Proportional-resonant control method of three-phase grid-connected inverter

Author(s):  
Yumei Liu ◽  
Rui Bai ◽  
Daoqian Wang ◽  
Wenge Ma ◽  
Lin Wang
2013 ◽  
Vol 732-733 ◽  
pp. 1261-1264
Author(s):  
Zhi Lei Yao ◽  
Lan Xiao ◽  
Jing Xu

An improved control strategy for three-phase grid-connected inverters with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d-and q-axes grid currents is interacted in the traditional control method, and the waveform quality of the grid current is poor. As the reference output voltage cannot directly reflect the change of the reference grid current with the traditional control strategy, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d-and q-axes grid currents in the decoupled components of the grid current controller are substituted by the d-and q-axes reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results show that the grid-connected inverter with the improved control strategy has high waveform quality of the grid current and fast dynamic response.


2012 ◽  
Vol 241-244 ◽  
pp. 636-640
Author(s):  
Wu Wu Tang ◽  
Liang Liang Chen ◽  
Hong Xu Yin ◽  
Hao Dong

This paper developed a mathematical model of three-phase PV grid-connected inverter, and studied the grid-connected current control method based on PI control in synchronous rotating reference frame. Simulation and experimental results from the prototype of 30kW three-phase PV grid-connected inverter proved the correctness and the feasibility of the control strategy, and this grid-connected inverter can operate at the unity power factor state with a nice dynamic performance, and the output current has high sinusoidal and low harmonic content as well as good symmetry.


2013 ◽  
Vol 415 ◽  
pp. 81-88
Author(s):  
Yang Xue ◽  
Yuan Li ◽  
Jia Dong Zhang ◽  
Jing Lin ◽  
Jun Tao Yang

The space vector pulse width modulation (SVPWM), as a new kind of vector control technique, has the advantages of high voltage utilization, less distorted output, simple control method, etc. In this paper, the control technique is applied to three-phase photovoltaic (PV) grid-connected inverter system. It uses double loop control method combined with PI control technique. The simulation model of PV grid-connected inverter system is established in Matlab/Simulink. The simulation results show that the application of SVPWM technique effectively improves the dynamic performance of PV grid inverter system and the THD of grid-connected current is low.


2019 ◽  
Vol 115 ◽  
pp. 01006
Author(s):  
Amirreza Naderipour ◽  
Zulkurnain Abdul-Malek ◽  
Vigna K. Ramachandaramurthy ◽  
Josep. M. Guerrero

Microgrids (MGs) are developing owing to the rapidly growing distributed power generation systems. The MG controls the flexibility of the network to ensure the requirements of reliability and power quality are satisfied. A typical MG normally consists of dispersed generation resources, which are connected by power electronic inverters, storages, and non-linear loads. This study deals with a compensation control method of a photovoltaic grid-connected inverter using unity power factor (UPF) strategy in MG. In this case, the proposed control method can provide output currents without distortion and with the UPF. Further, it is able to increase the inverter output current to approximately 19 times of the value obtained conventionally. The proposed control method can be applied to three-phase grid interfaced converters such as DG inverters and can also be easily integrated into the conventional control scheme without installation of extra hardware. A theoretical analysis is presented and the performance of the proposed control method for a grid-connected inverter in a MG is evaluated through simulation results.


2011 ◽  
Vol 347-353 ◽  
pp. 591-600
Author(s):  
Nguyen Viet Ngu ◽  
Hong Hua Wang ◽  
Le Thi Minh Tam

The control objective of three-phase photovoltaic (PV) grid-connected inverter is to generate high quality and stable AC sinusoidal output power with the same phase angle, frequency and amplitude compatible with the grid-connected voltage. To overcome the shortcoming of the normal current PWM control method and traditional PI algorithm, this paper researches a combined control strategy of three phase PV grid-connected inverter based on fuzzy PI controller. The combined control strategy switches different PWM current control method among the hysteretic PWM, SVPWM, hysteretic current SVPWM according to the error between command current and feedback current,and the d-axis command current is output of fuzzy PI controller of DC bus voltage. The simulation model of the combined control strategy for three phase PV grid-connected inverter based on normal PI controller is built with Matlab, simulation results verified the combination control strategy based on fuzzy PI controller has excellent performances.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2754
Author(s):  
Mengmeng Xiao ◽  
Shaorong Wang ◽  
Zia Ullah

Three-phase imbalance is a long-term issue existing in low-voltage distribution networks (LVDNs), which consequently has an inverse impact on the safe and optimal operation of LVDNs. Recently, the increasing integration of single-phase distributed generations (DGs) and flexible loads has increased the probability of imbalance occurrence in LVDNs. To overcome the above challenges, this paper proposes a novel methodology based on the concept of "Active Asymmetry Energy-Absorbing (AAEA)" utilizing loads with a back-to-back converter, denoted as “AAEA Unit” in this paper. AAEA Units are deployed and coordinated to actively absorb asymmetry power among three phases for imbalance mitigation in LVDNs based on the high-precision, high-accuracy, and real-time distribution-level phasor measurement unit (D-PMU) data acquisition system and the 5th generation mobile networks (5G) communication channels. Furthermore, the control scheme of the proposed method includes three control units. Specifically, the positive-sequence control unit is designed to maintain the voltage of the DC-capacitor of the back-to-back converter. Likewise, the negative-sequence and zero-sequence control units are expected to mitigate the imbalanced current components. A simple imbalanced LVDN is modeled and tested in Simulink/Matlab (MathWorks, US). The obtained results demonstrate the effectiveness of the proposed methodology.