scholarly journals Radiographic and clinical risk factors of total knee arthroplasty in asymptomatic knees; a 15-year follow-up study

2019 ◽  
Author(s):  
Flemming Kromann Nielsen ◽  
Anne Grethe Jurik ◽  
Anette Jørgensen ◽  
Niels Egund

AbstractBackgroundRadiographic signs of osteoarthritis (OA) are frequent in knees without symptoms. The long-term impact of these findings is not completely elucidated. We wanted to evaluate whether radiographic or clinical baseline findings are associated with the risk of total knee arthroplasty (TKA) in knees without symptomatic OA but with clinical OA of the other knee during a mean follow-up period of 15 years.MethodsA follow-up analysis was performed in 100 persons with unilateral, clinical knee OA according to the ACR (American College of Rheumatology) criteria, who participated in a clinical trial between 2000 and 2002. Baseline radiographs of the contralateral, non-symptomatic knee were available in 88 participants at follow-up. Data on TKA procedures were extracted from the Danish National Patient Register at follow-up. Radiographic and clinical findings were analyzed for associations with subsequent TKA.ResultsAt follow-up, 40% had received a TKA in their non-symptomatic knee. The risk of TKA was significantly associated with baseline joint space narrowing (risk ratio (RR) 1.6 (95% confidence interval (95% CI) 1.4 to 1.9)), osteophytes (RR 1.5 (95% CI 1.3 to 1.8)) and subchondral sclerosis (RR 2.4 (95% CI 1.6 to 3.7)). Among the clinical findings, only baseline body mass index (BMI) was significantly associated with the risk of TKA (RR 1.4 (95& CI 1.1 to 1.8)).ConclusionsRadiographic OA changes and BMI at baseline were significantly associated with the long-term risk of TKA in persons without symptomatic knee OA but with symptomatic OA in the contralateral knee, implying that radiographic OA findings are important prognostic factors regardless of symptoms.

Coatings ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 442 ◽  
Author(s):  
Georg Hauer ◽  
Lukas Leitner ◽  
Marc C. Ackerl ◽  
Sebastian Klim ◽  
Ines Vielgut ◽  
...  

Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.


Author(s):  
Matthew A. Siegel ◽  
Michael J. Patetta ◽  
Angie M. Fuentes ◽  
Armaan S. Haleem ◽  
Craig W. Forsthoefel ◽  
...  

AbstractKnee range of motion (ROM) is an important postoperative measure of total knee arthroplasty (TKA). There is conflicting literature whether patients who are obese have worse absolute ROM outcomes than patients who are not obese. This study analyzed whether preoperative body mass index (BMI) influences knee ROM after patients' primary TKA. A retrospective investigation was performed on patients, who underwent primary TKA at an academic institution, by one of three fellowship-trained adult reconstruction surgeons. Patients were stratified according to their preoperative BMI into nonobese (BMI < 30.0 kg/m2) and obese (BMI ≥ 30.0 kg/m2) classifications. Passive ROM was assessed preoperatively as well as postoperatively at patients' most recent follow-up visit that was greater than 2 years. Mann–Whitney U tests were performed to determine statistical significance at p-value <0.05 for ROM outcomes. No statistically significant differences were observed when ROM in the nonobese group was compared with ROM in the obese group both preoperatively (105.73 ± 11.58 vs. 104.14 ± 13.58 degrees, p-value = 0.417) and postoperatively (105.83 ± 14.19 vs. 104.49 ± 13.52 degrees, p-value = 0.777). Mean follow-up time for all patients was 4.49 ± 1.92 years. In conclusion, long-term postoperative ROM outcomes were similar between patients who were nonobese and patients who were obese.


10.29007/3724 ◽  
2018 ◽  
Author(s):  
Eun-Kyoo Song ◽  
Jong-Keun Seon ◽  
Dong-Hyun Lee ◽  
Je-Hyoung Yeo

Total knee arthroplasty using navigation system is known to be more effective than conventional methods in achieving more accurate bone resection and neutral alignment.1 Mobile bearing is also known to reduce wear and automatically correct rotational malalignment of the tibia but the long-term follow-up results of more than 10 years are extremely rare.2, 3 The purpose of this study is to investigate the results of clinical and radiologic long-term follow-up and complications of total knee arthroplasty using navigation and multi-directional mobile bearing.From 2003 to 2006, a total of 111 navigation TKAs using multi-directional mobile bearing design were carried out and reviewed retrospectively. TKAs were performed by two experienced surgeons at one institute. Of the 111 patients, 102 were women and 9 were men. The mean duration of follow-up was 11.4 ± 1.0 years (range, 10.1 to 14.08 years). Clinical outcomes were evaluated in terms of Knee Society Score, Hospital for Special Surgery score, Western Ontario and McMaster University (WOMAC) score, range of motion and complications. Long-term radiological outcomes and survival rates were evaluated at least 10 years.Average preoperative HSS score was 66.5 ± 9.8 and KSS pain and function score were 25.0 ± 11.8 and 44.5 ± 12.3, respectively. Scores improved to 94.1 ± 8.2, 46.6 ± 11.6 and 88.2 ± 14.6 at the last follow up, respectively. Mean preoperative WOMAC scores of 75.8 ± 16.5 improved to 13.8 ± 16.0 at last follow-up. Five knees required re-operation, two for liner breakage, one for liner wear, one for distal femoral fracture and one for infection. The estimated 10-year prosthesis survival rates for any reason and for prosthesis-related problems were 95.5% and 97.4% , respectively.TKAs using each techniques resulted in similar good clinical outcomes and postoperative leg alignments. Robotic and navigation TKA appeared to reduce the number of postoperative leg alignment outliers and revision rate compared to conventional TKA.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Cheng Chen ◽  
Yanyan Shi ◽  
Zhanpo Wu ◽  
Zengxin Gao ◽  
Youmin Chen ◽  
...  

Abstract Background To determine the long-term effects (a minimum follow-up time 8.8 years) of cemented and cementless fixations used for total knee arthroplasty (TKA). Methods PubMed, EMBASE, Ovid, Cochrane Library, CINAHL, China National Knowledge Infrastructure and China Wangfang database were interrogated for appropriate randomized controlled trials (RCTs) through July 2020. Data were extracted and assessed for accuracy by 2 of the authors acting independently. Any controversial discrepancies were resolved after discussion with a third author. Result Eight RCTs were included with low to moderate bias risks. The cemented fixation of TKA was comparable to cementless fixation in terms of implant survival (relative risk, 1.016; 95% CI 0.978 to 1.056; P = 0.417), Knee Society (KS) knee score (standardized mean difference (SMD), − 0.107; 95% CI − 0.259 to 0.045; P = 0.168), KS function score (SMD − 0.065; 95% CI − 0.238 to 0.109; P = 0.463), KS pain score (SMD − 0.300; 95% CI − 0.641 to 0.042; P = 0.085), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score (SMD − 0.117; 95% CI − 0.307 to 0.073; P = 0.227), HSS score (SMD − 0.027; 95% CI − 0.270 to 0.217; P = 0.829), range of motion (SMD 0.061; 95% CI − 0.205 to 0.327; P = 0.652) at ≥ 8.8 years of follow-up. In terms of radiographic outcomes at ≥ 8.8 years of follow-up, the incidence of a radiolucent line in the cementless group was lower than for the cemented group (SMD 3.828; 95% CI 2.228 to 6.576; P < 0.001). However, the maximum total point motion (MTPM) of the cementless group was greater than for the cemented group (SMD − 0.739; 95% CI − 1.474 to − 0.005; P = 0.048). Conclusions Long-term follow-up verified that cementless and cemented fixation have similar prosthesis survival rates, clinical scores and mobility. However, radiography suggested that each technique had an advantage with regard to the radiolucent line and MTPM.


Author(s):  
David A. Crawford ◽  
Joanne B. Adams ◽  
Michael J. Morris ◽  
Keith R. Berend ◽  
Adolph V. Lombardi

AbstractThe literature is mixed on the long-term fate of knees that undergo manipulation under anesthesia (MUA). The purpose of this study is to evaluate the long-term outcomes and survivorship of patients who required a MUA after primary total knee arthroplasty (TKA) compared with a cohort of patients who did not undergo a MUA. Between 2003 and 2007, 2,193 patients (2,783 knees) underwent primary TKA with 2-year minimum follow-up; 182 knees (6.5%) had a MUA. Patients who had a manipulation were younger (p < 0.001) and had worse preoperative range of motion (ROM) (p < 0.001). Postoperative ROM, Knee Society clinical (KSC), functional, and pain (KSP) scores, revisions, and survivorship were compared between MUA and no MUA. Mean follow-up was 9.7 years. MUA patients had lower postoperative ROM (p < 0.001), change in ROM (p < 0.001), KSC (p < 0.001), KSP (p < 0.001), and change in KSP scores (0.013). Revisions occurred in 18 knees (9.9%) in the MUA group compared with 77 knees (3%) without a MUA (p < 0.001). Most common reason for revision after MUA was continued stiffness (50%). Relative risk for revision after one MUA was 2.01 (95% confidence interval [CI], 1.1–3.8, p < 0.001) and after three or more MUAs were 27.02 (95% CI, 16.5–44.1, p < 0.001). Ten-year survival after MUA was 89.4% (95% CI, 87.1–91.7%) compared with 97.2% (95% CI, 96.9–97.5%) without a MUA (p < 0.001). Patients who undergo a MUA after primary TKA may have a knee at risk with higher revision rates, worse long-term clinical scores, ROM and survivorship.


2012 ◽  
Vol 6 (1) ◽  
pp. 172-178 ◽  
Author(s):  
Philipp Bergschmidt ◽  
Rainer Bader ◽  
Dirk Ganzer ◽  
Christian Hauzeur ◽  
Christoph Lohmann ◽  
...  

Background:Total knee arthroplasty can be considered as a reliable surgical procedure with a good long-term clinical result. However, implant failure due to particle induced aseptic loosening as well as the aspect of hypersensitivity to metal ions still remains an emerging issue.Methods:The purpose of this prospective international multi-centre study was to evaluate the clinical and radiological outcomes and the reliability of the unconstrained Multigen Plus Total Knee System with a new BIOLOX® delta ceramic femoral component. Cemented total knee arthroplasty was performed on 108 patients (110 knees) at seven hospitals in three countries. Clinical and radiological evaluations were performed preoperatively, and after 3, 12 and 24 months postoperatively using the HSS-, WOMAC-, SF-36-score and standardised X-rays.Results:The mean preoperative HSS-Score amounted to 55.5 ± 11.5 points and improved significantly in all postoperative evaluations (85.7 ± 11.7 points at 24 months). Furthermore, improvements in WOMAC- and SF-36-score were evaluated as significant at all points of evaluation. Radiolucent lines around the femoral ceramic component at 24 months were found in four cases. Progression of radiolucent lines was not seen and no implant loosening was observed. During the 24 month follow-up eight patients underwent subsequent surgery due to reasons unrelated to the implant material.Conclusions:The observed clinical and radiological results are encouraging for a long-term survival of the ceramic femoral component. Therefore, ceramic implants could be a promising solution not only for patients with allergies against metallic implant materials, but also for the osteoarthritic knee joint. Long-term follow-up is necessary to draw conclusions regarding the superiority of the ceramic knee implants concerningin vivowear and long-term survivorship.


Sign in / Sign up

Export Citation Format

Share Document