-aqueous media, known as enzyme precipitated and rinsed with propanol (EPRP), showed an increase in the intensity of the fluorescence emission spectra. However, there was a small red shift of 2 nm (λmax of 337 nm) in contrast to lyophilized powder which showed a λmax of 328 nm. This is due to a difference in the tertiary structure of the protein as well as the microenvironment of aromatic residues between the two preparations. We further examined the fluorescence emission spectra of green fluorescent protein (GFP) in solution and solid form. The relative fluorescence intensity of lyophilized GFP powder was decreased significantly to 17% as compared to GFP in solution, and showed a red shift of 4 nm in the emission λmax. It was found that fluorescence resonance energy transfer (FRET) between tryptophan (Trp57) and the cyclic chromophore of GFP was significantly diminished. This indicated the change in the microenvironment around the cyclic chromophore in GFP upon lyophilization.


2018 ◽  
Vol 31 (4) ◽  
pp. 58-62
Author(s):  
José Martínez Mendoza ◽  
Alejandra Nieto-Villena ◽  
José Angel De la Cruz-Mendoza ◽  
Gerardo Ortega-Zarzosa ◽  
Azdrubal Guerrero-Serrano

Degradation of paper through time can be measured by monitoring the intensity changes in the band located at 620 nm of its emission fluorescence spectra. The behavior of this band is closely related to the structural stability of the short cellulose chains. A fast degradation of these cellulose chains, mainly lignin, translates in the rapid denaturation of paper occurring at its first aging state. This work proposes a method to reincorporate short cellulose chains in the structure of aged paper through its immersion during 24 h in a solution based on ethyl alcohol and extracts of wood pieces. Results of fluorescence spectra measurements indicate that the short cellulose chains in the solution get embedded in the old paper, making the shape and intensity of the fluorescence emission spectra peaks of new and old paper almost indistinguishable. This behavior provides a desirable approach to analyze, preserve and restore aged paper documents.


2015 ◽  
Vol 1104 ◽  
pp. 131-135
Author(s):  
Hua Liu ◽  
Lin Lu ◽  
Dun Jia Wang

Three 2,6-bis (1,3,4-oxadiazol-2-yl) pyridine derivatives were synthesized and their structures were conformed by1H NMR, FTIR, MS techniques and elemental analysis. The UV–Vis absorption and fluorescence emission spectra of these compounds were investigated in chloroform solution. The results showed that these bis-1,3,4-oxadiazole derivatives had broad and strong absorption at 278−302 nm in the UV–Vis spectra and exhibited fluorescence emission at 338 −367 nm under UV illumination in fluorescence spectra. It was found that the nature of the substituents at benzene ring in bis-1,3,4-oxadiazole derivatives had a significant impact on their photoluminescence behaviors.


2013 ◽  
Vol 740 ◽  
pp. 560-564
Author(s):  
Li Quan Zhang

This paper, through UV-vis absorption spectra of iron porphyrin chloride, fluorescence-emission spectra of NaOH and of DMSO, has obtained the properties of iron porphyrin chloride, and has made verification and comparison through molecular simulation method. Verification and comparison result coincide well, and this paper has made explanation to it.


2019 ◽  
Vol 29 (4) ◽  
pp. 134
Author(s):  
Mahasin F. Hadi Al-Kadhemy ◽  
Asrar Abdulmunem ◽  
Husam Sabeeh Al-Arab

For different amount of masses of TiO2 nanoparticles in dye solution, absorption and Fluorescence profiles of the suspension for TiO2 nanoparticles with Fluorescein (F) in distilled water solution, has been explored. An absorption spectra enhancement were detected for changed amount of masses, which specifies that the doping with TiO2 nanoparticles has a major effect on the dye absorption spectra. Contrarily, all fluorescence emission spectra for the dye, were quenched as TiO2 nanoparticles amount of masses increases because of Förster resonance energy transfer (FRET).


2014 ◽  
Vol 940 ◽  
pp. 11-15
Author(s):  
Jun Qin Feng ◽  
Jun Fang Chen

Zinc nitride films were deposited by ion sources-assisted magnetron sputtering with the use of Zn target (99.99% purity) on 7059 glass substrates. The films were characterized by XRD, SEM and EDS, the results of which show that the polycrystalline zinc nitride thin film can be grown on the glass substrates, the EDS spectrum confirmed the chemical composition of the films and the SEM images revealed that the zinc nitride thin films have a dense structure. Ultraviolet-visible-near infrared spectrophotometer was used to study the transmittance behaviors of zinc nitride thin films, which calculated the optical band gap by Davis Mott model. The results of the fluorescence emission spectra show the zinc nitride would be a direct band gap semiconductor material.


Sign in / Sign up

Export Citation Format

Share Document