Fabrication and Characterization of Annular-Shaped Piezoelectric Micromachined Ultrasonic Transducer Mounted with Pb(Zr,Ti)O3-Based Monocrystalline Thin Film

Author(s):  
Ziyi Liu ◽  
Shinya Yoshida ◽  
Shuji Tanaka

Abstract In this study, we propose an annular-shaped piezoelectric micromachined ultrasonic transducer (pMUT) based on a Pb(Zr,Ti)O3-based monocrystalline thin film. This pMUT is expected to increase the resonance frequency while maintaining displacement sensitivity, making it superior to an island-shaped pMUT, which is a conventional design. To demonstrate the validity of this assumption, annular- and island-shaped pMUTs with a 60-μm-diameter diaphragm were prototyped and characterized. As a result, the annular-shaped pMUT exhibited a resonance frequency of 11.9 MHz, a static displacement sensitivity of 2.35 nm/V and a transmitting figure-of-merit (FOM) of 28 nm∙MHz/V. On the other hand, the island-shaped pMUT exhibited a resonance frequency of 9.6 MHz and a static displacement of 2.5 nm/V and an FOM of 24 nm∙MHz/V. Therefore, the annular-shaped pMUT was experimentally demonstrated to provide a higher FOM compared to the island-shaped pMUT. In addition, the annular-shaped pMUT with the optimal dimensions is found to be able to keep a relatively large fabrication margin. This is an advantageous point for the practical device fabrication. We believe this design has a potential to become a standard design for high-performance pMUT devices.

RSC Advances ◽  
2015 ◽  
Vol 5 (128) ◽  
pp. 106113-106121 ◽  
Author(s):  
Yangbo Huang ◽  
Haiyang Jin ◽  
Hao Li ◽  
Ping Yu ◽  
Yunbai Luo

In this study, a facile method has been developed to prepare high performance thin film composite forward osmosis membranes, which was conducted by coating the surface of a polysulfone substrate with polydopamine prior to the interfacial polymerization.


2015 ◽  
Vol 51 (59) ◽  
pp. 11777-11779 ◽  
Author(s):  
Jie Liu ◽  
Huanli Dong ◽  
Zongrui Wang ◽  
Deyang Ji ◽  
Changli Cheng ◽  
...  

The present work showed the design, synthesis and characterization of a high performance anthracene-based semiconductor.


2007 ◽  
Vol 1044 ◽  
Author(s):  
Rajeev Singh ◽  
James Christofferson ◽  
Zhixi Bian ◽  
Joachim Nurnus ◽  
Axel Schubert ◽  
...  

AbstractWe characterize several thin film thermoelectric micro-modules composed of 20 µm-thick elements and designed for cooling applications to identify factors that may limit device performance. Thermoelectric figure-of-merit measurements using the transient Harman technique are compared with maximum cooling data under no heat load. Correlation between the two measurements depending on the location of the parasitic joule heating in the module is analyzed. Near-infrared thermoreflectance is used to examine temperature non-uniformity in the module. The temperature distribution on the metal contacts due to the Peltier and Joule effects is obtained non-destructively through the silicon substrate of an active module.


RSC Advances ◽  
2016 ◽  
Vol 6 (103) ◽  
pp. 101283-101287 ◽  
Author(s):  
Pradip Kumar ◽  
Faisal Shahzad ◽  
Soon Man Hong ◽  
Chong Min Koo

We report the preparation and characterization of flexible graphene/silver nanowires (AgNWs)/graphene sandwich thin films for high-performance electromagnetic interference shielding.


Micromachines ◽  
2020 ◽  
Vol 11 (6) ◽  
pp. 623 ◽  
Author(s):  
Eunjung Shin ◽  
Hong Goo Yeo ◽  
Ara Yeon ◽  
Changzhu Jin ◽  
Wonki Park ◽  
...  

This study presents the fabrication and characterization of a piezoelectric micromachined ultrasonic transducer (pMUT; radius: 40 µm) using a patterned aluminum nitride (AlN) thin film as the active piezoelectric material. A 20 × 20 array of pMUTs using a 1 µm thick AlN thin film was designed and fabricated on a 2 × 2 mm2 footprint for a high fill factor. Based on the electrical impedance and phase of the pMUT array, the electromechanical coefficient was ~1.7% at the average resonant frequency of 2.82 MHz in air. Dynamic displacement of the pMUT surface was characterized by scanning laser Doppler vibrometry. The pressure output while immersed in water was 19.79 kPa when calculated based on the peak displacement at the resonant frequency. The proposed AlN pMUT array has potential applications in biomedical sensing for healthcare, medical imaging, and biometrics.


2015 ◽  
Vol 582 ◽  
pp. 224-228 ◽  
Author(s):  
S. Oueslati ◽  
G. Brammertz ◽  
M. Buffière ◽  
H. ElAnzeery ◽  
O. Touayar ◽  
...  

2017 ◽  
Vol 4 (11) ◽  
pp. 115304 ◽  
Author(s):  
Sabiha Sultana ◽  
Mohammad Saleem Khan ◽  
Imran Rehan ◽  
Kamran Rehan ◽  
Noor-ul- Amin ◽  
...  

2019 ◽  
Vol 66 (10) ◽  
pp. 4193-4197
Author(s):  
Wei Zhao ◽  
Yuanjie Lv ◽  
Xianjin Feng ◽  
Linan He ◽  
Hongdi Xiao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document