High performance controller design with PD feedback inner loop for three-phase four-leg inverter

Author(s):  
Changliang Liu ◽  
Fengxiang Wang ◽  
Haoran Bai
Author(s):  
M. M. S. Khan ◽  
M. S. Arifin ◽  
M. H. Rahaman ◽  
I. K. Amin ◽  
M. R. T. Hossain ◽  
...  
Keyword(s):  

2014 ◽  
Vol 116 ◽  
pp. 276-283 ◽  
Author(s):  
Naji Rajai Nasri Ama ◽  
Wilson Komatsu ◽  
Lourenco Matakas Junior

2016 ◽  
Vol 78 (6-2) ◽  
Author(s):  
Maher. G. M. Abdolrasol ◽  
M A Hannan ◽  
Azah Mohamed

This paper explains a deep comparison between two controller techniques firstly controller control on modulation index and the second controller use dq method. Both of these controller approaches have control on three phase voltage and use the same system unchanged. The system is a solar system together with a backup battery connected to a single housing unit. Particle Swarm Optimization (PSO) algorithm has been utilized to improve the controller performance by automatically finding its parameters in order to reduce the error in the proportional Integral (PI) controller. Optimization process has been done with a real recording data of housing unit demand in Malaka, Malaysia. System has been simulated and tested in MATLAB/Simulink environment with m-file runs PSO algorithm and simulate the system hundreds of times to get the best results showing in this paper. Comparisons were taking place in controller design and in the simulation results that express the strength and weaken points of each controller starts with THD voltage and current waveform and RMS voltage in each controller.  


Author(s):  
J. Lamterkati ◽  
L. Ouboubker ◽  
M. Khafallah ◽  
A. El afia

<p><span>The study made in this paper concerns the use of the voltage-oriented control (VOC) of three-phase pulse width modulation (PWM) rectifier with constant switching frequency. This control method, called voltage-oriented controlwith space vector modulation (VOC-SVM). The proposed control scheme has been founded on the transformation between stationary (α-β) and and synchronously rotating (d-q) coordinate system, it is based on two cascaded control loops so that a fast inner loop controls the grid current and an external loop DC-link voltage, while the DC-bus voltage is maintained at the desired level and ansured the unity power factor operation. So, the stable state performance and robustness against the load’s disturbance of PWM rectifiers are boths improved. The proposed scheme has been implemented and simulated in MATLAB/Simulink environment. The control system of the VOC-SVM strategy has been built based on dSPACE system with DS1104 controller board. The results obtained show the validity of the model and its control method. Compared with the conventional SPWM method, the VOC-SVM ensures high performance and fast transient response.</span></p>


Sign in / Sign up

Export Citation Format

Share Document