Consecutive-Photo Method to Measure Vapor Volume Flow Rate During Boiling From a Wire Immersed in Saturated Liquid

1998 ◽  
Vol 120 (3) ◽  
pp. 561-567 ◽  
Author(s):  
C. N. Ammerman ◽  
S. M. You

A photographic measurement technique is developed to quantify the vapor volume flow rate departing from a wire during boiling. The vapor flow rate is determined by measuring the volume of bubbles after departure from the boiling surface in consecutive frames of high-speed video. The measurement technique is more accurate and easier to implement than a previously developed photographic/laser Doppler anemometry (LDA) method. Use of the high-speed camera in place of a standard video camera eliminates the requirement for LDA-acquired bubble velocity measurements. The consecutive-photo method requires relatively few video images to be analyzed to obtain steady-state vapor volume flow rates. The volumetric flow rate data are used to calculate the latent heat transfer and, indirectly, sensible heat transfer which comprise the nucleate boiling heat flux. The measurement technique is applied to a 75-μm diameter platinum wire immersed in saturated FC-72.

1996 ◽  
Vol 118 (1) ◽  
pp. 117-123 ◽  
Author(s):  
C. N. Ammerman ◽  
S. M. You ◽  
Y. S. Hong

A unique method to determine the vapor volumetric flow rate above a heated wire utilizing a single photograph and laser-Doppler anemometry is developed and discussed. The volumetric flow rate is combined with additional analyses to determine the overall contributions to the total heat flux from four nucleate boiling heat transfer mechanisms (latent heat, natural convection, Marangoni flow, and microconvection). This method is applied to a 75-μm wire immersed in a saturated, highly wetting liquid (FC-72). Latent heat is identified as the dominant mechanism in the fully developed nucleate boiling regime.


2019 ◽  
Vol 89 (9) ◽  
pp. 1434
Author(s):  
В.А. Бузановский

The design and metrological characteristics of the acoustic flowmeter of a flow of a gaseous or liquid substance are considered. It is shown that the device has a simple design, is characterized by high accuracy (relative error of measuring the volume flow rate is less than 1%) and high speed (the time to determine the flow rate is not more than a few milliseconds).


Author(s):  
Hussein Maghrabie ◽  
Hamouda Mousa

Abstract Recent progress in nanotechnology has lead to a revolution in the automotive cooling system. In the present work, enhancement of car radiator thermal performance was investigated using different nanofluids named SiO2/water, ZnO/water nanofluids as cooling mediums. The present study mainly aims to investigate the impact of (5 wt.%) from SiO2 and ZnO nanoparticles (NPs) dispersed in water based on car radiator heat transfer with spherical and hexagonal morphology, respectively. The experiments were performed in two working conditions of the nanofluids i.e coolant temperature and volume flow rate, moreover the present results were compared with the previous studies. The experimental working conditions were set at coolant inlet temperature (tc,i) ranged from 45 oC to 80 oC and the coolant volume flow rate (V) ranged from 3.5 lit/min to 6.5 lit/min. The experimental results show that the hexagonal ZnO/water nanofluid was superior towards enhancement of car radiator thermal performance comparing to that of SiO2 NPs. Additionally, at 6.5 lit/min and 45 °C, the enhancements of car radiator effectiveness due to using SiO2 and ZnO based water nanofluids and compared with that for the based water were 13.9% and 16%, respectively. The present study used the multiple regression analysis (MRA) and hence empirical correlations are suggested to estimate the overall heat transfer coefficient (U) for all coolants as functions of volume flow rate (V) and the coolant inlet temperature (tc,i) with a maximum STDEV of ± 1.85%.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
A.M. Abd-Alla ◽  
S.M. Abo-Dahab ◽  
M.A. Abdelhafez ◽  
Esraa N. Thabet

PurposeThis article aims to describe the effect of an endoscope and heat transfer on the peristaltic flow of a Jeffrey fluid through the gap between concentric uniform tubes.Design/methodology/approachThe mathematical model of the present problem is carried out under long wavelength and low Reynolds number approximations. Analytical solutions for the velocity, temperature profiles, pressure gradient and volume flow rate are obtained.FindingsThe results indicate that the effect of the wave amplitude, radius ratio, Grashof number, the ratio of relaxation to retardation times and the radius are very pronounced in the phenomena. Also, a comparison of obtaining an analytical solution against previous literatures shows satisfactory agreement.Originality/valueAnalytical solutions for the velocity, temperature profiles, pressure gradient and volume flow rate are obtained. Numerical integration is performed to analyze the pressure rise and frictional forces on the inner and outer tubes.


Author(s):  
Markus Juling ◽  
Jonas Steinbock ◽  
Andreas Weissenbrunner

Precise volume flow rate measurements are very important for various industrial applications. Here, one problem is that the service conditions of a flow meter used in the field differ significantly from the conditions present during calibration. The working conditions such as the pressure, the temperature and the flow profile greatly increase the uncertainty of the flow rate measurement. To address this problem, a new laser-optical flow rate standard (LFS) was developed at the Physikalisch-Technische Bundesanstalt (PTB) that allows flow meters to be calibrated on site, thus greatly reducing the uncertainty of the flow rate measurement. For the LFS, the velocity profile within the pipe is measured with laser Doppler anemometry (LDA). The profile is then integrated to calculate the volume flow rate. Various improvements to LDA have made it possible to measure the flow rate with an uncertainty of less than 0.15 % (k = 2). A comparison of the LFS with the primary standard for thermal energy at PTB, which has an uncertainty of less than 0.04 % (k = 2), revealed a maximum deviation of 0.07 % for Reynolds numbers from 105 to 106, thus verifying the uncertainty of the LFS.


2021 ◽  
Vol 3 (4) ◽  
Author(s):  
Mohd Muzammil Zubair ◽  
Md. Seraj ◽  
Mohd. Faizan ◽  
Mohd Anas ◽  
Syed Mohd. Yahya

AbstractNanofluid as a transport medium displays a great potential in engineering applications involving heat transfer. In this paper, the execution of water and ethylene glycol-based TiO2 nanofluid as a radiator coolant is resolved experimentally. The convective heat transfer coefficient of TiO2/EG-Water nanocoolant has been estimated and contrasted with the information acquired experimentally. Nanocoolant were set up by taking 25% ethylene glycol and 75% water with low volume concentration of TiO2 nanoparticles. All the experiments were led for the distinctive volume flow rates in the range going from 30 to 180 L/h (LPH). The nanocoolant made to flow through curved radiator tubes in every experiment, so that it can exchange heat effectively. Result shows that increasing the volume flow rate of nanocoolant flowing in the radiator tubes, increases the heat transfer as well as the convective heat transfer coefficient of nanocooant. Maximum heat transfer enhancement of 29.5% was recorded for nanocoolant with 0.03% nanoparticle concentration as compared to water at 150 LPH. Apart from this nanoparticle concentration into the base fluid, no further enhancement in heat transfer has been observed at any volume flow rate.


Author(s):  
Shuaihui Sun ◽  
Wang Zhe ◽  
Li Liansheng ◽  
Bu Gaoxuan

The two-phase suction injection can reduce the discharge temperature of scroll refrigeration compressors, which work under a high-pressure ratio. The heat transfer along the pipe axis from the shell affects the two-phase suction injection significantly for the compressor with a high-temperature shell. In this paper, the suction mixing and heat transfer model was developed to calculate the heat transfer along the pipe axis from the high-temperature compressor shell. Then the model was coupled with the two-phase compressor model to obtain the compressor performance under different suction injection volume flow rates. The compressor with two-phase suction injection was tested under different injection volume flow rates to validate the model. The results indicated that the discharge temperature decreased by 2 °C when the mass injection ratio increased by 1%. As the injection volume flow rates increased, the total mass flow rate increased due to the reduction of the specific volume of the suction fluid; the input work decreased because of the reduction of specific work and the improvement of the motor's electric efficiency. The cooling capacity decreased since the cooling capacity of the injection refrigerant was wasted for cooling the suction process and the compressor shell, especially at high injection volume flow rates. The coefficient of performance reached the maximum value at the injection volume flow rate of 0.015 m3·h−1 and became lower than the coefficient of performance without injection when the injection volume flow rate raised to 0.035 m3·h−1. Hence, the two-phase suction injection can reduce the discharge temperature efficiently at low injection volume flow rates with a slight improvement of coefficient of performance.


This paper documents the optimization of different parameters of micro channel heat sink which enhance the heat transfer. The objective is to find the major thermal resistance in micro channel and its effect on other parameters. Water is used as a coolant and the initial values of convective heat transfer coefficient and volume flow rate are 30000 W/m2K and 1 lpm respectively. Different graph are plotted between pressure drop,heat transfer co-efficient, pressure drop,thermal resistance and flow rate to finally achieve the optimized valus of channel width and height, hydraulic diameter, thermal resistance and pressure drop. The result achieved are in good agreement with the previous researches.


2020 ◽  
Vol 20 (2) ◽  
pp. 111-121
Author(s):  
Hadi O . Basher ◽  
Riyadh S Al-Turaihi ◽  
Ahmed A. Shubba

In this project, the flow distribution for air and water, and the enhancement of the heattransfer coefficient are experimentally studied. Experimental studies have been performed totest the influence of discharge, pitch, the height of ribs at a constant heat flux on thetemperature and pressure distributions. Along the channel of the test and the heat transfercoefficient, the water volume flow rate was about (5-12 L/min), the air volume flow rate wasabout (5.83-16.66 L/min), and heat were (80, 100,120, watt). An experimental rig wasconstructed within the test whole system. On the other hands, the channel has a divergentsection with an angle =15o with vertical axis. The study included changing in the ribs heightby using three values (12, 15, 18 mm) and changing the ribs pitch into three values (5, 8, 10mm).The results indicated an increasing in the local heat transfer coefficient as a result ofincreasing the discharge. While there was an inverse influence for the temperature distributionalong the test channel which drops when the discharge rise. The results also confirm that theincreasing in the pitch distance leads to reduce the heat transfer coefficient. Increasing theribs height increases the coefficient of heat transfer. However, the experiment heat transfercoefficient improves about (15.6 %) when the water volume flow rate increased from (5 to 12L/min), and about (18.7%) when the air volume flow rate increased from (5.83 to 16.66L/min). The best heat transfer coefficient was about (35.6 %) which can be achieved whenthe pitch decreased from (10 to 5mm). The increasing of the height from (12 to 18) mmimproves the heat transfer coefficient about (11.2 %). The best rib dimension was 18 mmheight, and 5 mm pitch, which give a maximum heat transfer coefficient (1212.02 W/m2. oC).


Sign in / Sign up

Export Citation Format

Share Document