Continuum Robot Stiffness Under External Loads and Prescribed Tendon Displacements

2019 ◽  
Vol 35 (2) ◽  
pp. 403-419 ◽  
Author(s):  
Kaitlin Oliver-Butler ◽  
John Till ◽  
Caleb Rucker
2021 ◽  
Vol 11 (5) ◽  
pp. 2356
Author(s):  
Carlo Albino Frigo ◽  
Lucia Donno

A musculoskeletal model was developed to analyze the tensions of the knee joint ligaments during walking and to understand how they change with changes in the muscle forces. The model included the femur, tibia, patella and all components of cruciate and collateral ligaments, quadriceps, hamstrings and gastrocnemius muscles. Inputs to the model were the muscle forces, estimated by a static optimization approach, the external loads (ground reaction forces and moments) and the knee flexion/extension movement corresponding to natural walking. The remaining rotational and translational movements were obtained as a result of the dynamic equilibrium of forces. The validation of the model was done by comparing our results with literature data. Several simulations were carried out by sequentially removing the forces of the different muscle groups. Deactivation of the quadriceps produced a decrease of tension in the anterior cruciate ligament (ACL) and an increase in the posterior cruciate ligament (PCL). By removing the hamstrings, the tension of ACL increased at the late swing phase, while the PCL force dropped to zero. Specific effects were observed also at the medial and lateral collateral ligaments. The removal of gastrocnemius muscles produced an increase of tension only on PCL and lateral collateral ligaments. These results demonstrate how musculoskeletal models can contribute to knowledge about complex biomechanical systems as the knee joint.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2621
Author(s):  
Seunghwa Yang

Here, we systematically interrogate the effects of grafting single-walled (SWNT) and multi-walled carbon nanotubes (MWNT) to polymer matrices by using molecular dynamics (MD) simulations. We specifically investigate key material properties that include interfacial load transfer, alteration of nanotube properties, and dispersion of nanotubes in the polymer matrix. Simulations are conducted on a periodic unit cell model of the nanocomposite with a straight carbon nanotube and an amorphous polyethylene terephthalate (PET) matrix. For each type of nanotube, either 0%, 1.55%, or 3.1% of the carbon atoms in the outermost nanotubes are covalently grafted onto the carbon atoms of the PET matrix. Stress-strain curves and the elastic moduli of nanotubes and nanocomposites are determined based on the density of covalent grafting. Covalent grafting promotes two rivalling effects with respect to altering nanotube properties, and improvements in interfacial load transfer in the nanocomposites are clearly observed. The enhanced interface enables external loads applied to the nanocomposites to be efficiently transferred to the grafted nanotubes. Covalent functionalization of the nanotube surface with PET molecules can alter the solubility of nanotubes and improve dispersibility. Finally, we discuss the current limitations and challenges in using molecular modelling strategies to accurately predict properties on the nanotube and polymers systems studied here.


Author(s):  
Eñaut Ozaeta ◽  
Javier Yanci ◽  
Carlo Castagna ◽  
Estibaliz Romaratezabala ◽  
Daniel Castillo

The main aim of this paper was to examine the association between prematch well-being status with match internal and external load in field (FR) and assistant (AR) soccer referees. Twenty-three FR and 46 AR participated in this study. The well-being state was assessed using the Hooper Scale and the match external and internal loads were monitored with Stryd Power Meter and heart monitors. While no significant differences were found in Hooper indices between match officials, FR registered higher external loads (p < 0.01; ES: 0.75 to 5.78), spent more time in zone 4 and zone 5, and recorded a greater training impulse (TRIMP) value (p < 0.01; ES: 1.35 to 1.62) than AR. Generally, no associations were found between the well-being variables and external loads for FR and AR. Additionally, no associations were found between the Hooper indices and internal loads for FR and AR. However, several relationships with different magnitudes were found between internal and external match loads, for FR, between power and speed with time spent in zone 2 (p < 0.05; r = −0.43), ground contact time with zone 2 and zone 3 (p < 0.05; r = 0.50 to 0.60) and power, speed, cadence and ground contact time correlated with time spent in zone 5 and TRIMP (p < 0.05 to 0.01; r = 0.42 to 0.64). Additionally, for AR, a relationship between speed and time in zone 1 was found (p < 0.05; r = −0.30; CL = 0.22). These results suggest that initial well-being state is not related to match officials’ performances during match play. In addition, the Stryd Power Meter can be a useful device to calculate the external load on soccer match officials.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1281
Author(s):  
Min Kyoung Kim ◽  
Huy Viet Le ◽  
Dong Joo Kim

This study investigated the electromechanical response of smart ultra-high-performance concretes (smart UHPCs), containing fine steel slag aggregates (FSSAs) and steel fibers as functional fillers, under external loads corresponding to different measurement methods. Regardless of different measurement methods of electrical resistance, the smart UHPCs under compression showed a clear reduction in their electrical resistivity. However, under tension, their electrical resistivity measured from direct current (DC) measurement decreased, whereas that from alternating current (AC) measurement increased. This was because the electrical resistivity, from DC measurement, of smart UHPCs was primarily dependent on fiber crack bridging, whereas that from AC measurement was dependent on tunneling effects.


Author(s):  
Daniel Rojas-Valverde ◽  
José Pino-Ortega ◽  
Rafael Timón ◽  
Randall Gutiérrez-Vargas ◽  
Braulio Sánchez-Ureña ◽  
...  

The extensive use of wearable sensors in sport medicine, exercise medicine, and health has increased the interest in their study. That is why it is necessary to test these technologies’ efficiency, effectiveness, agreement, and reliability in different settings. Consequently, the purpose of this article was to analyze the magnetic, angular rate, and gravity (MARG) sensor’s test-retest agreement and reliability when assessing multiple body segments’ external loads during off-road running. A total of 18 off-road runners (38.78 ± 10.38 years, 73.24 ± 12.6 kg, 172.17 ± 9.48 cm) ran two laps (1st and 2nd Lap) of a 12 km circuit wearing six MARG sensors. The sensors were attached to six different body segments: left (MPLeft) and right (MPRight) malleolus peroneus, left (VLLeft) and right (VLRight) vastus lateralis, lumbar (L1-L3), and thorax (T2-T4) using a special neoprene suit. After a principal component analysis (PCA) was performed, the total data set variance of all body segments was represented by 44.08%–70.64% for the 1st PCA factor considering two variables, Player LoadRT and Impacts, on L1-L3, respectively. These two variables were chosen among three total accelerometry-based external load indicators (ABELIs) to perform the agreement and reliability tests due to their relevance based on PCAs for each body segment. There were no significant differences between laps in the Player LoadRT or Impacts ( p > 0.05, trivial). The intraclass correlation and lineal correlation showed a substantial to almost perfect over-time test consistency assessed via reliability in both Player LoadRT and Impacts. Bias and t-test assessments showed good agreement between Laps. It can be concluded that MARGs sensors offer significant test re-test reliability and good agreement when assessing off-road kinematics in the six different body segments.


Sign in / Sign up

Export Citation Format

Share Document