Swelling and Curling Behaviors of Articular Cartilage

1998 ◽  
Vol 120 (3) ◽  
pp. 355-361 ◽  
Author(s):  
L. A. Setton ◽  
H. Tohyama ◽  
V. C. Mow

A new experimental method was developed to quantify parameters of swelling-induced shape change in articular cartilage. Full-thickness strips of cartilage were studied in free-swelling tests and the swelling-induced stretch, curvature, and areal change were measured. In general, swelling-induced stretch and curvature were found to increase in cartilage with decreasing ion concentration, reflecting an increasing tendency to swell and “curl” at higher swelling pressures. An exception was observed at the articular surface, which was inextensible for all ionic conditions. The swelling-induced residual strain at physiological ionic conditions was estimated from the swelling-induced stretch and found to be tensile and from 3–15 percent. Parameters of swelling were found to vary with sample orientation, reflecting a role for matrix anisotropy in controlling the swelling-induced residual strains. In addition, the surface zone was found to be a structurally important element, which greatly limits swelling of the entire cartilage layer. The findings of this study provide the first quantitative measures of swelling-induced residual strain in cartilage ex situ, and may be readily adapted to studies of cartilage swelling in situ.

Author(s):  
Seonghun Park ◽  
Ramaswamy Krishnan ◽  
Steven B. Nicoll ◽  
Gerard A. Ateshian

Under physiological conditions of loading, articular cartilage is subjected to both compressive strains, normal to the articular surface, and tensile strains, tangential to the articular surface. Previous studies have shown that articular cartilage exhibits a much higher modulus in tension than compression. Theoretical analyses have suggested that this tension-compression nonlinearity enhances the magnitude of interstitial fluid pressurization during loading in unconfined compression, above a theoretical threshold of 33% of the average applied stress. The first hypothesis of this experimental study is that the peak fluid load support in unconfined compression is significantly greater than the 33% theoretical limit predicted for porous permeable tissues modeled with equal moduli in tension and compression [1]. The second hypothesis is that the peak fluid load support is higher at the articular surface side of the tissue samples than near the deep zone, because the disparity between the tensile and compressive moduli is greater at the surface zone.


1984 ◽  
Vol 13 (3) ◽  
pp. 153-156 ◽  
Author(s):  
D W L Hukins ◽  
R M Aspden ◽  
Y E Yarker

The gel phase of articular cartilage is reinforced by collagen fibrils. These fibrils have low flexural and torsional stiffness, but are able to provide reinforcement if deformation of the tissue increases their tensile stress. An estimate suggests that the lengths of collagen fibrils in articular cartilage are at least of the same order as their critical length so that tensile stress in the tissue will increase the stress in the fibrils rather than simply pull them out of the gel. In the surface zone the collagen fibrils are oriented so that the efficiency of reinforcement, η, is about 0.6 tangential to the surface; tension in the fibrils is thus able to withstand swelling pressure within the tissue whose condition for stability resembles that of a pressure vessel. Swelling pressure allows the tissue to support applied pressure. An intermediate zone has a roughly isotropic η value of about 0.2, while in the deep zone collagen fibrils appear to tie the cartilage to the subchondral bone; in this deep zone η has a value of about 0.6 perpendicular to the surface direction. There is also some preferred orientation of collagen fibrils in the plane of the articular surface within the surface zone; in patellar cartilage the preferred orientations can be related to the direction of stress which could be generated by movement of the joint.


2020 ◽  
Vol 8 (4_suppl3) ◽  
pp. 2325967120S0023
Author(s):  
Michael Chau ◽  
Ferenc Toth ◽  
Ameya Bendre ◽  
Alexandra Armstrong ◽  
Jeffrey Macalena ◽  
...  

Background: Immature articular cartilage (a.k.a. articular epiphyseal cartilage complex, AECC), serves dual functions as an articulating layer and surface growth plate. The AECC originates from an uninterrupted cartilaginous template during embryogenesis, presumably stemming from the same pool of progenitors, but it is unclear how the articulating layer is maintained throughout life, while the surface growth plate undergoes endochondral ossification. Hypothesis: The function and fate of chondrocytes in the AECC are not predetermined in the embryo, but instead can be influenced during development by biochemical and/or biomechanical stimuli in the cellular microenvironment. Methods: Microenvironments of the articulating layer and surface growth plate were switched in an in vivo goat model. Twelve 3-week-old goats were used. Osteochondral autografts were harvested from medial and lateral condyles and trochlea of the distal femur. Subchondral bone was removed (Figures 1A and 1B). Grafts were inverted and press-fit into select sites, which were full (condyles) or low (trochlea) weightbearing (Figures 1C through 1E). Animals were allowed ambulation and range of motion as tolerated. Two goats each were euthanized at 1, 2, 3, 6, 12, and 24 weeks postoperatively. Distal femurs were harvested and grafts were analyzed with trichrome staining and in situ hybridization for Col10, Col2, and Prg4. Results: All animals survived surgery, ambulated within 24 hours, and none exhibited signs of surgical site infection. Macroscopically, grafts at the trochlea and lateral condyle maintained a more cartilaginous appearance than those at the medial condyle, but all eventually developed an osseous appearance. Histologically, there was healing over time, with early grafts often containing areas of hemorrhage and occasionally necrosis, followed by formation of granulation tissue and subjacent myelofibrosis, with eventual invasion and ossification. At later timepoints, there was better graft incorporation at the articular surface without replacement by fibrosis at the medial condyle (Figure 2). In situ hybridization demonstrated some Prg4 positive cells and a decrease in Col10 expression at the articular surface (Figure 3). Conclusions: The synovial microenvironment may play a protective role against endochondral ossification. Some incorporation of epiphyseal cartilage into articular cartilage occurred at sites subjected to both compressive and shear forces. Data suggest the existence of local cytokines and/or matrix effects on chondrocytes that stimulate different cell functions and fates. A limitation of this study is its observational nature. Further understanding of articular chondrocyte differentiation and identification of key biochemical and/or biomechanical stimuli hold therapeutic promise for articular cartilage regeneration, repair, and replacement. [Figure: see text][Figure: see text][Figure: see text]


1998 ◽  
Vol 120 (5) ◽  
pp. 614-619 ◽  
Author(s):  
N. Mukherjee ◽  
J. S. Wayne

The in situ mechanical conditions of cartilage in the articulated knee were quantified during joint loading. Six porcine knees were subjected to a 445 N compressive load while cartilage deformations and contact pressures were measured. From roentgenograms, cartilage thickness before and during loading allowed the calculation of tissue deformation on the lateral femoral condyle at different times during the loading process. Contact pressures on the articular surface were measured with miniature fiber-optic pressure transducers. Results showed that the medial side of the lateral femoral condyle had higher contact pressures, as well as deformations. To begin to correlate the pressures and resulting deformations, the intrinsic material properties of the cartilage on the lateral condyle were obtained from indentation tests. Data from four normal control specimens indicated that the aggregate modulus of the medial side was significantly higher than in other areas of the condyle. These experimental measures of the in situ mechanical conditions of articular cartilage can be combined with theoretical modeling to obtain valuable information about the relative contributions of the solid and fluid phases to supporting the applied load on the cartilage surface (see Part II).


Author(s):  
D. Loretto ◽  
J. M. Gibson ◽  
S. M. Yalisove ◽  
R. T. Tung

The cobalt disilicide/silicon system has potential applications as a metal-base and as a permeable-base transistor. Although thin, low defect density, films of CoSi2 on Si(111) have been successfully grown, there are reasons to believe that Si(100)/CoSi2 may be better suited to the transmission of electrons at the silicon/silicide interface than Si(111)/CoSi2. A TEM study of the formation of CoSi2 on Si(100) is therefore being conducted. We have previously reported TEM observations on Si(111)/CoSi2 grown both in situ, in an ultra high vacuum (UHV) TEM and ex situ, in a conventional Molecular Beam Epitaxy system.The procedures used for the MBE growth have been described elsewhere. In situ experiments were performed in a JEOL 200CX electron microscope, extensively modified to give a vacuum of better than 10-9 T in the specimen region and the capacity to do in situ sample heating and deposition. Cobalt was deposited onto clean Si(100) samples by thermal evaporation from cobalt-coated Ta filaments.


Author(s):  
K. Barmak

Generally, processing of thin films involves several annealing steps in addition to the deposition step. During the annealing steps, diffusion, transformations and reactions take place. In this paper, examples of the use of TEM and AEM for ex situ and in situ studies of reactions and phase transformations in thin films will be presented.The ex situ studies were carried out on Nb/Al multilayer thin films annealed to different stages of reaction. Figure 1 shows a multilayer with dNb = 383 and dAl = 117 nm annealed at 750°C for 4 hours. As can be seen in the micrograph, there are four phases, Nb/Nb3-xAl/Nb2-xAl/NbAl3, present in the film at this stage of the reaction. The composition of each of the four regions marked 1-4 was obtained by EDX analysis. The absolute concentration in each region could not be determined due to the lack of thickness and geometry parameters that were required to make the necessary absorption and fluorescence corrections.


Author(s):  
D. Loretto ◽  
J. M. Gibson ◽  
S. M. Yalisove

The silicides CoSi2 and NiSi2 are both metallic with the fee flourite structure and lattice constants which are close to silicon (1.2% and 0.6% smaller at room temperature respectively) Consequently epitaxial cobalt and nickel disilicide can be grown on silicon. If these layers are formed by ultra high vacuum (UHV) deposition (also known as molecular beam epitaxy or MBE) their thickness can be controlled to within a few monolayers. Such ultrathin metal/silicon systems have many potential applications: for example electronic devices based on ballistic transport. They also provide a model system to study the properties of heterointerfaces. In this work we will discuss results obtained using in situ and ex situ transmission electron microscopy (TEM).In situ TEM is suited to the study of MBE growth for several reasons. It offers high spatial resolution and the ability to penetrate many monolayers of material. This is in contrast to the techniques which are usually employed for in situ measurements in MBE, for example low energy electron diffraction (LEED) and reflection high energy electron diffraction (RHEED), which are both sensitive to only a few monolayers at the surface.


2017 ◽  
Author(s):  
Younghee Lee ◽  
Daniela M. Piper ◽  
Andrew S. Cavanagh ◽  
Matthias J. Young ◽  
Se-Hee Lee ◽  
...  

<div>Atomic layer deposition (ALD) of LiF and lithium ion conducting (AlF<sub>3</sub>)(LiF)<sub>x</sub> alloys was developed using trimethylaluminum, lithium hexamethyldisilazide (LiHMDS) and hydrogen fluoride derived from HF-pyridine solution. ALD of LiF was studied using in situ quartz crystal microbalance (QCM) and in situ quadrupole mass spectrometer (QMS) at reaction temperatures between 125°C and 250°C. A mass gain per cycle of 12 ng/(cm<sup>2</sup> cycle) was obtained from QCM measurements at 150°C and decreased at higher temperatures. QMS detected FSi(CH<sub>3</sub>)<sub>3</sub> as a reaction byproduct instead of HMDS at 150°C. LiF ALD showed self-limiting behavior. Ex situ measurements using X-ray reflectivity (XRR) and spectroscopic ellipsometry (SE) showed a growth rate of 0.5-0.6 Å/cycle, in good agreement with the in situ QCM measurements.</div><div>ALD of lithium ion conducting (AlF3)(LiF)x alloys was also demonstrated using in situ QCM and in situ QMS at reaction temperatures at 150°C A mass gain per sequence of 22 ng/(cm<sup>2</sup> cycle) was obtained from QCM measurements at 150°C. Ex situ measurements using XRR and SE showed a linear growth rate of 0.9 Å/sequence, in good agreement with the in situ QCM measurements. Stoichiometry between AlF<sub>3</sub> and LiF by QCM experiment was calculated to 1:2.8. XPS showed LiF film consist of lithium and fluorine. XPS also showed (AlF<sub>3</sub>)(LiF)x alloy consists of aluminum, lithium and fluorine. Carbon, oxygen, and nitrogen impurities were both below the detection limit of XPS. Grazing incidence X-ray diffraction (GIXRD) observed that LiF and (AlF<sub>3</sub>)(LiF)<sub>x</sub> alloy film have crystalline structures. Inductively coupled plasma mass spectrometry (ICP-MS) and ionic chromatography revealed atomic ratio of Li:F=1:1.1 and Al:Li:F=1:2.7: 5.4 for (AlF<sub>3</sub>)(LiF)<sub>x</sub> alloy film. These atomic ratios were consistent with the calculation from QCM experiments. Finally, lithium ion conductivity (AlF<sub>3</sub>)(LiF)<sub>x</sub> alloy film was measured as σ = 7.5 × 10<sup>-6</sup> S/cm.</div>


Author(s):  
Hyoung H. Kang ◽  
Michael A. Gribelyuk ◽  
Oliver D. Patterson ◽  
Steven B. Herschbein ◽  
Corey Senowitz

Abstract Cross-sectional style transmission electron microscopy (TEM) sample preparation techniques by DualBeam (SEM/FIB) systems are widely used in both laboratory and manufacturing lines with either in-situ or ex-situ lift out methods. By contrast, however, the plan view TEM sample has only been prepared in the laboratory environment, and only after breaking the wafer. This paper introduces a novel methodology for in-line, plan view TEM sample preparation at the 300mm wafer level that does not require breaking the wafer. It also presents the benefit of the technique on electrically short defects. The methodology of thin lamella TEM sample preparation for plan view work in two different tool configurations is also presented. The detailed procedure of thin lamella sample preparation is also described. In-line, full wafer plan view (S)TEM provides a quick turn around solution for defect analysis in the manufacturing line.


Sign in / Sign up

Export Citation Format

Share Document