Numerical Simulation of Lubrication System in a Hermetic Reciprocating Compressor

Author(s):  
Mustafa Ozsipahi ◽  
Sertac Cadirci ◽  
Hasan Gunes ◽  
Kemal Sarioglu ◽  
Husnu Kerpicci

The aim of this numerical study is to investigate the lubrication system of a household hermetic reciprocating compressor. The effects of the rotational speed, oil viscosity and crankshaft-to-oil sump bottom distance on the oil-air two phase flows are investigated in detail. Necessary oil to lubricate the components of the compressor is sucked from the oil sump through an asymmetrically opened suction hole of the crankshaft by its rotational movement and climbs as an oil film on the helical channel carved on the shaft wall. This oil film is directed to crankshaft outlet. The oil forms an immiscible mixture with air, thus a two phase flow model should be analyzed using Volume of Fluid (VoF) method in the flow solver. Main findings related to the oil mass flow rate released from the crankshaft outlet reveal that with increasing rotational speed, the mass flow rate from the crankshaft outlet also increases, but with increasing viscosity and decreasing crankshaft-to-oil sump bottom distance, the oil mass flow rate decreases.

2020 ◽  
Vol 7 ◽  

The aim of this study is to numerically investigate theeffects of various parameters on the lubricant (oil)-coolant two phaseflow in the lubrication system of hermetic compressors commonlyused on household refrigerators. Lubrication oil is pumped from thesump through an asymmetrically opened hole on the bottom of thecrankshaft (suction side or inlet) by its rotational motion and climbsas an oil film on the internal surface of the helical channel carved onthe crankshaft surface. This oil film is directed to crankshaft upperexit discharging into the coolant refrigerant and it is used tolubricate the moving components of the compressor including thecylinder piston. The oil forms an immiscible mixture with coolant,thus a two phase flow model using Volume of Fluid (VOF) method isused. Specifically, the mass flow-rate of oil is determined as afunction of the rotational speed, oil viscosity and the submersiondepth of the crankshaft in the oil-sump. With increasing rotationalspeed and submersion depth, the mass flow-rate through thecrankshaft upper exit also increases. With increasing oil viscosity themass flow-rate through the crankshaft upper exit decreases due to theincreased friction.


Author(s):  
Sibel Tas ◽  
Sertac Cadirci ◽  
Hasan Gunes ◽  
Kemal Sarioglu ◽  
Husnu Kerpicci

The aim of this experimental study is to investigate the mass flow rate of the lubricating oil in a hermetic reciprocating compressor. Essential parameters affecting the performance of the lubrication are the rotational speed of the crankshaft, the viscosity of the oil, the operating temperature and the submersion depth of the crankshaft. An experimental setup was built as to measure the oil mass flow rate with respect to the oil temperature variation during different operating conditions. The influence of the governing parameters such as the rotational speed, temperature (viscosity) and the submersion depth on the mass flow rate from crankshaft outlet are studied in detail. In addition, the oil flow visualization from the upper hole of the crankshaft is performed using a high-speed camera in order to observe the effectiveness of the lubrication of the various parts of the compressor. This study reveals that with increasing rotational speed, the submersion depth of the crankshaft and with decreasing viscosity of the lubricant, the mass flow rate from the crankshaft increases.


2011 ◽  
Vol 110-116 ◽  
pp. 3657-3662
Author(s):  
S. Alikhani ◽  
A. Behzadmehr ◽  
S. Mirmasoumi

Fully developed laminar mixed convection of a nanofluid (water/Al2O3) in a horizontal curved tube is numerically investigated. Three-dimensional elliptic governing equations have been solved to show how nanoparticle concentration affects on thermal and hydrodynamic parameters while these parameters are impressed by centrifugal and buoyancy forces under constant mass flow rate and heat flux. Comparisons with previously published experimental works on horizontal curved tubes show good agreements between the results. Results which are obtained using the two – phase mixture model indicate that adding the nanoparticles causes changes in the properties of nanofluid and finally increases the temperature of the flow. Furthermore, increasing nanoparticles volume fraction at first augments the heat transfer coefficient of nanofluid and then, for higher concentration of particles, decreases this thermal parameter of nanofluid.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


Author(s):  
Mohammad J. Izadi ◽  
Alireza Falahat

In this investigation an attempt is made to find the best hub to tip ratio, the maximum number of blades, and the best angle of attack of an axial fan with flat blades at a fixed rotational speed for a maximum mass flow rate in a steady and turbulent conditions. In this study the blade angles are varied from 30 to 70 degrees, the hub to tip ratio is varied from 0.2 to 0.4 and the number of blades are varied from 2 to 6 at a fixed hub rotational speed. The results show that, the maximum flow rate is achieved at a blade angle of attack of about 45 degrees for when the number of blades is set equal to 4 at most rotational velocities. The numerical results show that as the hub to tip ratio is decreased, the mass flow rate is increased. For a hub to tip ratio of 0.2, and an angle of attack around 45 degrees with 4 blades, a maximum mass flow rate is achieved.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


Author(s):  
Nan Liang ◽  
Changqing Tian ◽  
Shuangquan Shao

As one kind of fluid machinery related to the two-phase flow, the refrigeration system encounters more problems of instability. It is essential to ensure the stability of the refrigeration systems for the operation and efficiency. This paper presents the experimental investigation on the static and dynamic instability in an evaporator of refrigeration system. The static instability experiments showed that the oscillatory period and swing of the mixture-vapor transition point by observation with a camera through the transparent quartz glass tube at the outlet of the evaporator. The pressure drop versus mass flow rate curves of refrigerant two phase flow in the evaporator were obtained with a negative slope region in addition to two positive slope regions, thus making the flow rate a multi-valued function of the pressure drop. For dynamic instabilities in the evaporation process, three types of oscillations (density wave type, pressure drop type and thermal type) were observed at different mass flow rates and heat fluxes, which can be represented in the pressure drop versus mass flow rate curves. For the dynamic instabilities, density wave oscillations happen when the heat flux is high with the constant mass flow rate. Thermal oscillations happen when the heat flux is correspondingly low with constant mass flow rate. Though the refrigeration system do not have special tank, the accumulator and receiver provide enough compressible volume to induce the pressure drop oscillations. The representation and characteristic of each oscillation type were also analyzed in the paper.


2021 ◽  
Author(s):  
Raghuvaran D. ◽  
Satvik Shenoy ◽  
Srinivas G

Abstract Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11-bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


Sign in / Sign up

Export Citation Format

Share Document