Strain Uniformity in Biaxial Specimens is Highly Sensitive to Attachment Details

2009 ◽  
Vol 131 (9) ◽  
Author(s):  
Armin Eilaghi ◽  
John G. Flanagan ◽  
G. Wayne Brodland ◽  
C. Ross Ethier

Biaxial testing has been used widely to characterize the mechanical properties of soft tissues and other flexible materials, but fundamental issues related to specimen design and attachment have remained. Finite element models and experiments were used to investigate how specimen geometry and attachment details affect uniformity of the strain field inside the attachment points. The computational studies confirm that increasing the number of attachment points increases the size of the area that experiences sensibly uniform strain (defined here as the central sample region where the ratio of principal strains E11/E22<1.10), and that the strains experienced in this region are less than nominal strains based on attachment point movement. Uniformity of the strain field improves substantially when the attachment points span a wide zone along each edge. Subtle irregularities in attachment point positioning can significantly degrade strain field uniformity. In contrast, details of the apron, the region outside of the attachment points, have little effect on the interior strain field. When nonlinear properties consistent with those found in human sclera are used, similar results are found. Experiments were conducted on 6×6 mm talc-sprinkled rubber specimens loaded using wire “rakes.” Points on a grid having 12×12 bays were tracked, and a detailed strain map was constructed. A finite element model based on the actual geometry of an experiment having an off-pattern rake tine gave strain patterns that matched to within 4.4%. Finally, simulations using nonequibiaxial strains indicated that the strain field uniformity was more sensitive to sample attachment details for the nonequibiaxial case as compared to the equibiaxial case. Specimen design and attachment were found to significantly affect the uniformity of the strain field produced in biaxial tests. Practical guidelines were offered for design and mounting of biaxial test specimens. The issues addressed here are particularly relevant as specimens become smaller in size.




2000 ◽  
Author(s):  
Tammy Haut Donahue ◽  
Maury L. Hull ◽  
Mark M. Rashid ◽  
Christopher R. Jacobs

Abstract A finite element model of the tibio-femoral joint in the human knee was created using a new technique for developing accurate solid models of soft tissues (i.e. cartilage and menisci). The model was used to demonstrate that constraining rotational degrees of freedom other than flexion/extension when the joint is loaded in compression markedly affects the load distribution between the medial and lateral sides of the joint. The model also was used to validate the assumption that the bones can be treated as rigid.



Author(s):  
H. Lan ◽  
A. M. Al-Jumaily ◽  
A. Lowe

The human upper arm is simulated using a nonlinear geometrical and physical model. To create a more realistic simulation, the geometry of the model is based on the visible human body dataset. The model consists of four parts, humerus, brachial artery, muscle, and other soft tissues. All the materials used in this model are assumed to be incompressible and hyperelastic. The unique properties of each material are specified and described. Incorporating all of these facts, a finite element model is developed using the commercial programme ABAQUS®. The upper arm tissues’ deformations and artery collapse process under compression are simulated in this model. The proposed model has the potential to simulate the tissue deformations under inflatable cuffs exposed to arm movements.





Author(s):  
Rong Fan ◽  
Michael S. Sacks

Constitutive modeling is critical for numerical simulation and analysis of soft biological tissues. The highly nonlinear and anisotropic mechanical behaviors of soft tissues are typically due to the interaction of tissue microstructure. By incorporating information of fiber orientation and distribution at tissue microscopic scale, the structural model avoids ambiguities in material characterization. Moreover, structural models produce much more information than just simple stress-strain results, but can provide much insight into how soft tissues internally reorganize to external loads by adjusting their internal microstructure. It is only through simulation of an entire organ system can such information be derived and provide insight into physiological function. However, accurate implementation and rigorous validation of these models remains very limited. In the present study we implemented a structural constitutive model into a commercial finite element package for planar soft tissues. The structural model was applied to simulate strip biaxial test for native bovine pericardium, and a single pulmonary valve leaflet deformation. In addition to prediction of the mechanical response, we demonstrate how a structural model can provide deeper insights into fiber deformation fiber reorientation and fiber recruitment.





Author(s):  
Hongqiang Guo ◽  
Suzanne A. Maher ◽  
Robert L. Spilker

Biphasic theory which considers soft tissue, such as articular cartilage and meniscus, as a combination of a solid and a fluid phase has been widely used to model their biomechanical behavior [1]. Though fluid flow plays an important role in the load-carrying ability of soft tissues, most finite element models of the knee joint consider cartilage and the meniscus as solid. This simplification is due to the fact that biphasic contact is complicated to model. Beside the continuity conditions for displacement and traction that a single-phase contact problem consists of, there are two additional continuity conditions in the biphasic contact problem for relative fluid flow and fluid pressure [2]. The problem becomes even more complex when a joint is being modeled. The knee joint, for example, has multiple contact pairs which make the biphasic finite element model of this joint far more complex. Several biphasic models of the knee have been developed [3–9], yet simplifications were included in these models: (1) the 3D geometry of the knee was represented by a 2D axisymmetric geometry [3, 5, 6, 9]; (2) no fluid flow was allowed between contact surfaces of the soft tissues [4, 8] which is inconsistent with the equation of mass conservation across the contact interface [10]; (3) zero fluid pressure boundary conditions were inaccurately applied around the contact area [7].