Aegis low voltage power supply system

Author(s):  
M. C. Johnson
2011 ◽  
Vol 219-220 ◽  
pp. 1109-1112
Author(s):  
Man Yin Hu ◽  
Chao Du ◽  
Bo Yang

According to operation situation of power plant’s EP, the technical measures of energy saving in low-voltage power supply system have been analyzed over the years. Based on the classical theory of electrostatic precipitator and the operating status quo of EP, the paper has been focused on the principles of energy-saving and emission-reduction EP, established high-voltage current supply energy-saving and emission-reduction EP dust removal efficiency of mathematical models, analyzed energy saving and emission reduction technical measures of the low voltage device and proposed the technical solutions. It provided reference for design, adjustment, operation and energy saving of power plant’s EP.


2013 ◽  
Vol 860-863 ◽  
pp. 1914-1918
Author(s):  
Yi Rong Su ◽  
Jie Yu ◽  
Jun Liu ◽  
Gan Zhou ◽  
Li Ping Zhan ◽  
...  

In order to improve the level of automation and security of the low voltage power supply system, this paper proposed the calculation method of short-circuit current criterion under condition of protection action. Firstly, the impact of circuit breakers on the short-circuit current is analyzed. Then, the current criterion under condition of short-circuit protection are given. Finally, using a special case, the calculation process of aforementioned current criterion is given in detail.


2021 ◽  
Vol 6 (2) ◽  
pp. 121-127
Author(s):  
Thanh Lich Do

Alumina production is rather complex technological process of processing mineral raw materials that requires development of effective technological solutions, including in terms of efficiency of using electric energy. The paper is devoted to studying the power supply system of an alumina refinery inLam Dong Province,Vietnam. The tasks that need to be solved for improving the power quality in the power supply system were analyzed. It was shown that non-linear loads significantly degrade the power quality that in turn leads to equipment damage, malfunction and decreasing the refinery productivity. Models of the refinery power supply system were developed and, using which, the quality of power was assessed at the 6 kV voltage utility bus of the power supply system, as well as at the 6 kV and 0.4 kV buses of distribution substations of individual refinery’s subdivisions. Analysis of the simulation findings showed that the nonlinear loads lead to significant distortions of sinusoidal forms of voltages and currents, and decreasing the power factor. Based on the simulation results, it was concluded that voltage harmonics and current harmonics at nonlinear load at the low voltage buses of 0.4 kV and at the buses of 6 kV exceed the permissible limits of the harmonics in accordance with IEEEST519-1992 international standard. Proposals were developed for improving the power quality in the refinery power supply system. For suppressing higher harmonics of current and voltage, it was recommended to use special power quality regulators in the alumina refinery power supply system. It was proposed to use active harmonic filters as the power quality regulators. The proposed solutions allowed obtaining practically sinusoidal forms of voltages and currents in the alumina refinery power supply system.


Author(s):  
N. P. Badalyan ◽  
G. P. Kolesnik ◽  
S. G. Solovyova ◽  
Ye. A. Chaschin

ObjectivesThe aim of the study is to increase the energy efficiency of an arc furnace’s power supply system and low-voltage circuit. According to the aim of the research, the relevant tasks of determining the capacitor capacity for reactive power compensation and selecting a rational location for its installation are posed.MethodsWithin the framework of the previously developed concept of changing the parameters of the switching transformer in the series compensation circuit, issues of efficient use and consumption of electrical energy by a high power linear load under sinusoidal mode are considered. The installation of static compensators using a direct compensation method with automatic control including 12 stages of regulation is proposed as a means of increasing the efficiency of the arc furnace. Challenges involved in increasing the efficiency of electric power supply to alternating current arc furnaces using compensating reactive power in a low-voltage circuit are considered.ResultsThe viability of using the series compensation circuit of reactive power with the switching of capacitors in the winding of the higher voltage of the series switching transformer is demonstrated.ConclusionIt is shown that for efficient use and consumption of electric energy by highpower linear load under sinusoidal conditions, it is advisable to apply the series compensation of reactive power with the switching of capacitors in the winding of the higher voltage of the series switching transformer. This makes it possible to increase the efficiency coefficient of electric arc furnace power supply devices by reducing the power losses in the power supply system and in the furnace lowvoltage circuit by 1.6 times, as well as reducing the total load in the power transformer by 1.36 times.


Sign in / Sign up

Export Citation Format

Share Document