scholarly journals 411 Reproducibility and applicability of automated speckle tracking echocardiography in patients with aortic valve stenosis

2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Caterina Butturini ◽  
Diego Fanti ◽  
Paolo Springhetti ◽  
Enrico Tadiello ◽  
Corinna Bergamini ◽  
...  

Abstract Aims New speckle tracking echocardiography (STE) tools allow an automated detection of strain measurements, but in case of suboptimal image quality or electrocardiogram signal, both regions-of-interest (ROIs) tracking and cardiac cycle’s landmarks need to be edited. In this study, we aimed to assess the variability of STE measurement performed with Tomtec’s Autostrain LV/RV/LA® application across different operators’ expertise in patients with significant aortic valve stenosis, known to have often suboptimal acoustic windows. Methods and results Automated strain analysis was performed by two observers with different levels of expertise in STE (a student sonographer and a trained cardiologist) on scans from 30 consecutive patients with moderate to severe aortic stenosis. Interobserver variability was tested. Intra-observer variability was also assessed repeating measurements about one month after the first set. Manual editing of the automated ROIs or cardiac cycle landmarks tracing results was manually made from both users on the majority (>80%) of examinations; notably RV strain analysis required the least editing. At repeated measurement test (Figure), the average strain values were not found to be significantly different for measurements of apical-four-chamber-global-longitudinal-strain (A4C-GLS) (mean difference 0.96%, P = 0.08), left-atrium-longitudinal strain (LALS) (peak-atrial-longitudinal-strain, PALS, mean difference −0.89% P = 0.37; peak-atrial-contraction-strain, PACS, mean difference −0.76%, P = 0.13) and right-ventricle-free-wall-strain (RV-FWS) (mean difference 0.44%, P = 0.59). A stronger agreement between testers was observed for patients with markedly reduced left-ventricle-global-longitudinal-strain (LV-GLS) and was not affected by the quality of acoustic windows. Similar trend was evident for the left atrial and right ventricular parameters. Conclusions New tool AutoStrain LV/RV/LA® for automated strain analysis showed a good agreement between operators with different levels of expertise in the challenging setting of patients with aortic valve stenosis. The reproducibility was particularly accurate for A4C view and in patients with worse LV-GLS values, independently from image quality.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Saikrishna Ananthapadmanabhan ◽  
Giau Vo ◽  
Tuan Nguyen ◽  
Hany Dimitri ◽  
James Otton

Abstract Background Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. Methods We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. Results Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). Conclusion There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain


2010 ◽  
Vol 299 (3) ◽  
pp. H664-H672 ◽  
Author(s):  
Noa Bachner-Hinenzon ◽  
Offir Ertracht ◽  
Marina Leitman ◽  
Zvi Vered ◽  
Sara Shimoni ◽  
...  

The rat heart is commonly used as an experimental model of the human heart in both health and disease states, assuming that heart function of rats and humans is alike. When studying a rat model, echocardiography is usually performed on sedated rats, whereas standard echocardiography on adult humans does not require any sedation. Since echocardiography results of sedated rats are usually inferred to alert humans, in the present study, we tested the hypothesis that differences in left ventricular (LV) function may be present between rats sedated by a low dose of ketamine-xylazine and alert humans. Echocardiography was applied to 110 healthy sedated rats and 120 healthy alert humans. Strain parameters were calculated from the scans using a layer-specific speckle tracking echocardiography program. The results showed that layer longitudinal strain is equal in rats and humans, whereas segmental strain is heterogeneous ( P < 0.05) in a different way in rats and humans ( P < 0.05). Furthermore, layer circumferential strain is larger in humans ( P < 0.001), and the segmental results showed different segmental heterogeneity in rats and humans ( P < 0.05). Radial strain was found to be homogeneous at the apex and papillary muscle levels in humans and heterogeneous in rats ( P < 0.001). Additionally, whereas LV twist was equal in rats and humans, in rats the rotation was larger at the apex ( P < 0.01) and smaller at the base ( P < 0.001). The torsion-to-shortening ratio parameter, which indicates the transmural distribution of contractile myofibers, was found to be equal in rats and humans. Thus, when evaluating LV function of sedated rats under ketamine-xylazine, it is recommended to measure the global longitudinal strain, LV twist, and torsion-to-shortening ratio, since no scaling is required when converting these parameters and inferring them to humans.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
MM Kylmala ◽  
S Syvaranta ◽  
R Halva ◽  
R Orn ◽  
H Rajala ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Global longitudinal strain (GLS) by echocardiography is a sensitive method for measuring left ventricular (LV) function, and of better prognostic value in valvular heart disease than ejection fraction (EF). Cardiac magnetic resonance imaging (CMR) is the most accurate method for measuring LV volume and EF, but GLS has not been possible to measure by CMR until recently. Purpose This study compares GLS obtained by CMR and echocardiography in patients with severe aortic valve stenosis. Normal values for GLS by CMR are reported as well. Methods GLS was measured in 32 patients with severe aortic valve stenosis with speckle tracking echocardiography, using GE Vivid E95 (n = 15) and Philips EPIQ (n = 17) ultrasound machines, as well as with CMR (Avanto 1.5T FIT, Siemens Medical Solutions). For normal values, GLS was measured by CMR in 9 healthy controls. Endo- and epicardial borders of two, three and four chamber cine images were traced for CMR GLS using dedicated software (Qstrain 2.0, Medis, NL). Both CMR and Vivid E95 measured midmyocardial strain, whereas the EPIQ AutoStrain method measures endomyocardial strain. Absolute values of GLS are reported. Pearson correlation coefficient was calculated and paired Student’s t-test was used for comparisons. Results A significant correlation (r = 0.45, p = 0.01) was found between echocardiographic and CMR GLS (Figure). GLS by Vivid E95 had a very good correlation with CMR GLS (r = 0.84, p = 0.0001), whereas GLS by Philips EPIQ did not correlate significantly (r = 0.14, p = 0.01). In patients with aortic stenosis and healthy controls, the average GLS by CMR was 18.3 ± 3% and 20.9 ± 2% respectively. The average GLS by CMR was comparable to that obtained by GE Vivid E95 (17.3 ± 4% vs. 17.2 ± 3%, p = 0.92), and higher than by Philips EPIQ (19.2 ± 2% vs. 15.4 ± 2%, p &lt; 0.0001). Conclusion This study shows that GLS by CMR is feasible and correlates with GLS obtained by echocardiography, especially when quantifying midmyocardial strain. Echocardiographic GLS values based on endomyocardial strain were lower. Patient characteristics Age 75 ± 14 y NYHA 1 1 (3 %) NYHA 2 20 (67 %) NYHA 3 8 (27 %) NYHA 4 1 (3 %) CMR EF 66 ± 8 % AVA 0.7 ± 0.2 cm&sup2; NYHA = NYHA class of symptoms, EF = ejection fraction by CMR, AVA = aortic valve area by echocardiography Abstract Figure. GLS by CMR vs. Echocardiography


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 562
Author(s):  
Rima Šileikienė ◽  
Karolina Adamonytė ◽  
Aristida Ziutelienė ◽  
Eglė Ramanauskienė ◽  
Jolanta Justina Vaškelytė

Background and objectives: Childhood obesity has reached epidemic levels in the world. Obesity in children is defined as a body mass index (BMI) equal to or above the 95th percentile for age and sex. The aim of this study was to determine early changes in cardiac structure and function in obese children by comparing them with their nonobese peers, using echocardiography methods. Materials and methods: The study enrolled 35 obese and 37 age-matched nonobese children. Standardized 2-dimensional (2D), pulsed wave tissue Doppler, and 2D speckle tracking echocardiography were performed. The z-score BMI and lipid metabolism were assessed in all children. Results: Obese children (aged 13.51 ± 2.15 years; 20 boys; BMI z-score of 0.88 ± 0.63) were characterized by enlarged ventricular and atrial volumes, a thicker left ventricular posterior wall, and increased left ventricular mass. Decreased LV and RV systolic and diastolic function was found in obese children. Atrial peak negative (contraction) strain (−2.05% ± 2.17% vs. −4.87% ± 2.97%, p < 0.001), LV and RV global longitudinal strain (−13.3% ± 2.88% vs. −16.87% ± 3.39%; −12.51% ± 10.09% vs. −21.51% ± 7.42%, p < 0.001), and LV global circumferential strain (−17.0 ± 2.7% vs. −19.5 ± 2.9%, p < 0.001) were reduced in obese children. LV torsion (17.94° ± 2.07° vs. 12.45° ± 3.94°, p < 0.001) and normalized torsion (2.49 ± 0.4°/cm vs. 1.86 ± 0.61°/cm, p = 0.001) were greater in obese than nonobese children. A significant inverse correlation was found between LV and RV global longitudinal strain and BMI (r = −0.526, p < 0.01; r = −0.434, p < 0.01) and total cholesterol (r = −0.417, p < 0.01). Multivariate analysis revealed that the BMI z-score was independently related to LV and RV global longitudinal strain as well as LV circumferential and radial strain. Conclusion: 2D speckle tracking echocardiography is beneficial in the early detection of regional LV systolic and diastolic dysfunctions, with preserved ejection fraction as well as additional RV and atrial involvement, in obese children. Obesity may negatively influence atrial and ventricular function, as measured by 2D speckle tracking echocardiography. Obese children, though they are apparently healthy, may have subclinical myocardial dysfunction.


2020 ◽  
Vol 30 (3) ◽  
pp. 154
Author(s):  
Paolo Zappulla ◽  
Giuseppe Bottaro ◽  
Wanda Deste ◽  
Francesca Famà ◽  
Federica Agnello ◽  
...  

2020 ◽  
Vol 14 ◽  
pp. 117954682093001
Author(s):  
Manal F Elshamaa ◽  
Fatma A Mostafa ◽  
Inas AES Sad ◽  
Ahmed M Badr ◽  
Yomna AEM Abd Elrahim

Background: Cardiac systolic dysfunction was potentially found in adult patients with end-stage renal disease (ESRD) who have preserved left ventricular ejection fraction (EF%). In children with ESRD, little data are available on early changes in myocardial function. This study aimed to detect the early changes in myocardial mechanics in pediatric patients with ESRD using speckle tracking echocardiography (STE). Methods: Thirty ESRD children receiving hemodialysis (HD) and30 age-matched controls were prospectively studied. Patients underwent echocardiographic studies before and after HD. Left ventricular longitudinal strain (LS), circumferential strain (CS), and radial strain (RS) myocardial deformation parameters (strain, strain rate) were evaluated by STE. Results: The LS was significantly reduced in pre-HD and post-HD patients compared with controls ( P = .000). Controls showed the highest global longitudinal strain. The RS measurements did not differ significantly among the studied groups except for the inferior segment that is significantly reduced after HD compared with controls ( P < .05). The CS was significantly reduced in pre-HD and post-HD patients compared with controls at the lateral and posterior segments ( P = .035 and P = .013, respectively). Conclusion: Speckle-tracking echocardiography might detect early changes in myocardial mechanics in children with ESRD with preserved EF%.


2020 ◽  
Author(s):  
Lori B Croft ◽  
Parasuram Krishnamoorthy ◽  
Richard Ro ◽  
Malcolm Anastasius ◽  
Wenli Zhao ◽  
...  

COVID-19 infection can affect the cardiovascular system. We sought to determine if left ventricular global longitudinal strain (LVGLS) is affected by COVID-19 and if this has prognostic implications. Materials & methods: Retrospective study, with LVGLS was measured in 58 COVID-19 patients. Patients discharged were compared with those who died. Results: The mean LV ejection fraction (LVEF) and LVGLS for the cohort was 52.1 and -12.9 ± 4.0%, respectively. Among 30 patients with preserved LVEF(>50%), LVGLS was -15.7 ± 2.8%, which is lower than the reference mean LVGLS for a normal, healthy population. There was no significant difference in LVGLS or LVEF when comparing patients who survived to discharge or died. Conclusion: LVGLS was reduced in COVID-19 patients, although not significantly lower in those who died compared with survivors.