Modelling of exciter's influence on characteristic oscillation frequencies field structures in dielectric resonance radiators

Author(s):  
E. Yakovenko
Author(s):  
I.N. Ivanova ◽  
◽  
A.B. Kleschenkov ◽  
A.M. Lerer ◽  
V.V. Makhno ◽  
...  

2013 ◽  
Vol 109 (10) ◽  
pp. 2505-2516 ◽  
Author(s):  
Fu-Zen Shaw ◽  
Yi-Fang Liao ◽  
Ruei-Feng Chen ◽  
Yu-Hsing Huang ◽  
Rick C. S. Lin

The contribution of the zona incerta (ZI) of the thalamus on spike-wave discharges (SWDs) was investigated. Chronic recordings of bilateral cortices, bilateral vibrissa muscle, and unilateral ZI were performed in Long-Evans rats to examine the functional role of SWDs. Rhythmic ZI activity appeared at the beginning of SWD and was accompanied by higher-oscillation frequencies and larger spike magnitudes. Bilateral lidocaine injections into the mystacial pads led to a decreased oscillation frequency of SWDs, but the phenomenon of ZI-related spike magnitude enhancement was preserved. Moreover, 800-Hz ZI microstimulation terminates most of the SWDs and whisker twitching (WT; >80%). In contrast, 200-Hz ZI microstimulation selectively stops WTs but not SWDs. Stimulation of the thalamic ventroposteriomedial nucleus showed no obvious effect on terminating SWDs. A unilateral ZI lesion resulted in a significant reduction of 7- to 12-Hz power of both the ipsilateral cortical and contralateral vibrissae muscle activities during SWDs. Intraincertal microinfusion of muscimol showed a significant inhibition on SWDs. Our present data suggest that the ZI actively modulates the SWD magnitude and WT behavior.


Author(s):  
Thomas Kinsey ◽  
Guy Dumas

A new concept of hydrokinetic turbine using oscillating hydrofoils to extract energy from water currents (tidal or gravitational) is presented, tested and analyzed in the present investigation. Due to its rectangular extraction plane, this technology is particularly well suited for river beds and shallow waters near the coasts. The present turbine is a 2 kW prototype, composed of two rectangular oscillating hydrofoils of aspect ratio 7 in a tandem spatial configuration. The pitching motion of each hydrofoil is coupled to their cyclic heaving motion through four-link mechanisms which effectively yield a one-degree-of-freedom system driving a speed-controlled electric generator. The turbine has been mounted on a custom-made pontoon boat and dragged on a lake at different velocities. Instantaneous extracted power has been measured and cycle-averaged for several water flow velocities and hydrofoil oscillation frequencies. Results are demonstrated to be self-consistent and validate our extensive 2D flow simulation database. The present data show optimal performances of the oscillating hydrofoils concept at a reduced frequency of about 0.12, at which condition the measured power extraction efficiency reaches 40% once the overall losses in the mechanical system are taken into account. Further measurements of power extraction with a single oscillating hydrofoil have also been performed by taking out the downstream hydrofoil of the tandem pair. Those measurements favorably compare, quantitatively, with available 3D CFD predictions. The 40% hydrodynamic efficiency of this first prototype exceeds expectation and reaches levels comparable to the best performances achievable with modern rotor-blades turbines. It thus demonstrates the promising potential of the oscillating hydrofoils technology to efficiently extract power from an incoming water flow.


1994 ◽  
Vol 116 (3) ◽  
pp. 627-632 ◽  
Author(s):  
Y. Kamotani ◽  
F.-B. Weng ◽  
S. Ostrach ◽  
J. Platt

An experimental study is made of natural convection oscillations in gallium melts enclosed by right circular cylinders with differentially heated end walls. Cases heated from below are examined for angles of inclination (φ) ranging from 0 deg (vertical) to 75 deg with aspect ratios Ar (height/diameter) of 2, 3, and 4. Temperature measurements are made along the circumference of the cylinder to detect the oscillations, from which the oscillatory flow structures are inferred. The critical Rayleigh numbers and oscillation frequencies are determined. For Ar=3 and φ = 0 deg, 30 deg the supercritical flow structures are discussed in detail.


Author(s):  
Ramin M. H. Khorasany ◽  
Stanley G. Hutton

In this paper, the effect of geometrical nonlinear terms, caused by a space fixed point force, on the frequencies of oscillations of a rotating disk with clamped-free boundary conditions is investigated. The nonlinear geometrical equations of motion are based on Von Karman plate theory. Using the eigenfunctions of a stationary disk as approximating functions in Galerkin’s method, the equations of motion are transformed into a set of coupled nonlinear Ordinary Differential Equations (ODEs). These equations are then used to find the equilibrium positions of the disk at different discrete blade speeds. At any given speed, the governing equations are linearized about the equilibrium solution of the disk under the application of a space fixed external force. These linearized equations are then used to find the oscillation frequencies of the disk considering the effect of large deformation. Using multi mode approximation and different levels of nonlinearity, the frequency response of the disk considering the effect of geometrical nonlinear terms are studied. It is found that at the linear critical speed, the nonlinear frequency of the corresponding mode is not zero. Results are presented that illustrate the effect of the magnitude of disk displacement upon the frequency response characteristics. It is also found that for each mode, including the effect of the geometrical nonlinear terms due to the applied load causes a separation in the frequency responses of its backward and forward traveling waves when the disk is stationary. This effect is similar to the effect of a space fixed constraint in the linear problem. In order to verify the numerical results, experiments are conducted and the results are presented.


2017 ◽  
Vol 13 (S334) ◽  
pp. 166-169
Author(s):  
P. E. Nissen ◽  
V. Silva Aguirre ◽  
J. Christensen-Dalsgaard ◽  
R. Collet ◽  
F. Grundahl ◽  
...  

AbstractHigh-precision abundances of elements have been derived from HARPS-N spectra of F and G main-sequence stars having ages determined from oscillation frequencies delivered by the Kepler mission. The tight relations between abundance ratios of refractory elements, e.g., [Mg/Fe] and [Y/Mg], and stellar age previously found for solar twin stars are confirmed. These relations provide new information on nucleosynthesis and Galactic evolution. Abundance ratios between volatile and refractory elements, e.g., [C/Fe] and [O/Fe], show on the other hand a significant scatter at a given age, which may be related to planet-star interactions. This is a potential problem for chemical tagging studies.


Author(s):  
Ross Johnson ◽  
Jonathan Maikell ◽  
David Bogard ◽  
Justin Piggush ◽  
Atul Kohli ◽  
...  

When a turbine blade passes through wakes from upstream vanes it is subjected to an oscillation of the direction of the approach flow resulting in the oscillation of the position of the stagnation line on the leading edge of the blade. In this study an experimental facility was developed that induced a similar oscillation of the stagnation line position on a simulated turbine blade leading edge. The overall effectiveness was evaluated at various blowing ratios and stagnation line oscillation frequencies. The location of the stagnation line on the leading edge was oscillated to simulate a change in angle of attack between α = ± 5° at a range of frequencies from 2 to 20 Hz. These frequencies were chosen based on matching a range of Strouhal numbers typically seen in an engine due to oscillations caused by passing wakes. The blowing ratio was varied between M = 1, M = 2, and M = 3. These experiments were carried out at a density ratio of DR = 1.5 and mainstream turbulence levels of Tu ≈ 6%. The leading edge model was made of high conductivity epoxy in order to match the Biot number of an actual engine airfoil. Results of these tests showed that the film cooling performance with an oscillating stagnation line was degraded by as much as 25% compared to the performance of a steady flow with the stagnation line aligned with the row of holes at the leading edge.


1998 ◽  
Vol 84 (5) ◽  
pp. 1520-1527 ◽  
Author(s):  
Ulrich Thome ◽  
Frank Pohlandt

In high-frequency oscillatory ventilation (HFOV), an adequate mean airway pressure is crucial for successful ventilation and optimal gas exchange, but air trapping cannot be detected by the usual measurement at the y piece. Intratracheal pressures produced by the high-frequency oscillators HFV-Infantstar (IS), Babylog 8000 (BL), and the SensorMedics 3100A (SM) [the latter with either 30% (SM30) or 50% (SM50) inspiratory time] were investigated in four anesthetized tracheotomized female piglets that were 1 day old and weighed 1.6–1.9 kg (mean 1.76 kg). The endotracheal tube was repeatedly clamped while the piglets were ventilated with an oscillation frequency of 10 Hz, and the airway pressure distal of the clamp was recorded as a measure of average intrapulmonary pressure during oscillation. Clamping resulted in a significant decrease of mean airway pressure when the piglets were ventilated with SM30(−0.86 cmH2O), BL (−0.66 cmH2O), and IS (−0.71 cmH2O), but airway pressure increased by a mean of 0.76 cmH2O with SM50. Intratracheal pressure, when measured by a catheter pressure transducer at various oscillation frequencies, was lower than at the y piece by 0.4–0.9 cmH2O (SM30), 0.3–3 cmH2O (BL), and 1–4.7 cmH2O (IS) but was 0.4–0.7 cmH2O higher with SM50. We conclude that the inspiratory-to-expiratory time (Ti/Te) ratio influences the intratracheal and intrapulmonary pressures in HFOV and may sustain a mean pressure gradient between the y piece and the trachea. A Ti/Te ratio < 1:1 may be useful to avoid air trapping when HFOV is used.


Sign in / Sign up

Export Citation Format

Share Document