Can the type of preheated resin composite influence the microtensile bond strength of ceramic restoration to human dentin?

Author(s):  
Vinícius Anéas Rodrigues ◽  
Julio Nogueira Luz ◽  
Bianca Cristina Dantas da Silva ◽  
Nathalia Ramos da Silva ◽  
Marco Antonio Bottino ◽  
...  
2020 ◽  
Vol 8 (D) ◽  
pp. 112-117
Author(s):  
Ayah Atif Selim ◽  
Ahmed Fawzy Abo Elezz ◽  
Rehab Khalil Safy

AIM: Investigation of the aging effect on the microtensile bond strength (μTBS) of bulk-fill resin composite (RC) versus a conventionally incrementally applied one. MATERIALS AND METHODS: A total number of 45 sound human impacted third molars extracted molars have been selected to prepare specimens for the μTBS test. Teeth were randomly divided into three groups (C) according to type of RC material which used for restoring the teeth. Where nanohybrid RC (Grandio®SO) was used as the control Group (C1), packable bulk-fill RC (X-tra fil®) was used for restoring teeth in C2 group and flowable bulk-fill RC (X-tra base®) was used for restoring teeth in C3 group. Each group was further subdivided into 3 subgroups (n = 5) according to the water storage time, where in subgroup 1; teeth were stored for 24 h, subgroup 2; teeth were stored for 3 months while for subgroup 3; and teeth were stored for 6 months. After water storage, teeth were sectioned for preparation of μTBS testing beams. Maximum tensile stresses were recorded in megapascal (MPa). RESULTS: After 24 h of water storage, the X-tra base® showed a higher statistically significant μTBS to dentin (33.82 ± 9.84 MPa) than did the other two types of RCs. After 3 months, the X-tra fil® showed the lowest mean value of μTBS (10.90 ± 5.66 MPa), meanwhile, after 6 months of water storage Grandio®SO showed the highest mean value of μTBS (15.85 ± 6.76 MPa). Regardless of the time the X-tra fil® showed the lowest mean of μTBS (15.07 ± 11.73 MPa), while there is no significant difference between the X-tra base® and Grandio®SO. Furthermore, the water aging adversely affects μTBS values which deceased gradually by time. CONCLUSION: The packable bulk-fill RC characterized by lower μTBS to dentin in comparison to the flowable bulk fill and the incrementally applied nanohybrid RCs. Furthermore, the μTBS of the three tested materials decreased gradually by aging.


2018 ◽  
Vol 32 (21) ◽  
pp. 2405-2418 ◽  
Author(s):  
Neslihan Arhun ◽  
Derya Merve Halacoglu ◽  
Zümrüt Ceren Ozduman ◽  
Duygu Tuncer

2017 ◽  
Vol 9 (1) ◽  
pp. 38 ◽  
Author(s):  
Porntida Visuttiwattanakorn ◽  
Kallaya Suputtamongkol ◽  
Duangjai Angkoonsit ◽  
Sunattha Kaewthong ◽  
Piyanan Charoonanan

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Baraba Anja ◽  
Dukić Walter ◽  
Chieffi Nicoletta ◽  
Ferrari Marco ◽  
Sonja Pezelj Ribarić ◽  
...  

The purpose of thisin vitrostudy was to evaluate the microtensile bond strength of one-step self-etch adhesive to human dentin surface modified with air abrasion and sonic technique and to assess the morphological characteristics of the pretreated dentin surface. The occlusal enamel was removed to obtain a flat dentin surface for thirty-six human molar teeth. The teeth were randomly divided into three experimental groups (n= 12 per group), according to the pretreatment of the dentin: (1) control group, (2) air abrasion group, and (3) sonic preparation group. Microtensile bond strength test was performed on a universal testing machine. Two specimens from each experimental group were subjected to SEM examination. There was no statistically significant difference in bond strength between the three experimental groups (P> 0.05). Mean microtensile bond strength (MPa) values were 35.3 ± 12.8 for control group, 35.8 ± 13.5 for air abrasion group, and 37.7 ± 12.0 for sonic preparation group. The use of air abrasion and sonic preparation with one-step self-etch adhesive does not appear to enhance or impair microtensile bond strength in dentin.


2007 ◽  
Vol 361-363 ◽  
pp. 889-892
Author(s):  
S.Y. Kim ◽  
D.W. Kim ◽  
S.H. Park ◽  
K.K. Choi

This study was performed to investigate the bond strength between 4 dentin adhesives and resin luting cements by means of μTBS test. The materials used in this study were four resin cements (Choice, Panavia F, RelyX ARC, Bistite II DC), one 3-step adhesive (All-Bond2), one 2- step self-etching adhesive (Clearfil SE-Bond) and two 1-step self-etching adhesives(Prompt L-Pop and One-Up Bond F). Combination of 4 different dentin adhesives with 4 resin cements made up 16 experimental groups. Extracted human mandibular third molars without caries and restoratives were stored in saline and used within 1 month of extraction. All adhesive systems and resin cements were manipulated and applied to the dentin surfaces according to the manufactures’ instructions. The resin composite “overlays” prepared with 6 mm thickness (Tescera, Bisco Inc., Schaumburg, IL, USA) were luted with each resin cement. Each sample was measured μTBS. 1-step self-etching adhesives coupled with all resin luting cements used in this study resulted in lower bond strength except of OU-PA group. When Choice, RelyX ARC and Bistite II were used, Clearfil SE-Bond showed significantly higher μTBS values than 1-step self-etching adhesives (p<0.05). Clearfil SE-Bond did not show significant μTBS values than All-Bond 2 that is conventional 3-step dentin adhesive (p>0.05).


2013 ◽  
Vol 24 (4) ◽  
pp. 349-352 ◽  
Author(s):  
Regina Claudia Ramos Colares ◽  
Jiovanne Rabelo Neri ◽  
Andre Mattos Brito de Souza ◽  
Karina Matthes de Freitas Pontes ◽  
Juliano Sartori Mendonca ◽  
...  

The aim of this study was to evaluate the influence of ceramic surface treatments and silane drying temperature on the microtensile bond strength (µTBS) of a resin composite to a lithium disilicate ceramic. Twenty blocks (7x7x5 mm) of lithium disilicate-based hotpressed ceramic were fabricated and randomly divided into 4 groups: G1: acid etching with 9.5% hydrofluoric acid for 20 s and drying silane with room-temperature air; G2: acid etching with 9.5% hydrofluoric acid for 20 s and drying silane with 45 ± 5 °C warm air; G3: airborne-particle abrasion with 50 µm aluminum oxide particles and drying silane with 45 ± 5 °C warm air; G4: airborne-particle abrasion with 50 µm aluminum oxide particles and drying silane with air at room-temperature. After treatments, an adhesive system (Single Bond 2) was applied, light-cured and direct restorations were built up with a resin composite (Filtek Z250). Each specimen was stored in distilled water at 37 °C for 24 h and cut into ceramic-composite beams with 1 mm2 of cross-sectional area for µTBS testing. Statistical analysis was performed with one-way ANOVA and Student-Newman-Keuls test (α=0.05). µTBS means (S.D.) in MPa were: G1: 32.14 (7.98), G2: 35.00 (7.77) and G3: 18.36 (6.17). All specimens of G4 failed during the cutting. G1 and G2 presented significantly higher µTBS than G3 (p<0.05). There was no statistically significant difference between G1 and G2 (p>0.05). As far as the bond strength is concerned, surface pretreatment of lithium-disilicate ceramic with hydrofluoric acid and silane application can be used as an alternative to repair ceramic restorations with composite resin, while surface pretreatment with sandblasting should be avoided.


2016 ◽  
Vol 27 (4) ◽  
pp. 446-451 ◽  
Author(s):  
João Luiz Bittencourt de Abreu ◽  
Maíra Prado ◽  
Renata Antoun Simão ◽  
Eduardo Moreira da Silva ◽  
Katia Regina Hostilio Cervantes Dias

Abstract Studies have been showing a decrease of bond strength in dentin treated with sodium hypochlorite (NaOCl). The aim of this study was to evaluate the effect of non-thermal argon plasma on the bond strength of a self-etch adhesive system to dentin exposed to NaOCl. Thirty-two flat dentin surfaces of bovine incisors were immersed in 2.5% NaOCl for 30 min to simulate the irrigation step during endodontic treatment. The specimens were divided into four groups (n=8), according to the surface treatment: Control (without plasma treatment), AR15 (argon plasma for 15 s), AR30 (argon plasma for 30 s) and AR45 (argon plasma for 45 s). For microtensile bond strength test, 5 specimens were used per group. In each group, the specimens were hybridized with a self-etch adhesive system (Clearfil SE Bond) and resin composite buildups were constructed. After 48 h of water storage, specimens were sectioned into sticks (5 per tooth, 25 per group) and subjected to microtensile bond strength test (μTBS) until failure, evaluating failure mode. Three specimens per group were analyzed under FTIR spectroscopy to verify the chemical modifications produced in dentin. μTBS data were analyzed using ANOVA and Tamhane tests (p<0.05). AR30 showed the highest μTBS (20.86±9.0). AR15 (13.81±6.4) and AR45 (11.51±6.8) were statistically similar to control (13.67±8.1). FTIR spectroscopy showed that argon plasma treatment produced chemical modifications in dentin. In conclusion, non-thermal argon plasma treatment for 30 s produced chemical changes in dentin and improved the μTBs of Clearfil SE Bond to NaOCl-treated dentin.


Sign in / Sign up

Export Citation Format

Share Document