scholarly journals Energy and hygrothermal performance of builtin mineral wool thermal insulations

2018 ◽  
Vol 163 ◽  
pp. 08001 ◽  
Author(s):  
Balázs Nagy ◽  
Tamás K. Simon

The paper analyses the monitoring measurement results on energy performance and hygrothermal behaviour of built-in rock and glass mineral wool thermal insulations in an energy efficiently refurbished typical single-family dwelling house in Hungary. The experimental monitoring measurements included an external weather station; internal air condition measurements; temperature, relative humidity and heat flux sensors in the layers of the facade and attic. An energy meter was installed into the heating systems. Apart from the insulated one, the energy consumption of an uninsulated but identical family house close by to the refurbished one was monitored as control. In the paper, apart from comparing the energy performance of the monitored buildings, the conjugated heat and moisture behaviour of the built-in mineral wool insulations were examined and compared to their design values and conditions. The temperature and moisture correction factors were evaluated. The paper presents laboratory measurements on the thermal conductivity of built-in and etalon mineral wool insulation samples also. The circumstances were set according to the experienced built-in conditions in the monitored buildings and compares the energy and hygrothermal performance of new and aged insulations.

2018 ◽  
Vol 163 ◽  
pp. 08006 ◽  
Author(s):  
Balázs Nagy

Ceramic brick as building material has been used for thousands of years. Nowadays, the energy performance of new products has to meet rigorous requirements; therefore, in the design of new ceramic masonry blocks, building physical simulations are essential. The aim of this research is to evaluate existing masonry block shapes filled with different thermal insulation using conjugated heat and moisture transport finite element simulations with material properties measured in laboratory. The research compared four different internal structures: trapezoidal, triangular, rectangular, and with mixed shaped gaps according to existing masonry blocks. In the gaps, different thermal insulations were considered, such as mineral wool, expanded perlite and polyurethane foam. The research demonstrated that the perlite as filling material does not have a great effect on thermal conductivity comparing to unfilled blocks; however, polyurethane foam with an optimal internal structure can improve the thermal performance. Manufacturing inaccuracies in the materials’ hygrothermal properties influences their performance, since a little difference in thermal conductivity has a noticeable impact on thermal transmittance, and it may result in underperformance according to regulations.


2019 ◽  
Vol 9 (6) ◽  
pp. 1222 ◽  
Author(s):  
Klaus Viljanen ◽  
Xiaoshu Lu

The recent research on highly insulated structures presents controversial conclusions on risks in moisture safety. This paper addresses these controversial issues through investigating the hygrothermal performance of energy efficient envelope structures under high moisture loads. The experiments consist of built-in moisture and rain leakage tests in mineral wool insulated structures. A heat and moisture transfer simulation model is developed to examine the drying-out ability in both warm and cold seasons. The results show that the energy efficient structures have an excellent drying out ability against built-in and leakage moisture. The difference in the drying ability is limited compared to conventional structures. A critical leakage moisture amount reaching the insulation cavity for a wood frame wall is determined to be between 6.9–20.7 g in a single rain event occurring every other day. Further research is required to target highly insulated structures, particularly addressing water vapor diffusion and convection.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3311
Author(s):  
Víctor Pérez-Andreu ◽  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Javier Cárcel-Carrasco

The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.


2020 ◽  
Vol 13 (1) ◽  
pp. 235
Author(s):  
Fernando Martín-Consuegra ◽  
Fernando de Frutos ◽  
Ignacio Oteiza ◽  
Carmen Alonso ◽  
Borja Frutos

This study quantified the improvement in energy efficiency following passive renovation of the thermal envelope in highly inefficient residential complexes on the outskirts of the city of Madrid. A case study was conducted of a single-family terrace housing, representative of the smallest size subsidized dwellings built in Spain for workers in the nineteen fifties and sixties. Two units of similar characteristics, one in its original state and the other renovated, were analyzed in detail against their urban setting with an experimental method proposed hereunder for simplified, minimal monitoring. The dwellings were compared on the grounds of indoor environment quality parameters recorded over a period covering both winter and summer months. That information was supplemented with an analysis of the energy consumption metered. The result was a low-cost, reasonably accurate measure of the improvements gained in the renovated unit. The monitoring output data were entered in a theoretical energy efficiency model for the entire neighborhood to obtain an estimate of the potential for energy savings if the entire urban complex were renovated.


2021 ◽  
pp. 174425912110560
Author(s):  
Yassine Chbani Idrissi ◽  
Rafik Belarbi ◽  
Mohammed Yacine Ferroukhi ◽  
M’barek Feddaoui ◽  
Driss Agliz

Hygrothermal properties of building materials, climatic conditions and energy performance are interrelated and have to be considered simultaneously as part of an optimised building design. In this paper, a new approach to evaluate the energy consumption of residential buildings in Morocco is presented. This approach is based on the effect of coupled heat and moisture transfer in typical residential buildings and on their responses to the varied climatic conditions encountered in the country. This approach allows us to evaluate with better accuracy the response of building energy performance and the indoor comfort of building occupants. Annual energy consumption, cooling and heating energy requirements were estimated considering the six climatic zones of Morocco. Based on the results, terms related to coupled heat and moisture transfer can effectively correct the existing energy consumption calculations of the six zones of Morocco, which currently do not consider energy consumption due to coupled heat and moisture transfer.


2003 ◽  
Vol 46 (1) ◽  
pp. 66-73 ◽  
Author(s):  
Tengfang Xu

This paper presents in-situ measurement results for energy and environmental performance of 13 cleanroom systems located in the United States, including key metrics for evaluating cleanroom air system performance and overall electric power intensity. Comparisons with IEST Recommended Practice IEST-RP-CC012.1: Considerations in Cleanroom Design are made to examine the performance of cleanroom air systems. Based on the results, the paper discusses likely opportunities for improving cleanroom energy efficiency while maintaining effective contamination control. The paper concludes that there are wide variations in energy performance of cleanroom environmental systems, and that performance benchmarking can serve as a vehicle to identify energy efficient cleanroom design practices and to highlight important issues in cleanroom operation and maintenance.


2020 ◽  
Vol 29 (2) ◽  
pp. 223-233
Author(s):  
Ewa Figiel ◽  
Dorota Leciej-Pirczewska

New demands for lowering energy consumption of buildings lead to many new solutions including, amongst others, the introduction of an outer wall thermal barrier for both heating and cooling effect. The analysed thermo-active-wall-barrier is a water-based system, where the pipes are embedded in the wall construction. It enables the use of a low-temperature barrier medium for space heating, thereby increasing the efficiency of all potential energy supply systems using renewable energy sources. The pipes form an active thermal barrier for heat transfer between the outer and the heated space. There are many possibilities to place the pipes in the wall for example in the case of energetic thermo-modernisation. Our research and calculations have shown that thermo-active-wall-barrier is sensitive to the location of pipes. The following paper also provides a study of the impact of thermal barrier on a building’s energy performance. The analysis was conducted for a single-family house in a temperate climate based on parameters taken from one of the Polish meteorological data-bases. Calculations using current procedure of evaluating building energy performance show, that the thermal barrier can contribute to signifi cant reduction of transmission energy loss thus lowering the environmental impact.


2021 ◽  
Vol 13 (16) ◽  
pp. 9220
Author(s):  
Rosita Norvaišienė ◽  
Paweł Krause ◽  
Vincent Buhagiar ◽  
Arūnas Burlingis

The article presents the results of a set of hygrothermal experiments of an external wall insulated with an ETICS. As an add-on to previous studies, thermal insulation in the form of polystyrene with an additional horizontal strip of mineral wool was used. Laboratory tests were carried out in accordance with ETAG 004. The ETICS test rig was composed of combustible expanded polystyrene foam (EPS) and horizontal strips of noncombustible mineral wool (MW) fire barriers over windows. The physical and mechanical properties of four types of finishing renders (without an additional reinforcement mesh in base coat of the fire barriers) were analyzed across full hygrothermal cycles in a climate chamber. Temperature sensors were mounted onto different ETICS layers to collect thermal data during the weathering. The testing of ETICS regarding their hygrothermal performance revealed that there were no visible defects on any renderings and over the junctions depending on the type of used insulation materials. Results also showed that the joints of EPS and MW have approximately half of their bond strength from polystyrene strength.