scholarly journals Glass Dynamics and Domain Size in a Solvent-Polymer Weak Gel Measured by Multidimensional Magnetic Resonance Relaxometry and Diffusometry

2019 ◽  
Vol 122 (6) ◽  
Author(s):  
Nathan H. Williamson ◽  
April M. Dower ◽  
Sarah L. Codd ◽  
Amber L. Broadbent ◽  
Dieter Gross ◽  
...  
Author(s):  
Y. H. Liu

Ordered Ni3Fe crystals possess a LI2 type superlattice similar to the Cu3Au structure. The difference in slip behavior of the superlattice as compared with that of a disordered phase has been well established. Cottrell first postulated that the increase in resistance for slip in the superlattice structure is attributed to the presence of antiphase domain boundaries. Following Cottrell's domain hardening mechanism, numerous workers have proposed other refined models also involving the presence of domain boundaries. Using the anomalous X-ray diffraction technique, Davies and Stoloff have shown that the hardness of the Ni3Fe superlattice varies with the domain size. So far, no direct observation of antiphase domain boundaries in Ni3Fe has been reported. Because the atomic scattering factors of the elements in NijFe are so close, the superlattice reflections are not easily detected. Furthermore, the domain configurations in NioFe are thought to be independent of the crystallographic orientations.


Author(s):  
M.J. Hennessy ◽  
E. Kwok

Much progress in nuclear magnetic resonance microscope has been made in the last few years as a result of improved instrumentation and techniques being made available through basic research in magnetic resonance imaging (MRI) technologies for medicine. Nuclear magnetic resonance (NMR) was first observed in the hydrogen nucleus in water by Bloch, Purcell and Pound over 40 years ago. Today, in medicine, virtually all commercial MRI scans are made of water bound in tissue. This is also true for NMR microscopy, which has focussed mainly on biological applications. The reason water is the favored molecule for NMR is because water is,the most abundant molecule in biology. It is also the most NMR sensitive having the largest nuclear magnetic moment and having reasonable room temperature relaxation times (from 10 ms to 3 sec). The contrast seen in magnetic resonance images is due mostly to distribution of water relaxation times in sample which are extremely sensitive to the local environment.


Author(s):  
Alan P. Koretsky ◽  
Afonso Costa e Silva ◽  
Yi-Jen Lin

Magnetic resonance imaging (MRI) has become established as an important imaging modality for the clinical management of disease. This is primarily due to the great tissue contrast inherent in magnetic resonance images of normal and diseased organs. Due to the wide availability of high field magnets and the ability to generate large and rapidly switched magnetic field gradients there is growing interest in applying high resolution MRI to obtain microscopic information. This symposium on MRI microscopy highlights new developments that are leading to increased resolution. The application of high resolution MRI to significant problems in developmental biology and cancer biology will illustrate the potential of these techniques.In combination with a growing interest in obtaining high resolution MRI there is also a growing interest in obtaining functional information from MRI. The great success of MRI in clinical applications is due to the inherent contrast obtained from different tissues leading to anatomical information.


Author(s):  
Masaru Itakura ◽  
Noriyuki Kuwano ◽  
Kensuke Oki

The low temperature phase of Pd5Ce (L-Pd5Ce) has a one-dimensional long period superstructure (1D-LPS) derived from Ll2. The periodic antiphase boundaries (APBs) are parallel to (110) planes and have a shift vector of 1/2[110]. Hereafter, the indices are referred to the basic lattices of Ll2 As insertion of the APB causes a change in composition, such an APB is called “non-conservative”. Then, a domain size M depends upon the Ce concentration in the alloy. It was found that M increases also with temperature. The temperature dependency of M is attributed to a change of the degree of order within the antiphase domains. In this work, morphology of the non-conservative APBs is observed to clarify the formation process of the 1D-LPS.The alloy of Pd-16.7 at%Ce was prepared by arc melting in argon atmosphere. Disc specimens made from the alloy ingot were first held at 985 K for 260 ks and quenched in iced water to obtain the state of M=∞ or Ll2, followed by annealing for various lengths of time. The annealing temperature was 873 K where the equilibrium value for M is about 3 in unit of (110) lattice spacing of Ll2. Observation was carried out using microscopes JEM-2000FX, JEM-4000EX (HVEM Lab., Kyushu Univ.) and JEM-2000EX (Dept. of Mater. Sci. Tech., Kyushu Univ.).


Author(s):  
D.J. Meyerhoff

Magnetic Resonance Imaging (MRI) observes tissue water in the presence of a magnetic field gradient to study morphological changes such as tissue volume loss and signal hyperintensities in human disease. These changes are mostly non-specific and do not appear to be correlated with the range of severity of a certain disease. In contrast, Magnetic Resonance Spectroscopy (MRS), which measures many different chemicals and tissue metabolites in the millimolar concentration range in the absence of a magnetic field gradient, has been shown to reveal characteristic metabolite patterns which are often correlated with the severity of a disease. In-vivo MRS studies are performed on widely available MRI scanners without any “sample preparation” or invasive procedures and are therefore widely used in clinical research. Hydrogen (H) MRS and MR Spectroscopic Imaging (MRSI, conceptionally a combination of MRI and MRS) measure N-acetylaspartate (a putative marker of neurons), creatine-containing metabolites (involved in energy processes in the cell), choline-containing metabolites (involved in membrane metabolism and, possibly, inflammatory processes),


Author(s):  
B. G. Demczyk

CoCr thin films have been of interest for a number of years due to their strong perpendicular anisotropy, favoring magnetization normal to the film plane. The microstructure and magnetic properties of CoCr films prepared by both rf and magnetron sputtering have been examined in detail. By comparison, however, relatively few systematic studies of the magnetic domain structure and its relation to the observed film microstructure have been reported. In addition, questions still remain as to the operative magnetization reversal mechanism in different film thickness regimes. In this work, the magnetic domain structure in magnetron sputtered Co-22 at.%Cr thin films of known microstructure were examined by Lorentz transmission electron microscopy. Additionally, domain nucleation studies were undertaken via in-situ heating experiments.It was found that the 50 nm thick films, which are comprised of columnar grains, display a “dot” type domain configuration (Figure 1d), characteristic of a perpendicular magnetization. The domain size was found to be on the order of a few structural columns in diameter.


Author(s):  
Paul C. Lauterbur

Nuclear magnetic resonance imaging can reach microscopic resolution, as was noted many years ago, but the first serious attempt to explore the limits of the possibilities was made by Hedges. Resolution is ultimately limited under most circumstances by the signal-to-noise ratio, which is greater for small radio receiver coils, high magnetic fields and long observation times. The strongest signals in biological applications are obtained from water protons; for the usual magnetic fields used in NMR experiments (2-14 tesla), receiver coils of one to several millimeters in diameter, and observation times of a number of minutes, the volume resolution will be limited to a few hundred or thousand cubic micrometers. The proportions of voxels may be freely chosen within wide limits by varying the details of the imaging procedure. For isotropic resolution, therefore, objects of the order of (10μm) may be distinguished.Because the spatial coordinates are encoded by magnetic field gradients, the NMR resonance frequency differences, which determine the potential spatial resolution, may be made very large. As noted above, however, the corresponding volumes may become too small to give useful signal-to-noise ratios. In the presence of magnetic field gradients there will also be a loss of signal strength and resolution because molecular diffusion causes the coherence of the NMR signal to decay more rapidly than it otherwise would. This phenomenon is especially important in microscopic imaging.


Sign in / Sign up

Export Citation Format

Share Document