Paper-based Triboelectric Nanogenerator and Activities of Salt Ions

Author(s):  
Shatrudhan Palsaniya ◽  
Komal Nehra ◽  
Ashok Kumar Dasmahapatra

Abstract This work presents a triboelectric nanogenerator (TENG) fabrication using polytetrafluoroethylene, aluminum foil, and cellulose paper. Mechanical interactions lead to atomic defects that stimuli the delocalized electrostatic charge carriers and kinetic energy. The addition of ionic salt’s microdroplets improved the TENG’s performance. Eventually, surface charge activities have escalated the electrical signals. Further, studied spontaneously increased charge transport performance at the steady-state condition in the presence of NaCl ionic droplets. We considered that these ionic activities actively participated in detecting salt ions.

Computation ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 65
Author(s):  
Aditya Dewanto Hartono ◽  
Kyuro Sasaki ◽  
Yuichi Sugai ◽  
Ronald Nguele

The present work highlights the capacity of disparate lattice Boltzmann strategies in simulating natural convection and heat transfer phenomena during the unsteady period of the flow. Within the framework of Bhatnagar-Gross-Krook collision operator, diverse lattice Boltzmann schemes emerged from two different embodiments of discrete Boltzmann expression and three distinct forcing models. Subsequently, computational performance of disparate lattice Boltzmann strategies was tested upon two different thermo-hydrodynamics configurations, namely the natural convection in a differentially-heated cavity and the Rayleigh-Bènard convection. For the purposes of exhibition and validation, the steady-state conditions of both physical systems were compared with the established numerical results from the classical computational techniques. Excellent agreements were observed for both thermo-hydrodynamics cases. Numerical results of both physical systems demonstrate the existence of considerable discrepancy in the computational characteristics of different lattice Boltzmann strategies during the unsteady period of the simulation. The corresponding disparity diminished gradually as the simulation proceeded towards a steady-state condition, where the computational profiles became almost equivalent. Variation in the discrete lattice Boltzmann expressions was identified as the primary factor that engenders the prevailed heterogeneity in the computational behaviour. Meanwhile, the contribution of distinct forcing models to the emergence of such diversity was found to be inconsequential. The findings of the present study contribute to the ventures to alleviate contemporary issues regarding proper selection of lattice Boltzmann schemes in modelling fluid flow and heat transfer phenomena.


Nanoscale ◽  
2017 ◽  
Vol 9 (27) ◽  
pp. 9668-9675 ◽  
Author(s):  
Jia Jia Shao ◽  
Wei Tang ◽  
Tao Jiang ◽  
Xiang Yu Chen ◽  
Liang Xu ◽  
...  

A multi-dielectric-layered vertical contact-separation mode TENG through a corona discharge approach results in outstanding output performances, i.e., a high surface charge density of 283 μC m−2 and excellent cycling stability (92.6% retention after 200 000 cycles).


1974 ◽  
Vol 36 (1) ◽  
pp. 59-66
Author(s):  
Oscar A. Gómez-Poviña ◽  
Carmen Sainz de Calatroni ◽  
Susana Orden de Puhl ◽  
Mariano J. Guerrero

2006 ◽  
Author(s):  
Zhilin Qi ◽  
Zhimin Du ◽  
Baosheng Liang ◽  
Yong Tang ◽  
Shouping Wang ◽  
...  

2010 ◽  
Vol 62 (12) ◽  
pp. 2801-2810 ◽  
Author(s):  
Yen-Hui Lin

A pilot-scale fixed-biofilm reactor (FBR) was established to treat textile wastewater to evaluate the feasibility of replacing conventional treatment processes that involve activated sludge and coagulation units. A kinetic model was developed to describe the biodegradation of textile wastewater by FBR. Batch kinetic tests were performed to evaluate the biokinetic parameters that are used in the model. FBR column test was fed with a mean COD of 692 mg/L of textile wastewater from flow equalization unit. The influent flow rate was maintained at 48.4 L/h for FBR column test. Experimental data and model-predicted data for substrate effluent concentration (as COD), concentration of suspended biomass in effluent and the amount of carbon dioxide (CO2) produced in the effluent agree closely with each other. Microscopic observations demonstrated that the biofilm exhibited a uniform distribution on the surface of polyurethane foam sponge. Under a steady-state condition, the effluent COD from FBR was about 14.7 mg COD/L (0.0213 Sb0), meeting the discharge standard (COD < 100 mg/L) that has been set by the government of Taiwan for textile wastewater effluent. The amount of biofilm and suspended biomass reached a maximal value in the steady state when the substrate flux reached a constant value and remained maximal. Approximately 33% of the substrate concentration (as COD) was converted to CO2 during biodegradation in the FBR test. The experimental and modeling schemes proposed in this study could be employed to design a full-scale FBR to treat textile wastewater.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4732
Author(s):  
Jing Yang ◽  
Yue Lv ◽  
Dianhai Liu ◽  
Zhengwei Wang

Pumped-storage power stations play a regulatory role in the power grid through frequent transition processes. The pressure pulsation in the draft tube of the pump-turbine under transient processes is important for safe operation, which is more intense than that in the steady-state condition. However, there is no effective method to obtain the exact pressure in the draft tube in the transient flow field. In this paper, the pressure in the draft tube of a pump-turbine under steady-state and transient conditions are studied by means of CFD. The reliability of the simulation method is verified by comparing the real pressure pulsation data with the test results. Due to the distribution of the pressure pulsation in the draft tube being complex and uneven, the location of the pressure monitoring points directly affects the accurate judgement of cavitation. Eight monitoring surfaces were set in the straight cone of the draft tube and nine monitoring points were set on each monitoring surface to analyze the pressure differences on the wall and inside the center of the draft tube. The relationships between the pressure pulsation value inside the center of the draft tube and on the wall are studied. The “critical” wall pressure pulsation value when cavitation occurs is obtained. This study provides references for judging cavitation occurrences by using the wall pressure pulsation value in practical engineering.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Masoud Behzad ◽  
Benjamin Herrmann ◽  
Williams R. Calderón-Muñoz ◽  
José M. Cardemil ◽  
Rodrigo Barraza

Purpose Volumetric air receivers experience high thermal stress as a consequence of the intense radiation flux they are exposed to when used for heat and/or power generation. This study aims to propose a proper design that is required for the absorber and its holder to ensure efficient heat transfer between the fluid and solid phases and to avoid system failure due to thermal stress. Design/methodology/approach The design and modeling processes are applied to both the absorber and its holder. A multi-channel explicit geometry design and a discrete model is applied to the absorber to investigate the conjugate heat transfer and thermo-mechanical stress levels present in the steady-state condition. The discrete model is used to calibrate the initial state of the continuum model that is then used to investigate the transient operating states representing cloud-passing events. Findings The steady-state results constitute promising findings for operating the system at the desired airflow temperature of 700°C. In addition, we identified regions with high temperatures and high-stress values. Furthermore, the transient state model is capable of capturing the heat transfer and fluid dynamics phenomena, allowing the boundaries to be checked under normal operating conditions. Originality/value Thermal stress analysis of the absorber and the steady/transient-state thermal analysis of the absorber/holder were conducted. Steady-state heat transfer in the explicit model was used to calibrate the initial steady-state of the continuum model.


Sign in / Sign up

Export Citation Format

Share Document