Determination of Absorption Coefficient of a Solution by a Simple Experimental Setup

Author(s):  
Deepak Gopalakrishnan ◽  
C. Akhildev ◽  
P. V. Sreenivasan ◽  
K. K. Leelamma ◽  
Lyjo K. Joseph ◽  
...  
1989 ◽  
Vol 43 (1) ◽  
pp. 148-153 ◽  
Author(s):  
Dane Bićanić ◽  
Siegfried Krüger ◽  
Paul Torfs ◽  
Bruno Bein ◽  
Frans Harren

An experimental setup for performance of reverse mirage spectroscopy at CO2 laser wavelengths on liquid samples having high values of absorption coefficients is described. One and the same liquid is used as both the absorbing and deflecting medium. The Rosencwaig-Gersho theory has been applied, and the choice of experimental conditions that would enable determination of absorption coefficient β from the magnitude of photothermal signals measured at two different probe beam distances (probing locations) is discussed. The usefulness of this technique (essentially not inhibited by the requirements imposed on the sample's thickness) is tested on methanol having absorption coefficients β close to 300 cm−1 in the wavelength region covered by CO2 laser emission.


1991 ◽  
Vol 69 (3-4) ◽  
pp. 317-323 ◽  
Author(s):  
Constantinos Christofides ◽  
Andreas Mandelis ◽  
Albert Engel ◽  
Michel Bisson ◽  
Gord Harling

A photopyroelectric spectrometer with real-time and(or) self-normalization capability was used for both conventional transmission and thermal-wave spectroscopic measurements of amorphous Si thin films, deposited on crystalline Si substrates. Optical-absorption-coefficient spectra were obtained from these measurements and the superior dynamic range of the out-of-phase (quadrature) photopyroelectric signal was established as the preferred measurement method, owing to its zero-background compensation capability. An extension of a photopyroelectric theoretical model was established and successfully tested in the determination of the optical absorption coefficient and the thermal diffusivity of the sample under investigation. Instrumental sensitivity limits of βt ≈ 5 × 10−3 were demonstrated.


2013 ◽  
Vol 543 ◽  
pp. 171-175
Author(s):  
Jose Andrés Somolinos ◽  
Rafael Morales ◽  
Carlos Morón ◽  
Alfonso Garcia

In the last years, many analyses from acoustic signal processing have been used for different applications. In most cases, these sensor systems are based on the determination of times of flight for signals from every transducer. This paper presents a flat plate generalization method for impact detection and location over linear links or bars-based structures. The use of three piezoelectric sensors allow to achieve the position and impact time while the use of additional sensors lets cover a larger area of detection and avoid wrong timing difference measurements. An experimental setup and some experimental results are briefly presented.


1992 ◽  
Vol 7 (4) ◽  
pp. 194-196 ◽  
Author(s):  
Stefano Battaglia ◽  
Marco Franzini ◽  
Leonardo Leoni

AbstractThis paper describes a new method for the simultaneous determination of mineral composition, mass thickness and mass absorption coefficient of a thin layer of a crystalline substance deposited on a crystalline substrate.The samples were deposited on membrane disc filters, consisting of mixtures of cellulose acetate and cellulose nitrate. Quantitative results are achieved by measuring the diffraction intensity of the analyte and the attenuation of a reflection of the crystalline material supporting the deposited sample. The mean accuracy of the analysis was found to be: ≈ 3% for mass thickness, ≈ 1% for mass absorption coefficient and ≈ 4% for quantitative mineralogical determination.


2018 ◽  
Vol 64 (4) ◽  
pp. 407
Author(s):  
Jacqueline Isamar Muro-Ríos ◽  
R. Espinosa-Luna

Inspired in a recent theoretical work for the determination of the Mueller matrix, using as incidence a single classically entangled polarization state (F. Töppel et al., New J. Phys. 16 (2014) 073019), an experimental setup is proposed and tested.  The open space and two wave plate retarders are used as the transparent, nondepolarizing samples under study. Results show some experimental improvements are necessary in order to implement accurately the theoretical proposal in which this work is based.


Sign in / Sign up

Export Citation Format

Share Document