scholarly journals Semi Closed Gas Turbine Cycle and Humid Air Turbine: Thermoeconomic Evaluation of Cycle Performance and of the Water Recovery Process

Author(s):  
Andrea Corti ◽  
Bruno Facchini ◽  
Giampaolo Manfrida ◽  
Umberto Desideri

A comparison between power plants built according to the HAT (Humid Air Turbine) and SCGT/CC (Semi-Closed Gas Turbine/Combined Cycle) concepts is presented, ranging from thermodynamic performance (efficiency and specific power output) to projected data for plant construction and operating costs. Both options appear to be of potential interest to electric utilities considering advanced gas turbine power plants, with significant differences form the point of view of plant size, water consumption, and adaptability to advanced developments for the limitation of environmental impact (CO2 emissions).

Author(s):  
Toru Takahashi ◽  
Yutaka Watanabe ◽  
Hidefumi Araki ◽  
Takashi Eta

Humid air gas turbine systems that are regenerative cycle using humidified air can achieve higher thermal efficiency than gas turbine combined cycle power plant (GTCC) even though they do not require a steam turbine, a high combustion temperature, or a high pressure ratio. In particular, the advanced humid air gas turbine (AHAT) system appears to be highly suitable for practical use because its composition is simpler than that of other systems. Moreover, the difference in thermal efficiency between AHAT and GTCC is greater for small and medium-size gas turbines. To verify the system concept and the cycle performance of the AHAT system, a 3MW-class pilot plant was constructed that consists of a gas turbine with a two-stage centrifugal compressor, a two-stage axial turbine, a reverse-flow-type single-can combustor, a recuperator, a humidification tower, a water recovery tower, and other components. As a result of an operation test, the planned power output of 3.6MW was achieved, so that it has been confirmed the feasibility of the AHAT as a power-generating system. In this study, running tests on the AHAT pilot plant is carried out over one year, and various characteristics such as the effect of changes in ambient temperature, part-load characteristics, and start-up characteristics were clarified by analyzing the data obtained from the running tests.


2013 ◽  
Author(s):  
Yutaka Watanabe ◽  
Toru Takahashi

Recently, high efficiency and operational flexibility are required for thermal power plants to reduce CO2 emissions and to introduce renewable energy sources. We study the advanced humid air turbine (AHAT) system, which appears to be high suitable for practical use because its configuration is simpler than that of gas turbine combined cycle power plants (GTCCs). Moreover, the thermal efficiency of AHAT system for small and medium-size gas turbines is higher than that of GTCCs. To verify feasibility of this system and the cycle performance of AHAT system, a 3MW-class pilot plant was built in 2006 by Hitachi, Ltd., which mainly consists of a gas turbine, a water atomization cooling (WAC) system, a recuperator, a humidification tower and a water recovery tower. Through the operational test from 2006 to 2010, we confirmed the feasibility of the AHAT as a power-generation system, and various characteristics such as the effect of changes in ambient temperature, part-load characteristics, and start-up characteristics. Next step, a 40MW-class pilot plant was built in 2011 and started operational tests. This system mainly consists of a dual-shaft heavy duty gas turbine, a WAC system, a recuperator and a humidifier. As a result of the operational test, it has been confirmed that the pilot plant output achieved rated power output. In this paper, we show the 40MW-class pilot plant running test results, and evaluate thermal characteristics of this plant and the effect of WAC and humidification on performance of this gas turbine system.


2015 ◽  
Vol 5 (2) ◽  
pp. 89
Author(s):  
Munzer S. Y. Ebaid ◽  
Qusai Z. Al-hamdan

<p class="1Body">Several modifications have been made to the simple gas turbine cycle in order to increase its thermal efficiency but within the thermal and mechanical stress constrain, the efficiency still ranges between 38 and 42%. The concept of using combined cycle power or CPP plant would be more attractive in hot countries than the combined heat and power or CHP plant. The current work deals with the performance of different configurations of the gas turbine engine operating as a part of the combined cycle power plant. The results showed that the maximum CPP cycle efficiency would be at a point for which the gas turbine cycle would have neither its maximum efficiency nor its maximum specific work output. It has been shown that supplementary heating or gas turbine reheating would decrease the CPP cycle efficiency; hence, it could only be justified at low gas turbine inlet temperatures. Also it has been shown that although gas turbine intercooling would enhance the performance of the gas turbine cycle, it would have only a slight effect on the CPP cycle performance.</p>


Author(s):  
Mayank Maheshwari ◽  
Onkar Singh

Abstract Performance of gas/steam combined cycle power plants relies upon the performance exhibited by both gas based topping cycle and steam based bottoming cycle. Therefore, the measures for improving the performance of the gas turbine cycle and steam bottoming cycle eventually result in overall combined cycle performance enhancement. Gas turbine cooling medium affects the cooling efficacy. Amongst different parameters in the steam bottoming cycle, the deaerator parameter also plays its role in cycle performance. The present study analyzes the effect of deaerator’s operating pressure being varied from 1.6 bar to 2.2 bar in different configurations of simple and reheat gas/steam combined cycle with different cooling medium for fixed cycle pressure ratio of 40, turbine inlet temperature of 2000 K and ambient temperature of 303 K with varying ammonia mass fraction from 0.6 to 0.9. Analysis of the results obtained for different combined cycle configuration shows that for the simple gas turbine and reheat gas turbine-based configurations, the maximum work output of 643.78 kJ/kg of air and 730.87 kJ/kg of air respectively for ammonia mass fraction of 0.6, cycle efficiency of 54.55% and 53.14% respectively at ammonia mass fraction of 0.7 and second law efficiency of 59.71% and 57.95% respectively at ammonia mass fraction of 0.7 is obtained for the configuration having triple pressure HRVG with ammonia-water turbine at high pressure and intermediate pressure and steam turbine operating at deaerator pressure of 1.6 bar.


Author(s):  
Thorsten Lutsch ◽  
Uwe Gampe ◽  
Guntram Buchheim

Abstract Industrial combined heat and power (CHP) plants are often faced with highly variable demand of heat and power. Demand fluctuations up to 50% of nominal load are not uncommonly. The cost and revenue situation in the energy market represents a challenge, also for cogeneration of heat and power (CHP). More frequent and rapid load changes and a wide operating range are required for economic operation of industrial power plants. Maintaining pressure in steam network is commonly done directly by a condensation steam turbine in a combined cycle or indirectly by load changes of the gas turbine in a gas turbine and heat recovery steam generator arrangement. Both result in a change of the electric output of the plant. However, operating cost of a steam turbine are higher than a single gas turbine. The steam injected gas turbine (STIG) cycle with water recovery is a beneficial alternative. It provides an equivalent degree of freedom of power and heat generation. High process efficiency is achieved over a wide operating range. Although STIG is a proven technology, it is not yet widespread. The emphasis of this paper is placed on modeling the system behavior, process control and experiences in water recovery. A dynamic simulation model, based on OpenModelica, has been developed. It provides relevant information on system response for fluctuating steam injection and helps to optimize instrumentation and control. Considerable experience has been gained on water recovery with respect to condensate quality, optimum water treatment architecture and water recovery rate, which is also presented.


Author(s):  
Isaac Shnaid

The modem combined cycle power plants achieved thermal efficiency of 50–55% by applying bottoming multistage Rankine steam cycle. At the same time, the Brayton cycle is an attractive option for a bottoming cycle engine. In the author’s US Patent No. 5,442,904 is described a combined cycle system with a simple cycle gas turbine, the bottoming air turbine Brayton cycle, and the reverse Brayton cycle. In this system, air turbine Brayton cycle produces mechanic power using exergy of gas turbine exhaust gases, while the reverse Brayton cycle refrigerates gas turbine inlet air. Using this system, supercharging of gas turbine compressor becomes possible. In the paper, thermodynamic optimization of the system is done, and the system techno-economic characteristics are evaluated.


1983 ◽  
Vol 105 (4) ◽  
pp. 821-825 ◽  
Author(s):  
J. Wolf ◽  
S. Moskowitz

Studies of combined cycle electic power plants have shown that increasing the firing temperature and pressure ratio of the gas turbine can substantially improve the specific power output of the gas turbine as well as the combined cycle plant efficiency. Clearly this is a direction in which we can proceed to conserve the world’s dwindling petroleum fuel supplies. Furthermore, tomorrow’s gas turbines must do more than operate at higher temperature; they will likely face an aggressive hot gas stream created by the combustion of heavier oils or coal-derived liquid or gaseous fuels. Extensive tests have been performed on two rotating turbine rigs, each with a transpiration air cooled turbine operating in the 2600 to 3000°F (1427 to 1649°C) temperature range at increasing levels of gas stream particulates and alkali metal salts to simulate operation on coal-derived fuel. Transpiration air cooling was shown to be effective in maintaining acceptable metal temperatures, and there was no evidence of corrosion, erosion, or deposition. The rate of transpiration skin cooling flow capacity exhibited a minor loss in the initial exposure to the particulate laden gas stream of less than 100 hours, but the flow reduction was commensurate with that produced by normal oxidation of the skin material at the operating temperatures of 1350°F (732°C). The data on skin permeability loss from both cascade and engine tests compared favorably with laboratory furnace oxidation skin specimens. To date, over 10,000 hr of furnace exposure has been conducted. Extrapolation of the data to 50,000 hr indicates the flow capacity loss would produce an acceptable 50°F (10°C) increase in skin operating temperature.


Author(s):  
B. Facchini ◽  
G. Ferrara ◽  
G. Masi

The CHAT (Cascade Humid Air Turbine) cycle introduction has recently been proposed for a more simple and profitable application of the humid air turbine. The very interesting performance announced for this plant has been evaluated in this paper, particular attention is devoted to the multi-stage evaporation process and its thermodynamic limits. A detailed thermodynamic analysis of the most important cycle parameters, like various pressure levels, fire temperatures and blade coolant bleeding can permit the evaluation of better plant performances. The results show a substantial agreement with other published data and they confirm the good efficiency and high specific power of the CHAT cycle. Considering the proposed compressor and turbine for the CHAT plant an off design simulation of the plant is also realized to estimate the real behaviour of turbomachinery components. Moreover this study is based on ESMS code already developed by the authors and the new components model (thermodynamic, design and off-design simulation) introduced for this work are presented.


Author(s):  
Julianne M. Klara ◽  
Robert M. Enick ◽  
Scott M. Klara ◽  
Lawrence E. Van Bibber

The purpose of this study is to assess the feasibility of incorporating a Humid Air Turbine (HAT) into a coal-based, indirectly fired High Performance Power System (HIPPS). The HIPPS/HAT power plant exhibits a one percentage point greater thermal efficiency than the combined-cycle HIPPS plant. The capital costs for the HIPPS and HIPPS/HAT plants with identical net power output are nearly equivalent at $1380/kW. Levelized cost of electricity (COE) for the same size plants is 5.3 cents/kWh for the HIPPS plant and 5.4 cents/kWh for the HIPPS/HAT plant; the HIPPS/HAT plant improved thermal efficiency is offset by the higher fuel cost associated with a lower coal/natural gas fuel ratio. However, improved environmental performance is associated with the HIPPS/HAT cycle, as evidenced by lower CO2, SO2, and NOx emissions. Considering the uncertainties associated with the performance and cost estimates of the yet unbuilt components, the HIPPS/HAT and HIPPS power plants are presently considered to be comparable alternatives for future power generation technologies. The Department of Energy’s Combustion 2000 Program will provide revised design specifications and more accurate costs for these components allowing more definitive assessments to be performed.


Author(s):  
Yunhan Xiao ◽  
Rumou Lin ◽  
Ruixian Cai

The humid air turbine (HAT) cycle, proposed by Mori et al. and recently developed by Rao et al. at Flour Daniel, has been identified as a promising way to generate electric power at high efficiency, low cost and simple system relative to combined cycle and steam injection gas turbine cycle. It has aroused considerable interest. Thermodynamic means, such as intercooling, regeneration, heat recovery at low temperature and especially non-isothermal vaporisation by multi-phase and multi-component, are adopted in HAT cycle to reduce the external and internal exergy losses relative to the energy conversion system. In addition to the parameter analysis and the technical aspect of HAT cycle, there is also a strong need for “systems” research to identify the best ways, of configuring HAT cycle to integrate all the thermodynamic advantages more efficiently to achieve high performance. The key units in HAT cycle are analyzed thermodynamically and modelled in this paper. The superstructure containing all potentially highly efficient flowsheeting alternatives is also proposed. The system optimization of the HAT cycle is thus represented by a nonlinear programming problem. The problem is solved automatically by a successive quadratic algorithm to select the optimal configuration and optimal design parameters for the HAT cycle. The results have shown that the configuration of the HAT cycle currently adopted is not optimal for efficiency and/or specific power, and the current pressure ratio are too high to be favorable for highest performance. Based on the current technical practice, the optimal flowsheeting for thermal efficiency can reach 60.33% when TIT=1533K, while the optimal flowsheeting for specific power can achieve 1300kW/kg/s air for TIT at 1533K. The optimal flowsheeting configuration is compared favorably with the other existing ones.


Sign in / Sign up

Export Citation Format

Share Document