Collapse Assessment of Steel Moment Frames Based on E-Defense Full-Scale Shake Table Collapse Tests

2013 ◽  
Vol 139 (1) ◽  
pp. 120-132 ◽  
Author(s):  
Dimitrios G. Lignos ◽  
Tsuyoshi Hikino ◽  
Yuichi Matsuoka ◽  
Masayoshi Nakashima
2006 ◽  
Vol 22 (2) ◽  
pp. 367-390 ◽  
Author(s):  
Erol Kalkan ◽  
Sashi K. Kunnath

This paper investigates the consequences of well-known characteristics of near-fault ground motions on the seismic response of steel moment frames. Additionally, idealized pulses are utilized in a separate study to gain further insight into the effects of high-amplitude pulses on structural demands. Simple input pulses were also synthesized to simulate artificial fling-step effects in ground motions originally having forward directivity. Findings from the study reveal that median maximum demands and the dispersion in the peak values were higher for near-fault records than far-fault motions. The arrival of the velocity pulse in a near-fault record causes the structure to dissipate considerable input energy in relatively few plastic cycles, whereas cumulative effects from increased cyclic demands are more pronounced in far-fault records. For pulse-type input, the maximum demand is a function of the ratio of the pulse period to the fundamental period of the structure. Records with fling effects were found to excite systems primarily in their fundamental mode while waveforms with forward directivity in the absence of fling caused higher modes to be activated. It is concluded that the acceleration and velocity spectra, when examined collectively, can be utilized to reasonably assess the damage potential of near-fault records.


Author(s):  
Marco Miglietta ◽  
Nicolò Damiani ◽  
Gabriele Guerrini ◽  
Francesco Graziotti

AbstractTwo full-scale building specimens were tested on the shake-table at the EUCENTRE Foundation laboratories in Pavia (Italy), to assess the effectiveness of an innovative timber retrofit solution, within a comprehensive research campaign on the seismic vulnerability of existing Dutch unreinforced masonry structures. The buildings represented the end-unit of a two-storey terraced house typical of the North-Eastern Netherlands, a region affected by induced seismicity over the last few decades. This building typology is particularly vulnerable to earthquake excitation due to lack of seismic details and irregular distribution of large openings in masonry walls. Both specimens were built with the same geometry. Their structural system consisted of cavity walls, with interior load-bearing calcium-silicate leaf and exterior clay veneer, and included a first-floor reinforced concrete slab, a second-floor timber framing, and a roof timber structure supported by masonry gables. A timber retrofit was designed and installed inside the second specimen, providing an innovative sustainable, light-weight, reversible, and cost-effective technique, which could be extensively applied to actual buildings. Timber frames were connected to the interior surface of the masonry walls and completed by oriented strands boards nailed to them. The second-floor timber diaphragm was stiffened and strengthened by a layer of oriented-strand boards, nailed to the existing joists and to additional blocking elements through the existing planks. These interventions resulted also in improved wall-to-diaphragm connections with the inner leaf at both floors, while steel ties were added between the cavity-wall leaves. The application of the retrofit system favored a global response of the building with increased lateral capacities of the masonry walls. This paper describes in detail the bare and retrofitted specimens, compares the experimental results obtained through similar incremental dynamic shake-table test protocols up to near-collapse conditions, and identifies damage states and damage limits associated with displacements and deformations.


2018 ◽  
Vol 763 ◽  
pp. 259-269
Author(s):  
George Webb ◽  
Kanyakon Kosinanonth ◽  
Tushar Chaudhari ◽  
Saeid Alizadeh ◽  
Gregory A. MacRae

Beam column joint subassemblies in steel moment frames often have simply-supported gravity beams framing into the joint in the perpendicular direction. When these subassemblies undergo lateral displacement, moments enter the column from the beams. Some of these moments are directly applied from the in-plane beam and slab stresses as they contact the column, and additional moments occur as the slab causes the perpendicular simply supported beams to twist. In most design codes around the world, no explicit consideration of these moments is performed even though they may increase the likelihood of column yielding and a soft-storey mechanism. This paper quantifies the magnitude of these perpendicular beam twisting moments in typical subassemblies using inelastic finite element analysis. It is shown that for beam-column-joint-slab subassemblies where the primary and secondary beams are fully welded to the column, the addition of slab effects significantly increases the total stiffness and strength of the composite frame structure. In addition to this, it is also shown the twisting moment demand of the secondary beams increased the frames strength by approximately 2% for an imposed drift of 5% for the subassembly investigated when no gap was provided between slab and the column. It was also shown the twisting moment demand of the secondary beams increased the frames strength by approximately 10% for a maximum imposed drift of 5% for the subassembly investigated when a gap was provided between the slab and the column.


Sign in / Sign up

Export Citation Format

Share Document