scholarly journals F-Gas regulation-Possible solutions for the retrofit dead end

2018 ◽  
Vol 178 ◽  
pp. 09023
Author(s):  
Filipe Gonçalves ◽  
Miguel Cavique

The EU F-gas regulation of 2006 and the recast of 2014 are forcing the market to reduce the use of refrigerants with high global warming potential (GWP). As a result, the production of hydrofluorocarbon (HFC) refrigerants with higher GWP decreased, making the prices of all HFC gases to increase. Any maintenance problem in a refrigeration system asks to evaluate the retrofitting of the gas making necessary to know the expected behaviour of the system. This paper aims to discuss the gases that can substitute the now-a-days HFCs, and the impact the retrofit will cause in a real air-conditioning systems. Many studies on retrofit address the behaviour of the refrigeration cycle, but usually, do not take into account the behaviour of the system as a whole. This paper models a water-to-water air-conditioning system taking into consideration the evaporator and condenser heat exchangers, the refrigeration cycle, the air-conditioning loop and the heat exchanger to the acclimatized area. Moreover, the paper studies the performance of the system when subjected to high condensing temperatures. The paper concludes that all possible retrofit solutions need to use flammable gases that make the refrigeration power of the equipment to reduce.

Author(s):  
A. Anthony Adeyanju ◽  
K. Manohar

Thermoelectric devices use the Peltier effect which creates a heat flux between the junctions of two different types of materials. The thermoelectric module also referred to as a heat pump transfers heat from one side to the other when a DC current is applied. This study carried out the theoretical and experimental analysis of a thermoelectric air conditioning system. A prototype thermoelectric air conditioner of 286 W cooling capacity was built and a testing enclosure made from plywood and Styrofoam was also constructed in order to validate the theoretical result with an experimentation. It was discovered that thermoelectric air conditioning took 4 minutes to reach its desired temperature of 22℃ whereas the standard air conditioning system (Refrigeration Cycle) took 20 minutes to cool to a room temperature. Economically it was also discovered that thermoelectric air conditioning system is 50% cheaper than the refrigeration cycle air conditioning systems. The thermoelectric air conditioner has cheaper maintenance and greater estimated life span of 7 years more than the refrigeration air conditioner. This is because the air conditioner that operates on the refrigeration cycle uses a rotating compressor while the thermoelectric air conditioner uses thermometric module.


2012 ◽  
Vol 170-173 ◽  
pp. 2546-2549 ◽  
Author(s):  
Jian Lv ◽  
Fang Yu ◽  
Guo Min Zhao ◽  
Jun Mei Zhang ◽  
Hong Xing Yang

An experimental test has been conducted to determine the effect of heat pipe heat exchangers for pre-cooling and re-heating performance of central air-conditioning systems in Hung Hom Sport Centre. The objectives of this research project are to investigate the energy recovery efficiency from using the heat pipe heat exchangers in air conditioning system. The annual energy saving by using the heat pipe heat exchangers. The effect of energy recovery efficiency is significant.


2014 ◽  
Vol 580-583 ◽  
pp. 2441-2446
Author(s):  
Yu Na Li ◽  
Si Fu Wang ◽  
Tu Zhai Lv ◽  
Shao Fei Lang

Ice storage air-conditioning system has incomparable advantages than a lot of of conventional air-conditioning system example for "peak shifting and valley filling". The ice storage air-conditioning systems on the research states of the economic analysis are summed up from the building of economic analysis model,the introduction of the special systems , as well as the impact of economic factors in this paper. This paper outlines several main methods about economic evaluation of the ice storage air-conditioning systems,points out some issumes in the course of the study and some places needing to improve.


2011 ◽  
Vol 32 (4) ◽  
pp. 307-327 ◽  
Author(s):  
YH Yau ◽  
M Ahmadzadehtalatapeh

The effect of heat pipe heat exchanger on the heat recovery was studied in the tropics. The performance of the heat exchanger was monitored during the one week of operation (168 h) to find out the performance characteristic curves. Three coil face velocities namely, 2, 2.2 and 2.5 m/s were tested and the temperature of return air was controlled at 24°C. The relevant empirical equations were then employed for the hour-by-hour prediction of the energy recovery by the heat pipe heat exchanger for the whole year. The impact of inside design temperature on the heat recovery by the heat exchanger was also studied. The thermal performance of the heat pipe heat exchanger was simulated based on the effectiveness-NTU method and the theoretical values were compared with the experimental data. Practical application: Performance improvement of the heating, ventilating and air conditioning systems is a challenge to the designers. The results obtained from this research work could serve as a practical guide for engineers who are intending to use heat pipe heat exchangers in the heating, ventilation and air conditioning systems operating in tropical climates. Engineers and researchers have the potential to use the recommended empirical performance equations to examine the impact of heat pipe heat exchangers on the performance of the current air conditioning systems. Moreover, these empirical performance equations enable the year-round operating effect of heat pipe heat exchangers on energy savings to be predicted realistically.


2019 ◽  
Vol 6 (3) ◽  
pp. 80-85
Author(s):  
Denis Igorevich Smagin ◽  
Konstantin Igorevich Starostin ◽  
Roman Sergeevich Savelyev ◽  
Anatoly Anatolyevich Satin ◽  
Anastasiya Romanovna Neveshkina ◽  
...  

One of the ways to achieve safety and comfort is to improve on-board air conditioning systems.The use of air cooling machine determines the air pressure high level at the point of selection from the aircraft engine compressor. Because of the aircraft operation in different modes and especially in the modes of small gas engines, deliberately high stages of selection have to be used for ensuring proper operation of the refrigeration machine in the modes of the aircraft small gas engines. Into force of this, most modes of aircraft operation have to throttle the pressure of the selected stage of selection, which, together with the low efficiency of the air cycle cooling system, makes the currently used air conditioning systems energy inefficient.A key feature of the architecture without air extraction from the main engines compressors is the use of electric drive compressors as a source of compressed air.A comparative analysis of competing variants of on-board air conditioning system without air extraction from engines for longrange aircraft projects was performed at the Moscow Aviation Institute (National Research University).The article deals with the main approaches to the decision-making process on the appearance of a promising aircraft on-board air conditioning system at the stage of its conceptual design and formulated the basic requirements for the structure of a complex criterion at different life cycle stages.The level of technical and technological risk, together with a larger installation weight, will require significant costs for development, testing, debugging and subsequent implementation, but at the same time on-board air conditioning system scheme without air extraction from the engines will achieve a significant increase in fuel efficiency at the level of the entire aircraft.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


1971 ◽  
Vol 93 (2) ◽  
pp. 172-176
Author(s):  
M. E. Lackey

The thermal energy requirements for air conditioning by compressive and absorption methods were determined for light-water, thermal-breeder, and fast-breeder reactors. The energy required to produce a ton-hour of refrigeration varied from 5100 Btu to 13,100 Btu by absorption and from 5600 to 8800 Btu by compression. The amount of waste heat dissipated to the environment at the reactor site as a consequence of producing a ton-hour of air conditioning ranged from an increase of 21,000 Btu for the electric-motor-driven refrigeration system to a decrease of 6000 Btu for the absorption refrigeration system.


2005 ◽  
Vol 16 (4) ◽  
pp. 59-66 ◽  
Author(s):  
V Mittal ◽  
KS Kasana ◽  
NS Thakur

An air-conditioning system utilizing solar energy would generally be more efficient, cost wise, if it was used to provide both heating and cooling requirements in the building it serves. Various solar powered heating systems have been tested extensively, but solar powered air conditioning systems have received very little attention. Solar powered absorption cooling systems can serve both heating and cooling requirements in the building it serves. Many researchers have studied the solar absorption air conditioning system in order to make it economically and technically viable. But still, much more research in this area is needed. This paper will help many researchers working in this area and provide them with fundamental knowledge on absorption systems, and a detailed review on the past efforts in the field of solar absorption cooling systems with the absorption pair of lithium-bromide and water. This knowledge will help them to start the parametric study in order to investigate the influence of key parameters on the overall system performance.