On the Response of a Strongly Diffusing Flow to Propagating Wakes

Author(s):  
J. P. Gostelow ◽  
R. L. Thomas ◽  
D. S. Adebayo

Further evidence on the similarities between transition and separation phenomena occurring in turbomachinery and wind tunnel flows is provided by measurements on a large scale flat plate under a strong adverse pressure gradient. The flat plate has a long laminar separation bubble and is subjected to a range of disturbances with triggering caused by injection of a transverse jet and subsequently by wakes generated by rods moving transversely upstream of the leading edge. Wakes were originally presented individually. Each individual wake provoked a vigorous turbulent patch, resulting in the instantaneous collapse of the separation bubble. This was followed by a very strong, and stable, calmed region. Following the lead given by the experiments of Gutmark and Blackwelder on triggered turbulent spots, wakes were then presented in pairs at different wake spacing intervals. In this way wake interaction effects could be investigated in more detail. As in the work on triggered turbulent spots the spacing between impinging wakes was systematically varied; it was found that for close wake spacings the calmed region acted to suppress the turbulence in the following turbulent patch. To investigate whether this phenomenon was a recurring one, or whether the flow then reverted back to its unperturbed state, the experiments were repeated with three and four rods instead of two. This has the potential for making available a wide range of variables including direction and speed of rod rotation. It was found that the subsequent wakes were also suppressed by the calming effect. It may be anticipated that this repeating situation is present in a turbomachine, resulting in hidden benefits for blade count and efficiency. There may also conceivably be blade loading advantages whilst retaining favorable heat transfer conditions in high pressure turbines or stall margin in axial compressors. The inherent and prospective benefits of the calming effect therefore need to be understood thoroughly and new opportunities exploited where this is feasible.

2009 ◽  
Vol 131 (2) ◽  
Author(s):  
J. P. Gostelow ◽  
R. L. Thomas ◽  
D. S. Adebayo

Further evidence on the similarities between transition and separation phenomena occurring in turbomachinery and wind tunnel flows is provided by measurements on a large scale flat plate under a strong adverse pressure gradient. The flat plate has a long laminar separation bubble and is subjected to a range of disturbances with triggering caused by injection of a transverse jet and subsequently by wakes generated by rods moving transversely upstream of the leading edge. Wakes were originally presented individually. Each individual wake provoked a vigorous turbulent patch, resulting in the instantaneous collapse of the separation bubble. This was followed by a very strong, and stable, calmed region. Following the lead given by the experiments of Gutmark and Blackwelder (1987, “On the Structure of Turbulent Spot in a Heated Laminar Boundary Layer,” Exp. Fluids, 5, pp. 207–229.) on triggered turbulent spots, wakes were then presented in pairs at different wake spacing intervals. In this way wake interaction effects could be investigated in more detail. As in the work on triggered turbulent spots the spacing between impinging wakes was systematically varied; it was found that for close wake spacings the calmed region acted to suppress the turbulence in the following turbulent patch. To investigate whether this phenomenon was a recurring one or whether the flow then reverted back to its unperturbed state, the experiments were repeated with three and four rods instead of two. This has the potential for making available a wide range of variables including direction and speed of rod rotation. It was found that the subsequent wakes were also suppressed by the calming effect. It may be anticipated that this repeating situation is present in a turbomachine, resulting in hidden benefits for blade count and efficiency. There may also conceivably be blade loading advantages while retaining favorable heat transfer conditions in high pressure turbines or stall margin in axial compressors. The inherent and prospective benefits of the calming effect therefore need to be understood thoroughly and new opportunities exploited where this is feasible.a


Author(s):  
A. Samson ◽  
S. Sarkar

The dynamics of separation bubble under the influence of continuous jets ejected near the semi-circular leading edge of a flat plate is presented. Two different streamwise injection angles 30° and 60° and velocity ratios 0.5 and 1 for Re = 25000 and 55000 (based on the leading-edge diameter) are considered here. The flow visualizations illustrating jet and separated layer interactions have been carried out with PIV. The objective of this study is to understand the mutual interactions of separation bubble and the injected jets. It is observed that flow separates at the blending point of semi-circular arc and flat plate. The separated shear layer is laminar up to 20% of separation length after which perturbations are amplified and grows in the second-half of the bubble leading to breakdown and reattachment. Blowing has significantly affected the bubble length and thus, turbulence generation. Instantaneous flow visualizations supports the unsteadiness and development of three-dimensional motions leading to formation of Kelvin-Helmholtz rolls and shedding of large-scale vortices due to jet and bubble interactions. In turn, it has been seen that both the spanwise and streamwise dilution of injected air is highly influenced by the separation bubble.


1997 ◽  
Vol 333 ◽  
pp. 403-413 ◽  
Author(s):  
W. W. H. YEUNG ◽  
G. V. PARKINSON

An inviscid analytic model is proposed for the steady separated flow around an inclined flat plate. With the plate normal to the stream, the model reduces to the wake-source model of Parkinson & Jandali originally developed for flow external to a symmetrical two-dimensional bluff body and its wake. At any other inclination, the Kutta condition is satisfied at both leading and trailing edges of the plate, and, in the limit that the angle of attack approaches zero, classical airfoil theory is recovered. A boundary condition is formulated based on some experimental results of Abernathy, but no additional empirical information is required. The predicted pressure distributions on the wetted surface for a wide range of angle attack are found to be in good agreement with experimental data, especially at smaller angles of attack. An extension to include a leading-edge separation bubble is explored and results are satisfactory.


Author(s):  
M J Crompton ◽  
R V Barrett

Detailed measurements of the separation bubble formed behind the sharp leading edge of a flat plate at low speeds and incidence are reported. The Reynolds number based on chord length ranged from 0.1 × 105 to 5.5 × 105. Extensive use of laser Doppler anemometry allowed detailed velocity measurements throughout the bubble. The particular advantages of laser Doppler anemometry in this application were its ability to define flow direction without ambiguity and its non-intrusiveness. It allowed the mean reattachment point to be accurately determined. The static pressure distribution along the plate was also measured. The length of the separation bubble was primarily determined by the plate incidence, although small variations occurred with Reynolds number because of its influence on the rate of entrainment and growth of the shear layer. Above about 105, the Reynolds number effect was no longer evident. The reverse flow boundary layer in the bubble exhibited signs of periodic stabilization before separating close to the leading edge, forming a small secondary bubble rotating in the opposite sense to the main bubble.


Author(s):  
Saeed Moaveni ◽  
Michael C. Watts

During the past few decades, a wide range of studies have been performed to improve the performance of flat plate solar collectors by either reducing the heat loss from a collector or by increasing the amount of solar radiation absorbed by the absorber plate. Examples of these studies include adding transparent honeycomb to fill the air gap between the glazing and absorber plate to reduce convective heat loss, replacing the air in the gap by other gases such as Argon, Krypton, Xenon and Carbon Dioxide, or adding a chemical coating such as Copper Oxide to increase absorbtance and reduce the emittance of the absorber plate. While these methods improve the collector’s efficiency, they focus primarily on limiting the natural convection that occurs in the collector cavity, or on improving the optical properties of the absorber or glazing. None of these studies have addressed the problem of heat loss due to forced convection to the surrounding ambient air in any detail. Yet, research has shown that forced convection will contribute significantly to the heat loss from a collector. Windbreaks have traditionally been used to direct wind to protect farmland, and to direct wind drifts and sand dunes. Windbreaks also have been shown to provide protection for homes from winter winds which result in reduced heating costs for buildings. While windbreaks have been traditionally used for large scale applications, there is reason to believe that similar benefits can be expected for scaled down applications such as adding a windbreak along side of a flat-plate solar collector. In this paper, we examine the feasibility of using a windbreak to provide a flat plate solar collector protection from the wind in order to improve its performance. A series of experiments were performed wherein the thermal performance of two flat-plate collectors — one without a windbreaker and one with a windbreaker — were measured. The results of these experiments are reported in this paper and the need for further studies to explore different windbreak configurations is discussed.


1987 ◽  
Vol 109 (2) ◽  
pp. 108-110 ◽  
Author(s):  
S. Shakerin

Experiments were performed to evaluate the convective heat transfer coefficient for a flat plate mounted in a wooden model of a roof of a building. The experiments were carried out in a closed-circuit wind tunnel and included parametric adjustments of the roof tilt and Reynolds number, based on the length of the plate. The roof tilt was set at 0, 30, 45, 60, and 90 degrees and the Reynolds number ranged from 58,000 to 250,000. A transient, one lump, thermal approach was used for heat transfer calculations. Due to a separation bubble at the leading edge of the model, i.e., the roof, at angles of attack of less than 40 degrees, the flow became turbulent after reattachment. This resulted in a higher heat transfer than previously reported in the literature. At higher angles of attack, the flow was not separated at the leading edge and remained laminar. The heat transfer coefficient for higher angles of attack, i.e., α > 40 deg, was found to be approximately independent of the angle of attack and in good agreement with the previously published results.


2021 ◽  
Vol 2103 (1) ◽  
pp. 012203
Author(s):  
E K Guseva ◽  
D A Nikulin ◽  
A K Travin ◽  
R Radespiel ◽  
P Scholz

Abstract Results are presented of a series of RANS computations aimed at creating a new experimental flow model of a curved turbulent wake evolving under adverse pressure gradient. In the course of the computations, key geometric parameters of the model (the angle of attack of a flat plate generating the wake and the shape and the angles of attack of liner foils creating the pressure gradient) were varied in a wide range. The purpose was to find the parameters ensuring desirable features of the flow, namely, a considerable wake curvature and its strong deceleration leading to formation of a large stagnation or even a reversal flow region, on the one hand, and no flow separation either from the flat plate or from the surfaces of the liner foils, on the other hand. As a result, the design satisfying all these demands has been found. This design will be implemented and studied in the framework of recently launched joint German-Russian project “Complex Wake Flows” which presents a continuation of an earlier similar project devoted to symmetric wakes.


Author(s):  
Sabine Ardey ◽  
Stefan Wolff ◽  
Leonhard Fottner

For a better understanding of the turbulence structures attached to film cooling jets, mean flow velocities and turbulent fluctuations were measured by means of 3D hot wire anemometry in the injection zone of a linear, large scale, high pressure turbine cascade with leading edge film cooling. Near the stagnation point, the blades are equipped with one row of film cooling holes each on the suction and pressure side. Two basically different coolant jet situations are compared: On the suction side the jet features the ordinary kidney vortex. On the pressure side, the jet separates completely from the blade surface since it is located above a large recirculation zone created by a locally adverse pressure gradient and a flow separation near the pressure side injection. The measured Reynolds stresses were analyzed with regard to turbulence production and diffusion. The Bousinesque Hypothesis was tested and could not be confirmed. It was found that the turbulence is highly anisotropic. In addition to the brief description of the experimental set up and the acquired data, given in this paper, the complete information are published as a test case (Ardey and Fottner, 1998) that is directly accessible via internet at: http://www.unibw-muenchen.de/campus/LRT12/welcome.html


2014 ◽  
Author(s):  
M. Grayson ◽  
E. Garcia

Wind power continues to be produced by large-scale wind farms in remote areas. Supplying urban areas requires that this power be transmitted over vast distances. Generating power locally in urban cities not only decreases transmission distances but reduces external demand by using the harvested energy on site. A crucial element in the use of wind in the built environment as a source of energy is finding ways to maximize its flow. As flow approaches the windward façade of a building’s structure, it is disturbed, causing an increase in velocity both at the roof’s edge and above the separation bubble. Energy harvesting devices are usually placed in this flow region. The aim of this study is to further investigate the accelerated flow by modifying the building’s structure to be a concentrator of the wind, thereby maximizing the available wind power. Using computational fluid dynamics, sloped façades at varying angles were investigated. Simulations show that at an angle of 30°, the velocity is amplified by more than 100% at the separation point directly above the roof’s leading edge. Currently, wind tunnel experiments simulating flow behavior are being conducted and it is expected that analysis of the data will validate and support the findings presented.


Sign in / Sign up

Export Citation Format

Share Document