In Vitro Validation of Phase Contrast Measurements at 3T versus 1.5T

Author(s):  
R Doeker ◽  
M Gutberlet ◽  
GP Meyer ◽  
R Noeske ◽  
R Felix ◽  
...  
Keyword(s):  
2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Gwendolyn Williams ◽  
Suraj Thyagaraj ◽  
Audrey Fu ◽  
John Oshinski ◽  
Daniel Giese ◽  
...  

Abstract Background Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases.


2017 ◽  
Vol 8 ◽  
pp. 1649-1657 ◽  
Author(s):  
Antonín Brož ◽  
Lucie Bačáková ◽  
Pavla Štenclová ◽  
Alexander Kromka ◽  
Štěpán Potocký

Diamond nanoparticles, known as nanodiamonds (NDs), possess several medically significant properties. Having a tailorable and easily accessible surface gives them great potential for use in sensing and imaging applications and as a component of cell growth scaffolds. In this work we investigate in vitro interactions of human osteoblast-like SAOS-2 cells with four different groups of NDs, namely high-pressure high-temperature (HPHT) NDs (diameter 18–210 nm, oxygen-terminated), photoluminescent HPHT NDs (diameter 40 nm, oxygen-terminated), detonation NDs (diameter 5 nm, H-terminated), and the same detonation NDs further oxidized by annealing at 450 °C. The influence of the NDs on cell viability and cell count was measured by the mitochondrial metabolic activity test and by counting cells with stained nuclei. The interaction of NDs with cells was monitored by phase contrast live-cell imaging in real time. For both types of oxygen-terminated HPHT NDs, the cell viability and the cell number remained almost the same for concentrations up to 100 µg/mL within the whole range of ND diameters tested. The uptake of hydrogen-terminated detonation NDs caused the viability and the cell number to decrease by 80–85%. The oxidation of the NDs hindered the decrease, but on day 7, a further decrease was observed. While the O-terminated NDs showed mechanical obstruction of cells by agglomerates preventing cell adhesion, migration and division, the H-terminated detonation NDs exhibited rapid penetration into the cells from the beginning of the cultivation period, and also rapid cell congestion and a rapid reduction in viability. These findings are discussed with reference to relevant properties of NDs such as surface chemical bonds, zeta potential and nanoparticle types.


1990 ◽  
Vol 76 (6) ◽  
pp. 923 ◽  
Author(s):  
Pascal Millet ◽  
William E. Collins ◽  
Claude E. Monken ◽  
Bobby G. Brown

2004 ◽  
Vol 16 (2) ◽  
pp. 226 ◽  
Author(s):  
F. Martinez-Pastor ◽  
F. Olivier ◽  
T. Spies ◽  
L. Anel ◽  
P. Bartels

Biological Resource Banks represent a potentially valuable tool for species conservation. It is, however, necessary to understand the species-specific cryopreservation process and its consequences for spermatozoa to aid in the development of assisted reproduction as a future conservation tool. The aim of this study was to assess the in vitro functionality of white rhinoceros Cerathoterium simum epididymal spermatozoa both before and after cryopreservation. Testes from a harvested white rhino bull were removed and transported at 5°C to the laboratory within 4h. The cauda epididymis was dissected out and flushed with 2mL of Tris-citrate egg yolk extender (fraction A, Biladyl, Minitüb, Germany). A 0.1mL aliquot was removed for analysis and the balance (9mL; 2mL fraction A+7mL sperm sample) mixed with an additional 27.2mL of Tris-citrate egg yolk with glycerol (fraction B, Bidadyl). The extended sample was allowed to cool to 4°C over a 6-h period before an additional 29.2mL of cooled fraction B were added (final sperm concentration=150×106mL−1). Sperm samples were loaded into 0.25-mL straws and frozen over LN2 vapor (4cm for 20min) for later assessment. Sperm straws were thawed by placing the straws in water at 37°C for 30s. Pre-freeze and post-thaw evaluations were carried out in the same manner. Media used included: HEPES for washing (20mM HEPES, 355mM sucrose, 10mM glucose, 2.5mM KOH) and HEPES saline (197mM NaCl, instead of sucrose). An aliquot was diluted with HEPES (washing) and centrifuged for 5min at 600×g; the pellet was resuspended in HEPES saline. Sperm motility (total motility %, TM;; and progressive motility %, PM) was assessed using phase contrast microscopy (×200; 37°C). Sperm plasma membrane status was assessed using the fluorescent dye, propidium iodide (50ngmL−1 in HEPES saline;; 10min, RT). Percentage of cells with plasma membranes intact (unstained;; PMI) was recorded. Mitochondrial status was assessed with the fluorescent dye, JC-1 (7.5μM in HEPES saline;; 30min, 37°C). The % of cells with an orange-stained midpiece was recorded (active mitochondria;; MIT). Resilience to hypoosmotic shock (HOS test) was assessed by diluting a sample in 100mOsm/kg HEPES saline (1:20; 15min, RT). An aliquot was stained with PI to assess plasma membrane status (HOSPMI), and the rest was fixed with formaldehyde, and % coiled tails (positive endosmosis;; HOST) was estimated using phase contrast microscopy (×400). Evaluations of PMI, MIT and HOSPMI were performed using fluorescence microscopy (×400, 450–490nm excitation filter). The results indicated that quality was good pre-freezing (TM: 60%; PMI: 86%; MIT: 100%), except for a PM value of 15%. After thawing, although there was a drop in TM (30%), there was no decrease in PM (20%). Our in vitro functional assessment indicated a loss of quality between the pre-freeze and post-thaw evaluations, but PMI and MIT maintained their pre-thaw levels (60% and 72%, respectively). The HOS test, which indicates plasma membrane integrity, decreased from the pre-freeze level (91%) to a post-thaw value of 70%. HOSTPMI was 72% pre-freeze, and decreased to 54% post-thaw. In conclusion, epididymal spermatozoa from the white rhino may retain its functionality after cryopreservation in a commerically available cryo-extender (Bidadyl). The use of assisted reproduction techniques could someday play a role in the management and conservation of the white rhinoceros and related species.


2005 ◽  
Vol 21 (5) ◽  
pp. 604-610 ◽  
Author(s):  
Joachim Lotz ◽  
Rolf Döker ◽  
Ralph Noeske ◽  
Meike Schüttert ◽  
Roland Felix ◽  
...  

1988 ◽  
Vol 254 (2) ◽  
pp. C338-C343 ◽  
Author(s):  
M. Rabinovitch ◽  
T. Bothwell ◽  
M. Mullen ◽  
B. N. Hayakawa

We developed an in vitro method of pulsating central and microvessel pulmonary artery endothelial cells that would allow us to study the effects of increased distending pressures over a prolonged period of time. Preservation of the contact-inhibited monolayer was assessed on phase contrast microscopy and, in addition, scanning and transmission electron microscopy (SEM, TEM) were used to determine whether there were alterations in the surface characteristics or intracytoplasmic organelles that suggested cellular damage. The cells used were obtained from Rambouillet lambs, age 3-5 days, anesthetized with halothane and ventilated. The endothelium was harvested from the central pulmonary artery (CPA) by scraping the luminal surface and from the microvessels (MPA) by infusing microcarrier beads 40-140 microns external diameter. After the second passage in culture, the cells were seeded onto the translucent, flexible polyvinylchloride membrane of a transducer dome and grown to confluence. The cell dome was then connected to a blank dome with an attached quartz transducer, to a reservoir, and to stainless steel bellows tubing, all filled with culture medium and affixed to a pulsation generator. By varying the height of the reservoir, the amplitude of excursion of the bellows tubing, and the rate, the cells could be pulsated at a given distending pressure and frequency. Confluent CPA endothelial cells from three lambs and MPA cells from two others were studied after pulsation at both 100/60 and 20/10 mmHg, 60 times/min for 48 h and after nonpulsation. On phase contrast light microscopy and on SEM, the cells remained confluent.(ABSTRACT TRUNCATED AT 250 WORDS)


Author(s):  
Jaehoon Seong ◽  
Woowon Jeong ◽  
Nataliya Smith ◽  
Rheal A. Towner

The morphology of adult carotid sinus and atherosclerosis are major risk factors for ischemic stroke. It has been reported that the function of carotid sinus is pressure sensing and the regulation of heart rate. Seong and colleagues reported the lifelong development of carotid sinus morphology from infancy to maturity using post-image processed digital subtraction angiograms from 36 patients, ages from newborn to 36 years old [1]. The study unveiled the substantial growth of the internal carotid artery (ICA) with aging and the development of a carotid sinus at the root of the ICA during late adolescence. However, the development of the carotid sinus with associated hemodynamics is not clearly understood yet.


2020 ◽  
Vol 27 (1) ◽  
pp. 158-163 ◽  
Author(s):  
A. Bhartiya ◽  
K. Madi ◽  
C. M. Disney ◽  
L. Courtois ◽  
A. Jupe ◽  
...  

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro, were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. This indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.


2003 ◽  
Vol 51 (1) ◽  
pp. 103-109 ◽  
Author(s):  
Ö. Uçar ◽  
T. J. Parkinson

The relationship between concentration of calcium ionophore A23187 and incubation time upon the proportion of spermatozoa undergoing acrosome reaction (AR) in vitro was investigated in rams from a commercial artificial insemination (AI) program. Two ejaculates were collected by artificial vagina from each of nine rams of three breeds (Finn Dorset, Charolais and Suffolk) aged 8-36months. Each ejaculate was diluted in a skimmed milk extender. Spermatozoa were thereafter incubated for 45 or 60min in modified Tyrode's medium (TALP) which contained either zero, 0.1 or 1.0µM/l A23187. After fixing in 10% formaldehyde, the number of spermatozoa that had undergone AR was determined by phase contrast microscopy. In pre-incubation samples, 21.3± 3.3% of spermatozoa had undergone AR. Percentages of acrosome reacted spermatozoa were significantly (P<0.001) increased after incubation with A23187. After incubation with 0.1µM/l A23187 for 45 and 60min there were 22.4±3.0% and 31.7±4.3% acrosome reacted spermatozoa, respectively. After incubation with 1.0µM/l A23187 for 45 and 60min there were 46.2±6.5% and 53.8±5.9% acrosome reacted spermatozoa, whilst corresponding numbers in control samples were 17.0±2.7% and 22.3±4.2%. There was also a significant (P<0.001) effect of individual animals upon the responses to different concentrations of A23187. These findings indicate that (i) A23187 can be used to assess the AR of ovine spermatozoa in vitro and (ii) there are effects of individual animals upon the proportion of spermatozoa undergoing AR.


Sign in / Sign up

Export Citation Format

Share Document