scholarly journals Studying the kinetics mechanism of emulsified petroleum products recovery from waste waters in dynamic conditions

2021 ◽  
Vol 1089 (1) ◽  
pp. 012030
Author(s):  
I V Starostina ◽  
D O Polovneva ◽  
E V Porozhnyuk ◽  
R G Shevtsova
1989 ◽  
Vol 25 (8) ◽  
pp. 412-414
Author(s):  
N. V. Barsukova ◽  
Z. I. Niidusaar ◽  
K. E. Zvyagin ◽  
I. N. Myasnikov

Author(s):  

Phenol sorption from model water solutions and waste waters by ionites has been studied in static and dynamic conditions. The sorption process rate constants, activation energy and indices of diffusion have been calculated. The main technological parameters of phenol sorption from waste waters have been determined.


1994 ◽  
Vol 72 (01) ◽  
pp. 140-145 ◽  
Author(s):  
Valeri Kolpakov ◽  
Maria Cristina D'Adamo ◽  
Lorena Salvatore ◽  
Concetta Amore ◽  
Alexander Mironov ◽  
...  

SummaryActivated neutrophils may promote thrombus formation by releasing proteases which may activate platelets, impair the fibrinolytic balance and injure the endothelial monolayer.We have investigated the morphological correlates of damage induced by activated neutrophils on the vascular wall, in particular the vascular injury induced by released cathepsin G in both static and dynamic conditions.Human umbilical vein endothelial cells were studied both in a cell culture system and in a model of perfused umbilical veins. At scanning electron microscopy, progressive alterations of the cell monolayer resulted in cell contraction, disruption of the intercellular contacts, formation of gaps and cell detachment.Contraction was associated with shape change of the endothelial cells, that appeared star-like, while the underlying extracellular matrix, a potentially thrombogenic surface, was exposed. Comparable cellular response was observed in an “in vivo” model of perfused rat arterial segment. Interestingly, cathepsin G was active at lower concentrations in perfused vessels than in culture systems. Restoration of blood flow in the arterial segment previously damaged by cathepsin G caused adhesion and spreading of platelets on the surface of the exposed extracellular matrix. The subsequent deposition of a fibrin network among adherent platelets, could be at least partially ascribed to the inhibition by cathepsin G of the vascular fibrinolytic potential.This study supports the suggestion that the release of cathepsin G by activated neutrophils, f.i. during inflammation, may contribute to thrombus formation by inducing extensive vascular damage.


Author(s):  
Y.N. Rybakov ◽  
◽  
V.E. Danilov ◽  
I.V. Danilov ◽  
◽  
...  

The problem of losses of oil products from leaks during their storage and transportation at oil supply facilities is considered. The influence of oil product leaks on the environmental situation around oil depots and gas stations is shown. A detailed overview of existing methods and tools for detecting leaks of petroleum products from storage facilities is presented. The evaluation of their effectiveness. Two methods for detecting oil leaks and devices based on them are proposed. The first device monitors the movement of liquid in the tank, the second-detects petroleum products in wastewater. The problem of recovery of petroleum vapors and environmental pollution from the release of vapors of light fractions into the atmosphere is also considered. An overview of existing methods and means of recovery of petroleum vapors is presented. Two methods and devices for capturing oil vapors and returning them to the reservoir are proposed, based on different principles: vapor absorption in the cooled oil product and vapor recovery on the principle of the Carnot cycle. It is shown that these devices can provide effective detection of oil leaks and recovery of their vapors, as well as improve the effectiveness of environmental protection at modern gas stations and tank farms.


2020 ◽  
Vol 0 (2) ◽  
pp. 21-25
Author(s):  
Nikolay Dubenok ◽  
Andrey Novikov ◽  
Sergei Borodychev ◽  
Maria Lamskova

At the stage of water treatment for irrigation systems, the efficiency capture coarse and fine mechanical impurities, as well as oil products and organic compounds affects the reliability of the equipment of the irrigation network and the safety of energy exchange processes in irrigated agricultural landscapes. The violation of work irrigation system can cause disruptions in irrigation schedules of agricultural crops, crop shortages, degradation phenomena on the soil and ecological tension. For the combined irrigation system, a water treatment unit has been developed, representing a hydrocyclone apparatus with a pipe filter in the case. For the capacity of 250 m3/h the main geometrical dimensions of hydrocyclone have been calculated. To organize the capture petroleum products and organic compounds, it has been proposed a modernization of a hydrocyclone unit, consisting in dividing the cylindrical part of the apparatus into two section. The first is section is for input irrigation water, the second one is for additional drainage of clarified irrigation water after sorption purification by the filter, placed on the disk and installed coaxially with the drain pipe and the pipe filter.


Sign in / Sign up

Export Citation Format

Share Document