scholarly journals Determination of the real energy efficiency of the inlet ventilation air heater and air curtain

Author(s):  
Anna Mozgova ◽  
Tatyana Shennikova
Author(s):  
Fabian Cano-Ardila ◽  
Juan David Giraldo-Quintero ◽  
Sergio Cipriano Agudelo-Flórez

This work addresses the methodology to determine the exact concentration ratio (CR) for a parabolic solar concentrator (PSC) using thermographic imaging. The value of CR is commonly given in terms of the area of the receiver and not in terms of the area of the image produced by the concentrator on the receiver surface. With thermographic analysis, it is possible to know the real image generated by the PSC on the receiver, which helps to have a precise calculation of CR. It is important to measure the real CR not only for manufacturing purposes but also for the maintenance of solar concentrators, since its miscalculation lowers their energy efficiency or lifespan. In experiments, the real image on the receiver is divided into 4 regions, stratified with an equal temperature difference for each one. With this consideration, CR varied from 20 to 151. To complete the analysis, the energy efficiency is calculated. Since heating is a non-stationary process, thermal efficiency fluctuated during the time of experimentation, having a peak of 25% and a mean value of 15.3%. The irregularities of curvature in the concentrators significantly deteriorate the uniformity of the radiation flux and the energy efficiency due to unused areas of concentration.


2017 ◽  
Vol 107 (05) ◽  
pp. 352-358
Author(s):  
S. Prof. Simon ◽  
S. Wichmann ◽  
A. Brill

Von der Brandenburgischen Technischen Universität (BTU) sind in Zusammenarbeit mit der TU Liberec Untersuchungen zur Verbesserung der Energieeffizienz an spanenden Werkzeugmaschinen durchgeführt worden. Im Gegensatz zu bereits durchgeführten Untersuchungen wurde der Fokus hier auf das Belastungsverhalten im Teillastbereich gerichtet. Die durchgeführten Untersuchungen beschränkten sich auf das Längsdrehen mit geringen Schnitttiefen. Als Werkstoffe kamen ein Baustahl und ein Vergütungsstahl zum Einsatz. Durch die Bestimmung der Leerlaufleistung der verwendeten Drehmaschine waren tatsächliche Aussagen über die Schnittleistung möglich. Für das Ermitteln des Wirkungsgrades wurden auch die Schnittleistungen bei verschiedenen Drehzahlen aufgenommen. Alle weiteren Spanungsbedingungen blieben für die Untersuchungen konstant. Im Ergebnis der Untersuchung bestätigte sich das Potenzial der Minimalmengenschmierung. Der Wirkungsgrad verbesserte sich durchschnittlich um 5 %. Beachtenswert ist der Einfluss des Einstellwinkels. Hier liegt das Optimierungspotenzial der Energieeffizienz in Summe bei 14 %. Die Untersuchungen ergaben weiterhin eine hohe Korrelation von Spanungsbedingungen, Werkstückwerkstoff und verwendetem Schmiermittel.   The Brandenburg University of Technology has carried out investigations in cooperation with the technical University of Liberec to improve the energy efficiency of cutting machine tools. In contrast to investigations already carried out, the focus here was on the loading behavior in the partial load range. The investigations carried out were limited to longitudinal turning with low cutting depths. A structural steel and a tempering steel were used as materials. By determining the no-load power of the used lathe, actual statements about the cutting performance were possible. For the determination of the efficiency, the cutting performance was recorded at different speeds. All further stress conditions remained constant for the investigations. As a result of the investigation, the potential of minimum quantity lubrication was confirmed. The efficiency improved by an average of 5 %. The influence of the angle of setting was remarkable. The optimization potential of energy efficiency was at 14 %. The investigations also revealed a high correlation between stress conditions, workpiece material and lubricant used.


2015 ◽  
Vol 19 (6) ◽  
pp. 2233-2244
Author(s):  
Slobodan Misanovic ◽  
Zlatomir Zivanovic ◽  
Slaven Tica

Research in this paper comprised experimental determination of energy efficiency of different bus subsystems (diesel bus, trolleybus and fully electric bus) on chosen public transport route in Belgrade. Experimental measuring of energy efficiency of each bus type has been done based on the analysis of parameters of vehicle driving cycles between stops. Results of this analysis were basis for development of theoretical simulation model of energy efficiency. The model was latter compared with the results of simulation done by "Solaris bus & Coach" company for the chosen electric bus route. Based on demonstrated simulation, characteristics of electric bus batteries were defined, the method and dynamic of their recharge was suggested, as well as choice for other aggregates for drive system and technical characteristics for the electric buses were suggested.


2020 ◽  
Vol 42 (2) ◽  
pp. 68-75
Author(s):  
V.G. Demchenko ◽  
А.S. Тrubachev ◽  
A.V. Konyk

Worked out methodology of determination of the tensely-deformed state of elements of mobile heat storage of capacity type, that works in the real terms of temperature and power stress on allows to estimate influence of potential energy on resilient deformation that influences on reliability of construction and to give recommendations on planning of tank (capacities) of accumulator. For determination possibly of possible tension of construction of accumulator kinematics maximum terms were certain. As a tank of accumulator shows a soba the difficult geometrical system, the mathematical model of calculation of coefficient of polynomial and decision of task of minimization of functional was improved for determination of tension for Міzеs taking into account the real geometry of equipment. Conducted quantitative estimation of the tensely-deformed state of the union coupling, corps and bottom of thermal accumulator and the resource of work of these constructions is appraised. Thus admissible tension folds 225 МРа.


Author(s):  
Kamil Krasuski ◽  
Stepan Savchuk

This paper presents results of research concerning determination of the GPS reference station coordinates located on the grounds of an EPDE airport in Deblin. The study uses a mathematical model of the PPP measurement technique in order to determine the coordinates of the reference station using the real GPS code-phase observations. The computations of the coordinates of the GPS reference station were carried out in numerical applications CSRS-PPP, APPS and GAPS. In this research was found that the accuracy of finding solutions to the XYZ geocentric coordinates of the reference station REF1 between solutions CSRS-PPP, APPS and GAPS ranges from 0.01m to 0.13m. In addition, the accuracy of determining the XYZ geocentric coordinates from the PPP method related to the GPS differential solution ranged from 0.01m to 0.11m.


1969 ◽  
Vol 17 (1) ◽  
pp. 71-79
Author(s):  
A.I. Golovanov

Experiments were made to determine the influence of size of soil sample, convection and water flow on the determination of thermal conductivity of soils using a thin needle (0.05 cm radius, 8.5 cm in length) as the heating element and copper cylinders for sample containers. For measurements during a period of 100 seconds the diameter of the sample must be at least 4 cm and to avoid any influence of convection measurements should not exceed 100 seconds. When heating elements are placed horizontally to measure simultaneously the thermal conductivity of different soil layers they should be placed at least 10 cm apart. Thermal conductivity measurements could be used to determine flow velocities of water in coarse sand samples provided that the real flow velocity was highev than 0.35 cm/ min. (Abstract retrieved from CAB Abstracts by CABI’s permission)


2021 ◽  
Vol 236 ◽  
pp. 02033
Author(s):  
Xiaoyan Ge ◽  
Qian Mo ◽  
Guofeng Wang ◽  
Yan Zhao ◽  
Yongyu Li ◽  
...  

Antimony (Sb) is a toxic and potentially carcinogenic metalloid element. The toxicity of Sb in the environment strongly relies on its speciation. It is necessary to investigate the speciation and content of antimony in soil in order to understand better the real risk associated with Sb in the environment. This study developed water bath heating and soaking-AFS methods to determine the available and carbonate antimony in soil. Through analysis and mutual verification experiments in three different laboratories, the repeatability and reproducibility in the precision experiment were less than 3.44, the average recovery rate was more than 98.1%. These methods were accurate, reproducible and effective for detecting the content of available and carbonate antimony in soil.


Sign in / Sign up

Export Citation Format

Share Document