Seismic Retrofit of Full-Scale Substandard Extended Rectangular RC Columns through CFRP Jacketing: Test Results and Design Recommendations

2019 ◽  
Vol 23 (1) ◽  
pp. 04018071 ◽  
Author(s):  
Hamid Farrokh Ghatte ◽  
Mustafa Comert ◽  
Cem Demir ◽  
Mustafa Akbaba ◽  
Alper Ilki
2019 ◽  
Vol 85 (1(I)) ◽  
pp. 49-56 ◽  
Author(s):  
A. M. Lepikhin ◽  
V. V. Moskvichev ◽  
A. E. Burov ◽  
E. V. Aniskovich ◽  
A. P. Cherniaev ◽  
...  

The results of unique experimental studies of the strength and service life of a metal-composite high-pressure tank are presented. The goal of the study is to analyze the fracture mechanisms and evaluate the strength characteristics of the structure. The methodology included tests of full-scale samples of the tank for durability under short-term static, long-term static and cyclic loading with internal pneumatic pressure. Generalized test results and data of visual measurements, instrumental and acoustic-emission control of deformation processes, accumulation of damages and destruction of full-scale tank samples are presented. Analysis of the strength and stiffness of the structure exposed to internal pneumatic pressure is presented. The types of limiting states of the tanks have been established experimentally. Change in the stress-strain state of the tank under cyclic and prolonged static loading is considered. Specific features of the mechanisms of destruction of a metal-composite tank are determined taking into account the role of strain of the metal liner. The calculated and experimental estimates of the energy potential of destruction and the size of the area affected upon destruction of the tank are presented. Analysis of test results showed that the tank has high strength and resource characteristics that meet the requirements of the design documentation. The results of the experiments are in good agreement with the results of numerical calculations and analysis of the stress-strain state and mechanisms of destruction of the metal-composite tank.


1992 ◽  
Vol 35 (3) ◽  
pp. 977-985 ◽  
Author(s):  
K. G. Gebremedhin ◽  
J. A. Bartsch ◽  
M. C. Jorgensen

2001 ◽  
Vol 357-360 ◽  
pp. 1241-1244 ◽  
Author(s):  
M. Däumling ◽  
C.N. Rasmussen ◽  
F. Hansen ◽  
D.W.A. Willén ◽  
O.E. Schuppach ◽  
...  

2014 ◽  
Vol 488-489 ◽  
pp. 497-500
Author(s):  
You Lin Zou ◽  
Pei Yan Huang

Deem test results from the low reversed cyclic loading quasi-static test with 2 RC columns as the basic information of secant stiffness damage of the reference column and take use of the TMS instrument in the test to artificially make the damage percentage of secant stiffness of the RC column as 33%, 50% and 66%, 6 damaged columns in total; reinforce the 6 damaged columns and 2 undamaged ones under the same conditions with AFL, through quasi-static contrast test. Test results show that it is able to effectively boost horizontal ultimate bearing capacity and ductility deformability of the RC columns with AFL for reinforcement; besides, there is a linear function relationship between horizontal ultimate bearing capacity, target ductility factor, and damage percentage of secant stiffness.


Author(s):  
John Halkyard ◽  
Senu Sirnivas ◽  
Samuel Holmes ◽  
Yiannis Constantinides ◽  
Owen H. Oakley ◽  
...  

Floating spar platforms are widely used in the Gulf of Mexico for oil production. The spar is a bluff, vertical cylinder which is subject to Vortex Induced Motions (VIM) when current velocities exceed a few knots. All spars to date have been constructed with helical strakes to mitigate VIM in order to reduce the loads on the risers and moorings. Model tests have indicated that the effectiveness of these strakes is influenced greatly by details of their design, by appurtenances placed on the outside of the hull and by current direction. At this time there is limited full scale data to validate the model test results and little understanding of the mechanisms at work in strake performance. The authors have been investigating the use of CFD as a means for predicting full scale VIM performance and for facilitating the design of spars for reduced VIM. This paper reports on the results of a study to benchmark the CFD results for a truss spar with a set of model experiments carried out in a towing tank. The focus is on the effect of current direction, reduced velocity and strake pitch on the VIM response. The tests were carried out on a 1:40 scale model of an actual truss spar design, and all computations were carried out at model scale. Future study will consider the effect of external appurtenances on the hull and scale-up to full scale Reynolds’ numbers on the results.


1998 ◽  
Vol 14 (04) ◽  
pp. 265-276
Author(s):  
Ivo Senjanovic

This review paper covers extensive investigations which were undertaken in order to verify the idea of launching of ships and other floating structures from a horizontal berth by a set of turning pads. This includes structural dynamics during launching, model tests and strength analysis of the structure and the launching system. The most important results, which were used for the design of the launching system, are presented. The preparation of a barge for side launching is described, and the full-scale measurement results are compared with the test results. The advantages of building ships and offshore structures on a horizontal berth are pointed out in the conclusion.


Author(s):  
Aaron O. Akotuah ◽  
Sabah G. Ali ◽  
Jeffrey Erochko ◽  
Xia Zhang ◽  
George V. Hadjisophocleous

Connection design is critical in timber buildings since the connections tend to have lower strength than the structural members themselves and they tend to fail in a brittle manner. The effect of connection geometry on the fire performance of a hybrid steel-timber shear connection is investigated by full-scale testing. These tests were conducted by exposing the test specimens to the standard time-temperature curve defined by CAN/ULC-S101 (CAN/ULC-S101, 2007). Test results showed that the fire resistance of these connections depends on the load ratio, the type of connection and the relative exposure of the steel plate to fire. Finite element models of the connections under fire were constructed using ABAQUS/CAE and these were validated using the test results. These numerical model results correlate well with test results with ±8.32% variation.


1978 ◽  
Vol 1 (16) ◽  
pp. 38
Author(s):  
Sverre Bjordal ◽  
Alf Torum

A common method of estimating the sheltering effects of different breakwater locations and layouts is to carry out physical model wave disturbance tests. Such tests have been carried out in different laboratories throughout the world for many years. But to our knowledge no reports are available in the literature showing comparison between model measurements and field measurements. The trend is that we know more and more on the wave cl imate along our coasts. Hence we have a better basis to make our economical calculations on breakwaters. We therefore also want to operate our models on a more absolute basis rather than on a comparative basis. The trend in recent years has also been to study breakwater locations and layouts in order to minimize mooring forces and ship movements. On this background VHL found a comparison between model test results and field measurements necessary. Full scale measurements of waves were carried out in two harbours by VHL during the winter 1976/77. This paper will present the results of the comparison of the model and the full scale measurements in Berlevag and Vard0 fishing harbours on the open coast of Finnmark in the northern part of Norway (Fig. I) . The model tests, as well as the full scale measurements, have been sponsored by the Norwegian State Harbour Authorities.


Sign in / Sign up

Export Citation Format

Share Document