ANALYSIS OF COMPETING VARIANTS OF AIR CONDITIONING SYSTEMS WITHOUT AIR EXTRACTION FROM ENGINES AT THE STAGE OF PASSENGER AIRCRAFT ONBOARD SYSTEMS CONCEPTUAL DESIGN

2019 ◽  
Vol 6 (3) ◽  
pp. 80-85
Author(s):  
Denis Igorevich Smagin ◽  
Konstantin Igorevich Starostin ◽  
Roman Sergeevich Savelyev ◽  
Anatoly Anatolyevich Satin ◽  
Anastasiya Romanovna Neveshkina ◽  
...  

One of the ways to achieve safety and comfort is to improve on-board air conditioning systems.The use of air cooling machine determines the air pressure high level at the point of selection from the aircraft engine compressor. Because of the aircraft operation in different modes and especially in the modes of small gas engines, deliberately high stages of selection have to be used for ensuring proper operation of the refrigeration machine in the modes of the aircraft small gas engines. Into force of this, most modes of aircraft operation have to throttle the pressure of the selected stage of selection, which, together with the low efficiency of the air cycle cooling system, makes the currently used air conditioning systems energy inefficient.A key feature of the architecture without air extraction from the main engines compressors is the use of electric drive compressors as a source of compressed air.A comparative analysis of competing variants of on-board air conditioning system without air extraction from engines for longrange aircraft projects was performed at the Moscow Aviation Institute (National Research University).The article deals with the main approaches to the decision-making process on the appearance of a promising aircraft on-board air conditioning system at the stage of its conceptual design and formulated the basic requirements for the structure of a complex criterion at different life cycle stages.The level of technical and technological risk, together with a larger installation weight, will require significant costs for development, testing, debugging and subsequent implementation, but at the same time on-board air conditioning system scheme without air extraction from the engines will achieve a significant increase in fuel efficiency at the level of the entire aircraft.

The work is aimed to replace conventional refrigerants used in air cooling system with Air Cycle Machine (ACM). Commercial Air-conditioners uses the refrigerants (Freon-Gas cycle) to remove the indoor air from the room. Freon leakage causes health problems such as respiratory ailments, heart attack and circulatory collapse. Air conditioning systems made based on desiccants. Refrigerant poisoning results in Throat swelling, loss of vision, blood vomiting, blood in the stool, severe abdominal pain and even death is possible. This can be overcome by using air cycle cooling process instead of Freon as a phase changing material. Air Cycle Machine is the system used in aircraft cabin pressurization and cooling system which does not uses refrigerants in the cooling process. The analytical work carried out in this paper is to study the air conditioning system using Air Cycle Machine and investigate the air flow inside the room by giving the various inlet temperatures and the inlet velocity of the Air-conditioner. ANSYS-FLUENT 16.0 is used for the analytical study. A cabin enclosure was modeled and analyzed for different inlet temperatures and velocities and out coming cool air spread nature for the given conditions have been observed. The qualitative results of this study clearly evident the usage of Air Cycle Machine (ACM) is prominently reduces the room temperature than the refrigerant system and spreads the cool air throughout the enclosed room makes a comfortable environment and this would not leads to any health hazards. Thus this study is certain to use Air Cycle Machine (ACM) for the cabin cooling system rather than refrigerants.


2019 ◽  
Vol 304 ◽  
pp. 04015 ◽  
Author(s):  
Roman Savelev ◽  
Denis Smagin ◽  
Tatiana Zyazeva

Analysis of competing options for the implementation of the system is a key task at the stage of conceptual design of aviation air conditioning systems as these systems have a great impact on the fuel efficiency of the entire aircraft. The decision about choice of competing options regarding not only the appearance of the system, but also a lot of different parameters including technical, technological and so on. In case of conceptual design missing parameters for a complex criterion can be replaced by an alternative risk level estimate. This article shows an example how to compare competing variants of the air management system at the stage of conceptual design and provides a methodology for selecting the key parameters of the comparison criterion. As a result, it is shown that vapor cycle cooling is more promising due to the wide possibilities of reducing the mass of components and increasing the overall cooling efficiency. For the air cycle, most of the possible solutions to increase efficiency have already been implemented now.


Author(s):  
Anastasiya A. Frolova ◽  
◽  
Pavel I. Lukhmenev ◽  

Introduction. The air conditioning system is the main consumer of electricity inside office and shopping buildings. The coo­ling needs arise inside such buildings all over the year due to high amounts of heat emitted by people and equipment (computers, office equipment, cash registers), solar radiation (the envelopes of the majority of these buildings have continuous glazed facades) and sources of artificial lighting. A conventional cooling system has a compressor and condensers. The most important step towards an optimized and low-energy cooling system is the abandonment of compressor and condensers; in addition, the cold extracted from the outdoor air, is used in the system. This cooling technique is called an atmospheric co­oling system. The climatic features of Russia allow for a large-scale application of the cooling technology that uses natural cold. However, for a start, a decision was made to focus on a central region of the Russian Federation, namely, Moscow, rather than any northern areas of the country. Materials and methods. The problem is solved by the calculation method applied to the case of a 35-storey office building in Moscow. Various outdoor temperature options were considered as the bases for a transition to an atmospheric cooling system. The co-authors also compare different installation options for dry coolers, which in turn affect the routing length of refrigeration circuits. The annual demand for cold is calculated for all analyzed options. Results. Some results are presented in the form of tables of annual energy consumption by different types of air cooling systems. Conclusions. The co-authors have found that the location of dry coolers strongly affects the power consumption by a co­oling system. Power consumption by cooling systems was analyzed, and it was found out that transition to machine refrigeration at the higher outdoor temperature of +8 °C is more efficient from the standpoint of energy efficiency than the same transition at +5 and 0 °C.


2019 ◽  
pp. 15-19
Author(s):  
Євген Іванович Трушляков ◽  
Андрій Миколайович Радченко ◽  
Сергій Анатолійович Кантор ◽  
Веніамін Сергійович Ткаченко ◽  
Сергій Георгійович Фордуй ◽  
...  

The cold output for the heat-moisture treatment of ambient air in air conditioning systems depends on its parameters (temperature and relative humidity), which vary significantly during operation. To determine the installed (design) cooling capacity of air conditioning system chillers, it is proposed to use a reduction in fuel consumption of a power plant or cooling capacity generation following its current conditioning spending over a certain period, since both of these indicators characterize the efficiency of using the installed cooling capacities of the air conditioning system. To extend the results of the investigation to a wide range of air conditioning units, two methods were used to determine the design cooling capacity (refrigerating capacity): by the maximum annual value and by the maximum growth rate of the efficiency indicator. The first method allows choosing the design cooling capacity, which provides a maximum annual reduction in the specific fuel consumption due to air cooling or maximum cooling capacity generation, which is necessary for air cooling following current climatic conditions. The second method allows determining the minimum design (installed) cooling capacity of chillers, which provides the maximum rate of reduction in fuel consumption by the power plant and the increment in the annual cooling capacity generation following the installed cooling capacity of chillers. The efficiency of air conditioning systems was analyzed for different climatic conditions: a temperate climate using the example of Voznesensk city (Ukraine) and the subtropical climate of Nanjing city (China). It is shown that the design cooling capacity values calculated by both indicators of its use efficiency are the same for the same climatic conditions. Wherein, if to determine the design cooling capacity by both methods - by the maximum annual value and the maximum rate of growth of the indicator, its values turned out to be quite close for tropical climatic conditions and somewhat different for a temperate climate.


Author(s):  
Yilin Du ◽  
Jan Muehlbauer ◽  
Jiazhen Ling ◽  
Vikrant Aute ◽  
Yunho Hwang ◽  
...  

A rechargeable personal air-conditioning (RPAC) device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The conditioned air is discharged towards a single person through adjustable nozzle. The main focus of the current research was on the development of the cooling system. A 100 W cooling capacity prototype was designed, built, and tested. The cooling capacity of the vapor compression cycle measured was 165.6 W. The PCM was recharged in nearly 8 hours under thermosiphon mode. When this device is used in the controlled built environment, the thermostat setting can be increased so that building air conditioning energy can be saved by about 5–10%.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2005 ◽  
Vol 16 (4) ◽  
pp. 59-66 ◽  
Author(s):  
V Mittal ◽  
KS Kasana ◽  
NS Thakur

An air-conditioning system utilizing solar energy would generally be more efficient, cost wise, if it was used to provide both heating and cooling requirements in the building it serves. Various solar powered heating systems have been tested extensively, but solar powered air conditioning systems have received very little attention. Solar powered absorption cooling systems can serve both heating and cooling requirements in the building it serves. Many researchers have studied the solar absorption air conditioning system in order to make it economically and technically viable. But still, much more research in this area is needed. This paper will help many researchers working in this area and provide them with fundamental knowledge on absorption systems, and a detailed review on the past efforts in the field of solar absorption cooling systems with the absorption pair of lithium-bromide and water. This knowledge will help them to start the parametric study in order to investigate the influence of key parameters on the overall system performance.


2020 ◽  
Vol 10 (10) ◽  
pp. 3622 ◽  
Author(s):  
Adil Al-Falahi ◽  
Falah Alobaid ◽  
Bernd Epple

The electrical power consumption of refrigeration equipment leads to a significant influence on the supply network, especially on the hottest days during the cooling season (and this is besides the conventional electricity problem in Iraq). The aim of this work is to investigate the energy performance of a solar-driven air-conditioning system utilizing absorption technology under climate in Baghdad, Iraq. The solar fraction and the thermal performance of the solar air-conditioning system were analyzed for various months in the cooling season. It was found that the system operating in August shows the best monthly average solar fraction (of 59.4%) and coefficient of performance (COP) (of 0.52) due to the high solar potential in this month. Moreover, the seasonal integrated collector efficiency was 54%, providing a seasonal solar fraction of 58%, and the COP of the absorption chiller was 0.44, which was in limit, as reported in the literature for similar systems. A detailed parametric analysis was carried out to evaluate the thermal performance of the system and analyses, and the effect of design variables on the solar fraction of the system during the cooling season.


Author(s):  
Somaye A. Mohamadi ◽  
Abdulraheem J. Ahmed

<span>Despite their complexity and uncertainty, air conditioning systems should provide the optimal thermal conditions in a building. These controller systems should be adaptable to changes in environmental parameters. In most air conditioning systems, today, there are On/Off controllers or PID in more advanced types, which, due to different environmental conditions, are not optimal and cannot provide the optimal environmental conditions. Controlling thermal comfort of an air conditioning system requires estimation of thermal comfort index. In this study, fuzzy controller was used to provide thermal comfort in an air conditioning system, and neural network was used to estimate thermal comfort in the feedback path of the controller. Fuzzy controller has a good response given the non-linear features of air conditioning systems. In addition, the neural network makes it possible to use thermal comfort feedback in a real-time control.</span>


2019 ◽  
Vol 95 (3) ◽  
pp. 296-301
Author(s):  
U. A. Rakhmanin ◽  
S. E. Shibanov ◽  
Sergey V. Kozulya

Purpose of work is a compilation of data about the microflora which colonizes a split-system, with the aim of selection of sanitary-indicative microorganisms, whose presence in the sample would indicate to the need for cleaning and disinfection of split-systems. Materials and methods. In the article there were used data of five years author’s scientific inquiry, related to the prevention of respiratory diseases, associated with the usage of a local air conditioning systems. We also use the data from the literature. Results. For selection of “indicative” microorganisms, we proposed the usage of nine criteria, each of them have numeric value from 0 to 3 points (risk for health, prevalence rate of the disease, epidemiological link, speed of split system’s colonization, difficulty of cultivation, resistance in the environment, resistance to disinfectants, frequency of detection in home air conditioning systems, frequency of detection in air conditioning systems of public buildings). After the calculation Pseudomonas aeruginosa and Staphylococcus aureus received maximal score (20 points). Therefore, these two types of bacteria are indicative microorganisms. The detection of these microorganisms in split systems will indicate to the contamination of air-conditioning system. This microflora also is a criterion of cleaning and disinfection quality - presence of these microorganisms in the samples after this process will mean that the processing of air conditioning systems was performed poorly. Conclusions. Split systems are very faster colonized by conditionally pathogenic and pathogenic microflora. To prevent the possible hazard for population’s health it is necessary to develop the normative base, according to which sanitary-and-hygienic control over the split-systems working must be carried out. Proposed criteria suggest that Pseudomonas aeruginosa and Staphylococcus aureus are indicative microorganisms, and it’s identification in the air-conditioning system would mean risk for health and necessity for cleaning and disinfection.