Large Eddy Simulations for Film Cooling Assessment of Cylindrical and Laidback Fan-Shaped Holes With Reverse Injection

Author(s):  
Ashutosh Kumar Singh ◽  
Kuldeep Singh ◽  
Dushyant Singh ◽  
Niranjan Sahoo

Abstract The large eddy simulations (LES) are performed to access the film cooling performance of cylindrical and reverse shaped hole for forward and reverse injection configurations. In the case of reverse/backward injection, the secondary flow is injected in such a way that its axial velocity component is in the direction opposite to mainstream flow. The study is carried out for a blowing ratio (M = 1), density ratio (DR = 2.42), and injection angle (α = 35 deg). Formation of counter-rotating vortex pair (CRVP) is one of the major issues in the film cooling. This study revealed that the CRVP found in the case of forward cylindrical hole which promotes coolant jet “liftoff” is completely mitigated in the case of the reverse shaped hole. The coolant coverage for reverse cylindrical and reverse shaped holes is uniform and higher. The reverse shaped hole shows promising results among investigated configurations. The lateral averaged film cooling effectiveness of reverse shaped hole is 1.16–1.42 times higher as compared to the forward shaped holes. The improvement in the lateral averaged film cooling effectiveness of reverse cylindrical hole (RCH) injection over forward cylindrical hole (FCH) injection is 1.33–2 times.

Author(s):  
Christopher LeBlanc ◽  
Sridharan Ramesh ◽  
Srinath Ekkad ◽  
Mary Anne Alvin

In this study, effect of breakout angle of side holes from the main hole in a tripod hole design on film cooling performance is evaluated on a flat plate surface with steady-state IR (infrared thermography) technique. The designs are compared a cylindrical hole design inclined at 30° from the surface with pitch-to-diameter ratio of 3.0 and a shaped hole design, which is identical to the cylindrical hole design with the addition of adding a 10° flare and laydown to the exit on the mainstream surface. The two tripod hole designs are one where the two side holes, also of the same diameter, branch from the root at a 15° angle while maintaining the same 30° inclination as the cylindrical and shaped designs witha pitch-to-diameter ratio between the main holes for this design is 6.0. The other tripod hole design is a modified tripod hole design that increases the branch angle to 30°, which has the added effect of increasing the pitch-to-diameter ratio between the main holes to 7.5. Two secondary fluids — air and carbon-dioxide — were used to study the effects of coolant-to-mainstream density ratio (DR = 0.95 and 1.45) on film cooling effectiveness. Several blowing ratios in the range 0.5–4.0 were investigated independently at the two density ratios. Results show that the tripod hole design provides similar film cooling effectiveness as the shaped hole case with overall reduced coolant usage. Increasing the breakout angle from 15° to 30° reduces overall cooling effectiveness but increases jet-to-jet interactions.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2063
Author(s):  
Seung Il Baek ◽  
Jaiyoung Ryu ◽  
Joon Ahn

The forward expansion hole improves the film cooling effectiveness by reducing the penetration of the coolant jet into the main flow compared to the cylindrical holes. In addition, compound angles improve the film cooling effectiveness by promoting the lateral spreading of the coolant on a wall. Evidently, the combination of a compound angle and shaped hole further improves the adiabatic film cooling effectiveness. The film cooling flow with a shaped hole with 15° forward expansion, a 35° inclination angle, and 0° and 30° compound angles at 0.5 and 1.0 blowing ratios was numerically simulated with Large Eddy Simulations (LES) and Reynolds-averaged Navier–Stokes (RANS) simulations. The results of the time-averaged film cooling effectiveness, temperature, velocity, and root-mean-square (rms) values of the fluctuating velocity and temperature profiles were compared with the experimental data by Lee et al. (2002) to verify how the LES improves the results compared to those of the RANS. For the forward expansion hole, the velocity and temperature fluctuations in the LES contours are smaller than those of the cylindrical hole; thus, the turbulence and mixing intensity of the forward expansion hole are weaker and lower than those of the cylindrical hole, respectively. This leads to the higher film cooling effectiveness of the forward expansion hole. By contrast, the RANS contours do not exhibit velocity or temperature fluctuations well. These results are discussed in detail in this paper.


Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Charles P. Brown ◽  
Weston V. Harmon

A novel, double hole film cooling configuration is investigated as an alternative to traditional cylindrical and fanshaped, laidback holes. This experimental investigation utilizes a Stereo-Particle Image Velocimetry (S-PIV) to quantitatively assess the ability of the proposed, double hole geometry to weaken or mitigate the counter-rotating vortices formed within the jet structure. The three-dimensional flow field measurements are combined with surface film cooling effectiveness measurements obtained using Pressure Sensitive Paint (PSP). The double hole geometry consists of two compound angle holes. The inclination of each hole is θ = 35°, and the compound angle of the holes is β = ± 45° (with the holes angled toward one another). The simple angle cylindrical and shaped holes both have an inclination angle of θ = 35°. The blowing ratio is varied from M = 0.5 to 1.5 for all three film cooling geometries while the density ratio is maintained at DR = 1.0. Time averaged velocity distributions are obtained for both the mainstream and coolant flows at five streamwise planes across the fluid domain (x/d = −4, 0, 1, 5, and 10). These transverse velocity distributions are combined with the detailed film cooling effectiveness distributions on the surface to evaluate the proposed double hole configuration (compared to the traditional hole designs). The fanshaped, laidback geometry effectively reduces the strength of the kidney-shaped vortices within the structure of the jet (over the entire range of blowing ratios considered). The three-dimensional velocity field measurements indicate the secondary flows formed from the double hole geometry strengthen in the plane perpendicular to the mainstream flow. At the exit of the double hole geometry, the streamwise momentum of the jets is reduced (compared to the single, cylindrical hole), and the geometry offers improved film cooling coverage. However, moving downstream in the steamwise direction, the two jets form a single jet, and the counter-rotating vortices are comparable to those formed within the jet from a single, cylindrical hole. These strong secondary flows lift the coolant off the surface, and the film cooling coverage offered by the double hole geometry is reduced.


2021 ◽  
Vol 143 (2) ◽  
Author(s):  
Fu-qiang Wang ◽  
Jian Pu ◽  
Jian-hua Wang ◽  
Wei-dong Xia

Abstract Film-hole can be often blocked by thermal-barrier coatings (TBCs) spraying, resulting in the variations of aerodynamic and thermal performances of film cooling. In this study, a numerical study of the blockage effect on the film cooling effectiveness of inclined cylindrical-holes was carried out on a concave surface to simulate the airfoil pressure side. Three typical blowing ratios (BRs) of 0.5, 1.0, and 1.5 were chosen at an engine-similar density ratio (DR) of 2.0. Two common inclination angles of 30 deg and 45 deg were designed. The blockage ratios were adjusted from 0 to 20%. The results indicated the blockage could enhance the penetration of film cooling flow to the mainstream. Thus, the averaged effectiveness and coolant coverage area were reduced. Moreover, the pressure loss inside of the hole was increased. With the increase of BR, the decrement of film cooling effectiveness caused by blockage rapidly increased. At BR = 1.5, the decrement could be acquired up to 70% for a blockage ratio of 20%. The decrement of film cooling effectiveness caused by blockage was nearly nonsensitive to the injection angle; however, the larger angle could generate the higher increment of pressure loss caused by blockage. A new design method for the couple scheme of film cooling and TBC was proposed, i.e., increasing the inlet diameter according to the blockage ratio before TBC spraying. In comparison with the original unblocked-hole, the enlarged blocked-hole not only kept the nearly same area-averaged effectiveness but also reduced slightly the pressure loss inside of the hole. Unfortunately, application of enlarged blocked-hole at large BR could lead to a more obvious reduction of effectiveness near hole-exit, in comparison with the original common-hole.


Author(s):  
Aaron F. Shinn ◽  
S. Pratap Vanka

Large Eddy Simulations were performed to study the effect of a micro-ramp on an inclined turbulent jet interacting with a cross-flow in a film-cooling configuration. The micro-ramp vortex generator is placed downstream of the film-cooling jet. Changes in vortex structure and film-cooling effectiveness are evaluated and the genesis of the counter-rotating vortex pair in the jet is discussed. Results are reported with the jet modeled using a plenum/pipe configuration. This configuration was designed based on previous wind tunnel experiments at NASA Glenn Research Center, and the present results are meant to supplement those experiments. It is found that the micro-ramp improves film-cooling effectiveness by generating near-wall counter-rotating vortices which help entrain coolant from the jet and transport it to the surface. The pair of vortices generated by the micro-ramp are of opposite sense to the vortex pair embedded in the jet.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


Author(s):  
Bai-Tao An ◽  
Jian-Jun Liu ◽  
Si-Jing Zhou ◽  
Xiao-Dong Zhang ◽  
Chao Zhang

This paper presents a new configuration of discrete film hole, i.e., the slot-based diffusion hole. Retaining the similar diffusion features to a traditional diffusion hole, the slot-based diffusion hole transforms the cross section of circle for the traditional diffusion hole to a flattened rectangle with respect to the equivalent cross-sectional area. Consequently, the exit width of the new hole is effectively enlarged. To verify the film cooling effectiveness, a low speed flat plate experimental facility incorporated with Pressure Sensitive Paint (PSP) measurement technique was employed to obtain the adiabatic film cooling effectiveness. The experiments were performed with hole pitch to diameter ratio p/D=6 and density ratio DR=1.38. The blowing ratio was varied from M=0.5 to M=2.5. A fan-shaped hole and two slot-based diffusion holes were tested and compared. Three-dimensional numerical simulation was employed to analyze the flow field in detail. The experimental results showed that the area averaged effectiveness of two slot-based diffusion holes is significantly higher than that of the fan-shaped hole when the blowing ratio exceeds 1.0. The slot-based diffusion hole demonstrates the great advantage over the fan-shaped hole at hole exit and maintains this to far downstream. The numerical results showed that the ends shape of the flattened rectangular cross section has large influences on film distribution patterns and downstream vortex structures. The semi-circle and straight line ends shapes lead to a bi-peak and a single-peak effectiveness pattern, respectively. The optimal ends shape can regulate the vortex structures and improve the film cooling effectiveness further.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Baitao An ◽  
Jianjun Liu ◽  
Chao Zhang ◽  
Sijing Zhou

This paper presents a method to improve the film-cooling effectiveness of cylindrical holes. A short crescent-shaped block is placed at the downstream of a cylindrical cooling hole. The block shape is defined by a number of geometric parameters including block height, length and width, etc. The single row hole on a flat plate with inclination angle of 30 deg, pitch ratio of 3, and length-diameter ratio of 6.25 was chosen as the baseline test case. Film-cooling effectiveness for the cylindrical hole with or without the downstream short crescent-shaped block was measured by using the pressure sensitive paint (PSP) technique. The density ratio of coolant (argon) to mainstream air is 1.38. The blowing ratios vary from 0.5 to 1.25. The results showed that the lateral averaged cooling effectiveness is increased remarkably when the downstream block is present. The downstream short block allows the main body of the coolant jet to pass over the block top and to form a new down-wash vortex pair, which increases the coolant spread in the lateral direction. The effects of each geometrical parameter of the block on the film-cooling effectiveness were studied in detail.


Author(s):  
Kevin Liu ◽  
Shang-Feng Yang ◽  
Je-Chin Han

Adiabatic film-cooling effectiveness is examined systematically on a typical high pressure turbine blade by varying three critical flow parameters: coolant blowing ratio, coolant-to-mainstream density ratio, and freestream turbulence intensity. Three average coolant blowing ratios 1.0, 1.5, and 2.0; three coolant density ratios 1.0, 1.5, and 2.0; two turbulence intensities 4.2% and 10.5%, are chosen for this study. Conduction-free pressure sensitive paint (PSP) technique is used to measure film-cooling effectiveness. Three foreign gases — N2 for low density, CO2 for medium density, and a mixture of SF6 and Argon for high density are selected to study the effect of coolant density. The test blade features 45° compound-angle shaped holes on the suction side and pressure side, and 3 rows of 30° radial-angle cylindrical holes around the leading edge region. The inlet and the exit Mach number are 0.27 and 0.44, respectively. Reynolds number based on the exit velocity and blade axial chord length is 750,000. Results reveal that the PSP is a powerful technique capable of producing clear and detailed film effectiveness contours with diverse foreign gases. As blowing ratio exceeds the optimum value, it induces more mixing of coolant and mainstream. Thus film-cooling effectiveness reduces. Greater coolant-to-mainstream density ratio results in lower coolant-to-mainstream momentum and prevents coolant to lift-off; as a result, film-cooling increases. Higher freestream turbulence causes effectiveness to drop everywhere except in the region downstream of suction side. Results are also correlated with momentum flux ratio and compared with previous studies. It shows that compound shaped hole has the greatest optimum momentum flux ratio, and then followed by axial shaped hole, compound cylindrical hole, and axial cylindrical hole.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

In search of improved cooling of gas turbine blades, the thermal performances of two different film cooling hole geometries (horn-shaped and cylindrical) are investigated in this numerical study. The horn-shaped hole is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. The two hole shapes are evaluated singly and in tandem. The tandem geometry assumes three configurations made by locating the cylindrical hole at three different positions relative to the horn-shaped hole such that their two axes remain parallel to one another. One has the cylindrical hole downstream from the center of the horn-shaped hole, a second has the cylindrical hole to the left of (as seen by the flow emerging from the horn-shaped hole) and at the same streamwise location as the horn-shaped hole (θ = 90°) and the third has an intermediate geometry between those two geometries (downstream and to the left of the horn-shaped hole - θ = 45°). It is shown from the simulation results that the cooling effectiveness values for the θ = 45° and 90° cases are much better than that for θ = 0° (the first case), and the configuration with θ = 45° exhibits the best cooling performance of the three tandem arrangements. These improvements are attributed to the interaction of vortices from the two different holes, which weakens the counter-rotating vortex pairs inherent to film cooling jet to freestream interaction, counteracts with the lift forces, enhances transverse tensile forces and, thus, enlarges the film coverage zone by widening the flow attachment region. Overall, this research reveals that integration of horn-shaped and cylindrical holes provides much better film cooling effectiveness than cases where two cylindrical film cooling holes are applied with the same tandem configuration.