scholarly journals A Different Approach to Gas Turbine Exhaust Silencing

1974 ◽  
Author(s):  
Marv Weiss

A unique method for silencing heavy-duty gas turbines is described. The Switchback exhaust silencer which utilizes no conventional parallel baffles has at operating conditions measured attenuation values from 20 dB at 63 Hz to 45 dB at higher frequencies. Acoustic testing and analyses at both ambient and operating conditions are discussed.

Author(s):  
Lothar Bachmann ◽  
W. Fred Koch

The purpose of this paper is to update the industry on the evolutionary steps that have been taken to address higher requirements imposed on the new generation combined cycle gas turbine exhaust ducting expansion joints, diverter and damper systems. Since the more challenging applications are in the larger systems, we shall concentrate on sizes from nine (9) square meters up to forty (40) square meters in ducting cross sections. (Reference: General Electric Frame 5 through Frame 9 sizes.) Severe problems encountered in gas turbine applications for the subject equipment are mostly traceable to stress buckling caused by differential expansion of components, improper insulation, unsuitable or incompatible mechanical design of features, components or materials, or poor workmanship. Conventional power plant expansion joints or dampers are designed for entirely different operating conditions and should not be applied in gas turbine applications. The sharp transients during gas turbine start-up as well as the very high temperature and high mass-flow operation conditions require specific designs for gas turbine application.


Author(s):  
O. R. Schmoch ◽  
B. Deblon

The peripheral speeds of the rotors of large heavy-duty gas turbines have reached levels which place extremely high demands on material strength properties. The particular requirements of gas turbine rotors, as a result of the cycle, operating conditions and the ensuing overall concepts, have led different gas turbine manufacturers to produce special structural designs to resolve these problems. In this connection, a report is given here on a gas turbine rotor consisting of separate discs which are held together by a center bolt and mutually centered by radial serrations in a manner permitting expansion and contraction in response to temperature changges. In particular, the experience gained in the manufacture, operation and servicing are discussed.


1998 ◽  
Vol 120 (07) ◽  
pp. 72-73 ◽  
Author(s):  
Michael Valent

This article reviews that twenty-first century passengers on the Royal Caribbean International and Celebrity Cruises are set to make history in style. Up to six of Royal Caribbean’s Voyager- and Millennium-class vessels will be the first cruise ships ever powered by General Electric’s gas turbines. In addition to reducing engine-room noise and vibration and cutting emissions, this propulsion system—a departure from the traditional diesel engine—will make it possible for ships to set sail with a reduced maintenance crew and smaller parts inventory. Royal Caribbean International currently operates a fleet of 12 ships. In the Royal Caribbean application, the GE gas turbine will be used to drive generators that will provide electricity to propeller motors. The steam turbine will recover heat from the gas turbine exhaust for other uses. This combined gas turbine and steam turbine integrated electric drive system represents a departure from diesel engines in more than one respect.


1990 ◽  
Vol 112 (1) ◽  
pp. 80-85
Author(s):  
F. Fleischer ◽  
C. Koerner ◽  
J. Mann

Following repeated cases of damage caused to exhaust silencers located directly beyond gas turbine diffusers, this paper reports on investigations carried out to determine possible remedies. In all instances, an uneven exhaust gas flow distribution was found. The company’s innovative approach to the problem involved constructing a scale model of a complete gas turbine exhaust system and using it for flow simulation purposes. It was established for the first time that, subject to certain conditions, the results of tests conducted on a model can be applied to the actual turbine exhaust system. It is shown that when an unfavorable duct arrangement might produce an uneven exhaust flow, scale models are useful in the development of suitable flow-distributing devices.


Author(s):  
Luca Bozzi ◽  
Enrico D’angelo

High turn-down operating of heavy-duty gas turbines in modern Combined Cycle Plants requires a highly efficient secondary air system to ensure the proper supply of cooling and sealing air. Thus, accurate performance prediction of secondary flows in the complete range of operating conditions is crucial. The paper gives an overview of the secondary air system of Ansaldo F-class AEx4.3A gas turbines. Focus of the work is a procedure to calculate the cooling flows, which allows investigating both the interaction between cooled rows and additional secondary flows (sealing and leakage air) and the influence on gas turbine performance. The procedure is based on a fluid-network solver modelling the engine secondary air system. Parametric curves implemented into the network model give the consumption of cooling air of blades and vanes. Performances of blade cooling systems based on different cooling technology are presented. Variations of secondary air flows in function of load and/or ambient conditions are discussed and justified. The effect of secondary air reduction is investigated in details showing the relationship between the position, along the gas path, of the upgrade and the increasing of engine performance. In particular, a section of the paper describes the application of a consistent and straightforward technique, based on an exergy analysis, to estimate the effect of major modifications to the air system on overall engine performance. A set of models for the different factors of cooling loss is presented and sample calculations are used to illustrate the splitting and magnitude of losses. Field data, referred to AE64.3A gas turbine, are used to calibrate the correlation method and to enhance the structure of the lumped-parameters network models.


Author(s):  
Simone Cubeda ◽  
Tommaso Bacci ◽  
Lorenzo Mazzei ◽  
Simone Salvadori ◽  
Bruno Facchini ◽  
...  

Abstract Modern industrial gas turbines typically employ lean-premix combustors, which can limit pollutant emissions thanks to premixed flames, while sustaining high turbine inlet temperatures that increase the single-cycle thermal efficiency. As such, gas-turbine first stage nozzles can be characterized by a highly-swirled and temperature-distorted inlet flow field. However, due to several sources of uncertainty during the design phase, wide safety margins are commonly adopted, having a direct impact on engine performance and efficiency. Therefore, aiming at increasing the knowledge on combustor-turbine interaction and improving standard design practices, a non-reactive test rig composed of real hardware was assembled at the University of Florence, Italy. The rig, accommodating three lean-premix swirlers within a combustion chamber and two first stage film-cooled nozzles of a Baker Hughes heavy-duty gas turbine, is operated in similitude conditions. The rig has been designed to reproduce the real engine periodic flow field on the central vane channel, also allowing for measurements far enough from the lateral walls. The periodicity condition on the central sector was achieved by the proper design of both the angular profile and pitch value of the tailboards with respect to the vanes, which was carried out in a preliminary phase via a Design of Experiments procedure. In addition, circular ducts needed to be installed at the injectors outlet section to preserve the non-reactive swirling flow down to the nozzles’ inlet plane. The combustor-turbine interface section has been experimentally characterized in nominal operating conditions as per the temperature, velocity and pressure fields by means of a five-hole pressure probe provided with a thermocouple, installed on an automatic traverse system. To study the evolution of the combustor outlet flow through the vanes and its interaction with the film-cooling flow, such measurements have been replicated also downstream of the vanes’ trailing edge. This work allowed for designing and providing preliminary data on a combustor simulator capable of equipping and testing real hardware film-cooled nozzles of a heavy-duty gas turbine. Ultimately, the activity sets the basis for an extensive test campaign aimed at characterizing the metal temperature, film effectiveness and heat transfer coefficient at realistic aerothermal conditions. In addition, and by leveraging experimental data, this activity paves the way for a detailed validation of current design practices as well as more advanced numerical methodologies such as Scale-Adaptive Simulations of the integrated combustor-turbine domain.


Author(s):  
Matteo Cerutti ◽  
Luca Bozzi ◽  
Federico Bonzani ◽  
Carlo Carcasci

Combined cycle and partial load operating of modern heavy-duty gas turbines require highly efficient secondary air systems to supply both cooling and sealing air. Accurate performance predictions are then a fundamental demand over a wide range of operability. The paper describes the development of an efficient procedure for the investigation of gas turbine secondary flows, based on an in-house made fluid network solver, written in Matlab® environment. Fast network generation and debugging are achieved thanks to Simulink® graphical interface and modular structure, allowing predictions of the whole secondary air system. A crucial aspect of such an analysis is the calculation of blade and vane cooling flows, taking into account the interaction between inner and outer extraction lines. The problem is closed thanks to ad-hoc calculated transfer functions: cooling system performances and flow functions are solved in a pre-processing phase and results correlated to influencing parameters using Response Surface Methodology (RSM) and Design of Experiments (DOE) techniques. The procedure has been proved on the secondary air system of the AE94.3A2 Ansaldo Energia gas turbine. Flow functions for the cooling system of the first stage blade, calculated by RSM and DOE techniques, are presented. Flow functions based calculation of film cooling, tip cooling and trailing edge cooling air flows is described in details.


2011 ◽  
Vol 134 (4) ◽  
Author(s):  
Vladimir Vassiliev ◽  
Stefan Irmisch ◽  
Samer Abdel-Wahab ◽  
Andrey Granovskiy

The flow in exhaust diffusers along with the channel geometry strongly depends on the inflow conditions, including Mach number level, total pressure distribution, flow angle, and turbulence. In the first part of this paper, the impact of these parameters is analyzed using computational fluid dynamics, experimental data from the test rig, and field measurements. A widespread opinion is that the optimal condition for the diffuser is an axial uniform inflow. However, it is shown in this paper that nonuniform pressure distribution compared with a uniform one can lead to better diffuser performance and that a moderate residual swirl can improve the performance as well. In the second part of this paper, the minimization of exhaust losses in heavy-duty gas turbines is discussed and illustrated by two practical examples.


Author(s):  
V. Nayyeri ◽  
P. Asna Ashary

Repowering is increasing efficiency and output power of an existing steam power plants by integration them with gas turbine. Several approaches are proposed for repowering regards to condition of existing power plants. One of those approaches which provides opportunity for existing boiler reusing is windbox repowering. In this method, one or several gas turbines are installed near the existing steam unit and the exhaust of gas turbines is used as preheated combustion air for boiler. The main difficulty in integration of gas turbine and boiler is decreasing flame temperature in supplementary combustion of boiler due to low oxygen content of gas turbine exhaust compared with fresh air and its effect on heat transfer process especially in radiative sections. When advanced gas turbines are used in windbox repowering, the fresh air should be used for increasing oxygen due to low oxygen percent. In this study, the effect of using fresh air in wind box repowering will be investigated and two main arrangements, preheating and not preheating of fresh air will be compared. This study shows the advantages of using preheated air for mixing with gas turbine exhaust when advanced gas turbines are used for windbox repowering.


1982 ◽  
Vol 104 (1) ◽  
pp. 44-50 ◽  
Author(s):  
S. C. Hunter

Sulfur trioxide in gas turbine exhaust contributes to particulate emissions; reduction of this compound is a means for control of particulate emissions. The chemical kinetics of SO3 formation were analyzed for a large stationary gas turbine. The source of SO3 is the reaction of SO2 with oxygen atoms in the downstream end of the combustor primary zone. The primary zone produces SO3 levels of 1 to 2 percent of total SOx. SO3 increases above 1 to 2 percent during air dilution from an equivalence ratio of about 0.5 to 0.35; formation times are on the order of 1 to 10 ms. Reduction of primary zone air flow and more rapid dilution air mixing were identified as means for SO3 reduction. Dilution air mixing in 1 ms was identified as an objective; but would be a difficult task with current combustor designs.


Sign in / Sign up

Export Citation Format

Share Document