scholarly journals Case series of late lead dislodgement of Medtronic SelectSecure 3830 pacing leads in growing paediatric patients

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Li Yen Ng ◽  
Sarah Gallagher ◽  
Kevin P Walsh

AbstractBackground The SelectSecure lumenless 3830 pacing lead is often considered to be the pacing lead of choice for transvenous pacing in children because of its small diameter, lead strength, and reliable long-term sensing and pacing characteristics. One of the potential long-term pitfalls of a sturdy pacing lead is relative retraction with growth in children resulting in late lead dislodgement.Case summary We report two cases of late SelectSecure 3830 lead dislodgement at 11.8 years (Case 1) and 8.8 years (Case 2), respectively, post the initial implantation. Case 1 was diagnosed with congenital complete heart block (CHB) at 9 months old when he presented with unconfirmed diphtheria infection. Case 2 was diagnosed with CHB at 14 weeks of age with positive maternal anti-Ro antibodies. Both patients underwent implantation of a transvenous permanent pacemaker implantation with Medtronic SelectSecure 3830 lead due to symptomatic bradycardia. Apart from a pulse generator change at 8.5 years (Case 1) and 7 years (Case 2), respectively, post-implant due to normal battery depletion, both patients are well in the interim.Discussion As part of the pacemaker follow-up for rapidly growing children, we recommend more frequent surveillance of lead ‘tautness’ by chest radiography especially in children with CHB with no underlying heart rhythm.

2020 ◽  
Vol 4 (3) ◽  
pp. 1-6
Author(s):  
Ewa Jędrzejczyk-Patej ◽  
Aleksandra Woźniak ◽  
Linda Litwin ◽  
Alina Skiba-Zdrzałek ◽  
Michał Mazurek ◽  
...  

Abstract Background A leadless pacemaker is a new concept in which a miniaturized pacing device is self-contained within the heart. Recently published data show that leadless pacemakers are associated with a decreased risk of major complications when compared with transvenous cardiac pacemakers. This seems to be of particular importance in children and young adults in whom various complications may occur during their lifetime. Case summary Herein, we report the successful implantation of Micra™ Transcatheter Pacing System in two children: 12-year-old boy and 13-year-old girl, along with a long-term follow-up. The children had indications for pacemaker implantation, however, with an expected low percentage of pacing due to paroxysmal nature of the third-degree atrioventricular block. The implantation procedures were performed in general anaesthesia. There were no complications. During the 2-year follow-up, there were no adverse events and the electrical parameters of the device remained stable. Pacing percentage was below 0.1%. Discussion Transvenous cardiac pacemakers improve quality of life and reduce mortality but may be associated with various short- and long-term complications, mainly related to the presence of transvenous leads and the pulse generator. Compared with adult patients, the implantation of conventional pacemakers in children is still a challenge, not only because of their smaller size but also due to continuing growth, as well as a higher rate of lead and device-related complications. We demonstrate that the implantation of leadless pacemakers in children is feasible and could be worth considering in certain clinical scenarios, especially when ventricular pacing is required rarely.


Author(s):  
Minati Choudhury ◽  
Jitin Narula ◽  
Milind P. Hote ◽  
Sarita Mohapatra

AbstractPermanent pacemaker implantation in low birthweight (LBW) babies with congenital complete heart block is extremely challenging due to a paucity of appropriate pulse generator placement pocket sites. The development of infection following an implantation procedure can pose a life-threatening risk to the patients. With more patients in the younger group receiving these devices than ever before and the rate of infection increasing rapidly, a closer look at the burden of infection and its impact on outcome of these patients is warranted. We report mucormycosis infection at the abdominal pacemaker pocket site of an infant requiring pacemaker explantation and re-insertion into the intrapleural space.


2019 ◽  
Vol 8 (1) ◽  
pp. 35 ◽  
Author(s):  
Mª Reyes Carrión-Camacho ◽  
Ignacio Marín-León ◽  
José Manuel Molina-Doñoro ◽  
José Rafael González-López

Although pacemaker implantation is considered to be low risk, it is not exempt from complications and technical failures during the procedure, both in the short and long term, and the complications that such patients may present remain unknown. The aim has been to analyze the complication rates associated with permanent pacing and to identify if these differ between patients with or without previous antithrombotic therapy. We used a prospective, single center, observational study of 310 adult patients with indications of permanent pacing. They were hospitalized from 1 January to 31 December 2014 and followed up for 6 months after the pacemaker implant. The participants were distributed into two groups according to the antithrombotic therapy prior to the implant. The most frequent major complications were pneumothorax (3.87%) and lead dislodgement (8.39%), while superficial phlebitis (12.90%) and uncomplicated hematomas (22.58%) were presented as the most recurrent minor complications. Hematomas were the most frequent minor complication in the antithrombotic therapy cohort, and shoulder pain was reported as the most recurrent minor complication in the non-exposed group. Finding out about complications in pacemaker implants enables a complete view of the process, and hence the prioritization of actions aimed at improving safety and reducing associated risks.


2014 ◽  
Vol 71 (11) ◽  
pp. 1049-1054
Author(s):  
Aleksandra Grdinic ◽  
Zoran Stajic ◽  
Aleksandar Grdinic ◽  
Zarko Vucinic ◽  
Violeta Randjelovic-Krstic ◽  
...  

Background/Aim. A possible cause of malignant heart rhythm disorders is the syndrome of sleep apnea (periodic cessation of breathing during sleep longer than 10 seconds). Recent 24h ECG software systems have the option of determination ECG apnea index (AI) based on the change in voltage of QRS complexes. The aim of the study was to determine the significance of AI evaluation in routine 24-hour Holter ECG on a group of 12 patients. Methods. We presented a total of 12 consecutive patients with previously documented arrhythmias and the history of breathing disorders during night. They were analyzed by 24 h ECG (Medilog AR 12 plus Darwin), that is able to determine AI. Results. We presented a case series of 12 patients, 8 men and 4 women, mean age 58.75 years and the average AI 5.78. In the whole group there was a trend of increasing prevalence of complex rhythm disorders with increasing of AI and increased frequency of arrhythmias in the night phase vs day phase. Conclusion. Determination of AI using routine long term (24 h) ECG analysis is important because sleep apnea can be successfully treated as an etiological or contributing factor of arrhythmias.


1998 ◽  
Vol 11 (02) ◽  
pp. 85-93 ◽  
Author(s):  
Joanne R. Cockshutt ◽  
H. Dobson ◽  
C. W. Miller ◽  
D. L. Holmberg ◽  
Connie L. Taves ◽  
...  

SummaryA retrospective case series study was done to determine the long-term outcome of operations upon dogs treated for canine hip dysplasia by means of a triple pelvic osteotomy (TPO). Twentyfour dogs with bilateral hip dysplasia, that received a unilateral TPO between January 1988 and June 1995, were re-examined at the Ontario Veterinary College. The assessment included physical, orthopedic and lameness examinations, standard blood work, pelvic radiographs and force plate gait analysis. They were compared to bilaterally dysplastic dogs that had not been treated, and also to normal dogs. Force plate data analysis demonstrated a significant increase in peak vertical force (PVF) and mean vertical force over stance (MVF) in the limb that underwent surgical correction by means of a TPO, when compared to the unoperated hip. It was determined that performing a unilateral TPO on a young dysplastic dog resulted in greater forces and weight bearing being projected through the TPO corrected limb when compared to the unoperated limb.Dogs with bilateral hip dysplasia treated with a unilateral triple pelvic osteotomy (TPO) were assessed by force plate gait analysis, radiographs and orthopedic examination. There was a significant increase in hip Norberg angles over time, although degenerative changes did progress. Limbs that had been operated upon had significantly greater peak and mean ground reaction forces than limbs that had not received an operation.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 951-958
Author(s):  
Tianhao Liu ◽  
Yu Jin ◽  
Cuixiang Pei ◽  
Jie Han ◽  
Zhenmao Chen

Small-diameter tubes that are widely used in petroleum industries and power plants experience corrosion during long-term services. In this paper, a compact inserted guided-wave EMAT with a pulsed electromagnet is proposed for small-diameter tube inspection. The proposed transducer is noncontact, compact with high signal-to-noise ratio and unattractive to ferromagnetic tubes. The proposed EMAT is designed with coils-only configuration, which consists of a pulsed electromagnet and a meander pulser/receiver coil. Both the numerical simulation and experimental results validate its feasibility on generating and receiving L(0,2) mode guided wave. The parameters for driving the proposed EMAT are optimized by performance testing. Finally, feasibility on quantification evaluation for corrosion defects was verified by experiments.


2020 ◽  
Vol 33 (6) ◽  
pp. 727-733
Author(s):  
Jasmine A. T. DiCesare ◽  
Alexander M. Tucker ◽  
Irene Say ◽  
Kunal Patel ◽  
Todd H. Lanman ◽  
...  

Cervical spondylosis is one of the most commonly treated conditions in neurosurgery. Increasingly, cervical disc replacement (CDR) has become an alternative to traditional arthrodesis, particularly when treating younger patients. Thus, surgeons continue to gain a greater understanding of short- and long-term complications of arthroplasty. Here, the authors present a series of 4 patients initially treated with Mobi-C artificial disc implants who developed postoperative neck pain. Dynamic imaging revealed segmental kyphosis at the level of the implant. All implants were locked in the flexion position, and all patients required reoperation. This is the first reported case series of symptomatic segmental kyphosis after CDR.


2019 ◽  
Vol 24 (5) ◽  
pp. 549-557
Author(s):  
Malia McAvoy ◽  
Heather J. McCrea ◽  
Vamsidhar Chavakula ◽  
Hoon Choi ◽  
Wenya Linda Bi ◽  
...  

OBJECTIVEFew studies describe long-term functional outcomes of pediatric patients who have undergone lumbar microdiscectomy (LMD) because of the rarity of pediatric disc herniation and the short follow-up periods. The authors analyzed risk factors, clinical presentation, complications, and functional outcomes of a single-institution series of LMD patients over a 19-year period.METHODSA retrospective case series was conducted of pediatric LMD patients at a large pediatric academic hospital from 1998 to 2017. The authors examined premorbid risk factors, clinical presentation, physical examination findings, type and duration of conservative management, indications for surgical intervention, complications, and postoperative outcomes.RESULTSOver the 19-year study period, 199 patients underwent LMD at the authors’ institution. The mean age at presentation was 16.0 years (range 12–18 years), and 55.8% were female. Of these patients, 70.9% participated in competitive sports, and among those who did not play sports, 65.0% had a body mass index greater than 25 kg/m2. Prior to surgery, conservative management had failed in 98.0% of the patients. Only 3 patients (1.5%) presented with cauda equina syndrome requiring emergent microdiscectomy. Complications included 4 cases of postoperative CSF leak (2.0%), 1 case of a noted intraoperative CSF leak, and 3 cases of wound infection (1.5%). At the first postoperative follow-up appointment, minimal or no pain was reported by 93.3% of patients. The mean time to return to sports was 9.8 weeks. During a mean follow-up duration of 8.2 years, 72.9% of patients did not present again after routine postoperative appointments. The total risk of reoperation was a rate of 7.5% (3.5% of patients underwent reoperation for the same level; 4.5% underwent adjacent-level decompression, and one patient [0.5%] ultimately underwent a fusion).CONCLUSIONSMicrodiscectomy is a safe and effective treatment for long-term relief of pain and return to daily activities among pediatric patients with symptomatic lumbar disc disease in whom conservative management has failed.


2019 ◽  
Vol 24 (5) ◽  
pp. 558-571 ◽  
Author(s):  
Kartik Bhatia ◽  
Hans Kortman ◽  
Christopher Blair ◽  
Geoffrey Parker ◽  
David Brunacci ◽  
...  

OBJECTIVEThe role of mechanical thrombectomy in pediatric acute ischemic stroke is uncertain, despite extensive evidence of benefit in adults. The existing literature consists of several recent small single-arm cohort studies, as well as multiple prior small case series and case reports. Published reports of pediatric cases have increased markedly since 2015, after the publication of the positive trials in adults. The recent AHA/ASA Scientific Statement on this issue was informed predominantly by pre-2015 case reports and identified several knowledge gaps, including how young a child may undergo thrombectomy. A repeat systematic review and meta-analysis is warranted to help guide therapeutic decisions and address gaps in knowledge.METHODSUsing PRISMA-IPD guidelines, the authors performed a systematic review of the literature from 1999 to April 2019 and individual patient data meta-analysis, with 2 independent reviewers. An additional series of 3 cases in adolescent males from one of the authors’ centers was also included. The primary outcomes were the rate of good long-term (mRS score 0–2 at final follow-up) and short-term (reduction in NIHSS score by ≥ 8 points or NIHSS score 0–1 at up to 24 hours post-thrombectomy) neurological outcomes following mechanical thrombectomy for acute ischemic stroke in patients < 18 years of age. The secondary outcome was the rate of successful angiographic recanalization (mTICI score 2b/3).RESULTSThe authors’ review yielded 113 cases of mechanical thrombectomy in 110 pediatric patients. Although complete follow-up data are not available for all patients, 87 of 96 (90.6%) had good long-term neurological outcomes (mRS score 0–2), 55 of 79 (69.6%) had good short-term neurological outcomes, and 86 of 98 (87.8%) had successful angiographic recanalization (mTICI score 2b/3). Death occurred in 2 patients and symptomatic intracranial hemorrhage in 1 patient. Sixteen published thrombectomy cases were identified in children < 5 years of age.CONCLUSIONSMechanical thrombectomy may be considered for acute ischemic stroke due to large vessel occlusion (ICA terminus, M1, basilar artery) in patients aged 1–18 years (Level C evidence; Class IIb recommendation). The existing evidence base is likely affected by selection and publication bias. A prospective multinational registry is recommended as the next investigative step.


Sign in / Sign up

Export Citation Format

Share Document