scholarly journals Investigation of the Flow Field in the Vicinity of an Axial Flow Fan During Low Flow Rates

Author(s):  
Francois G. Louw ◽  
Theodor W. von Backström ◽  
Sybrand J. van der Spuy

Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.

2020 ◽  
Vol 142 (10) ◽  
Author(s):  
Hiroshi Yokoyama ◽  
Katsutake Minowa ◽  
Kohei Orito ◽  
Masahito Nishikawara ◽  
Hideki Yanada

Abstract Small axial fans are used for cooling electronic equipment and are often installed in a casing with various slits. Direct aeroacoustic simulations and experiments were performed with different casing opening ratios to clarify the effects of the flow through the casing slits on the flow field and acoustic radiation around a small axial fan. Both the predicted and measured results show that aerodynamic performance deteriorates at and near the design flow rate and is higher at low flow rates by completely closing the casing slits compared with the fan in the casing with slits. The predicted flow field shows that the vortical structures in the tip vortices are spread by the suppression of flow through the slits at the design flow rate, leading to the intensification of turbulence in the blade wake. Moreover, the pressure fluctuations on the blade surface are intensified, which increases the aerodynamic sound pressure level. The suppression of the outflow of pressurized air through the downstream part of the slits enhances the aerodynamic performance at low flow rates. Also, the predicted surface streamline at the design flow rate shows that air flows along the blade tip for the fan with slits, whereas the flow toward the blade tip appears for the fan without slits. As a result, the pressure distributions on the blade and the torque exerted on the fan blade are affected by the opening ratio of slits.


Author(s):  
Romain Prunières ◽  
Neo Imai ◽  
Yasuhiro Inoue ◽  
Takashi Okihara ◽  
Takahide Nagahara

Centrifugal pumps curve instability, characterized by a local dent and uprising head curve, often causes severe problems such as vibrations and noises. At low flow rates, stability of performance curve is necessary for reliable operation of the pump. Most of the studies regarding centrifugal pumps curves instability focus on flow rate around 60 % of the best efficiency flow rate. The purpose of present investigation is to analyse the causes of the occurrence of performance curve instability by means of Computational Fluid Dynamics (CFD) and to understand the mechanism of such instability at flow rates around 30 % of best efficiency flow rate. In order to understand the causes of the performance curve instability, two impellers with different outlet shape are analysed. During experimental tests, performance curve instability appeared around 30 % of the best efficiency flow rate on the first impeller while the second impeller remains stable. CFD analysis also shows unstable performance curve for the first impeller, and stable for the second one. Hence, a detailed analysis of the flow field of the two impellers and a quantitative comparison are performed in order to characterize the instability phenomenon.


1991 ◽  
Author(s):  
Ronald D. Flack ◽  
Steven M. Miner ◽  
Ronald J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two directional laser velocimeter. Data presented includes radial, tangential, and cross product Reynolds stresses. Blade to blade profiles were measured at four circumferential positions and four radii within and one radius outside the four bladed impeller. The pump was tested in two configurations; with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40% to 106% of the design flow rate. Variation in profiles among the individual passages in the orbiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9% and exit turbulence intensities were 6%. For 40% flow capacity the values increased to 18% and 19%, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


2019 ◽  
Vol 21 (27) ◽  
pp. 14605-14611 ◽  
Author(s):  
R. Moosavi ◽  
A. Kumar ◽  
A. De Wit ◽  
M. Schröter

At low flow rates, the precipitate forming at the miscible interface between two reactive solutions guides the evolution of the flow field.


1992 ◽  
Vol 114 (2) ◽  
pp. 350-358 ◽  
Author(s):  
R. D. Flack ◽  
S. M. Miner ◽  
R. J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two-directional laser velocimeter. Data presented include radial, tangential, and cross product Reynolds stresses. Blade-to-blade profiles were measured at four circumferential positions and four radii within and one radius outside the four-bladed impeller. The pump was tested in two configurations: with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40 to 106 percent of the design flow rate. Variation in profiles among the individual passages in the oribiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near-design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9 percent and exit turbulence intensities were 6 percent. For 40 percent flow capacity the values increased to 18 and 19 percent, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


Author(s):  
Fang-Ping Tang ◽  
Chao Liu ◽  
Ji-Ren Zhou ◽  
Hua Yang ◽  
Li Cheng

In this study, an axial flow pump impeller without guide vanes is experimentally investigated. The impeller used in the experiments consists of four blades. The particle image velocimetry technique and a five-hole probe have been used. Measurements of flow velocities in the outer part of the impeller have been made. PIV measurements have been realized in 12 meridian planes between blade-to-blade for design and off-design operating conditions. The meridian velocity is obtained with phase averaged method and the total circumferential mean velocity is obtained with an arithmetical average over the 12 circumferential data. The calculation is based on the CFX-TASC flow CFD code solving the three-dimensional Reynolds-averaged Navier-Stokes equation with RNG k–ε model of turbulence. The paper focuses on the comparisons of the results. Difference for the flow field between numerical and experimental results is small at large and design flow rate, while big difference occurs at small flow rate. It indicates that the numerical model is not suitable for separation flow.


Author(s):  
Azzam S. Salman ◽  
Jamil A. Khan

An experimental study was conducted in a closed loop spray cooling system working with deionized water as a cooling medium, to investigate the effects of surface modification on the spray cooling heat transfer enhancement in the single-phase region. Plain copper surface with diameter 1.5 cm and an enhanced surface with circular grooves were tested under different operating conditions. The volumetric flow rate of the coolant ranged from 115 mL/min to 177 mL/min., and the water inlet temperature was kept between 21–23 °C. Also, the distances between the nozzle and the target surface were varied at 8, 10, and 12 mm respectively. The results show that the distance between the nozzle and the target surface did not have a significant effect on the heat transfer performance for the low flow rates, while it has a slight effect on high flow rates for both surfaces. Also, increasing the liquid volumetric flow rate increases the amount of heat removed, and the heat transfer coefficient for both surfaces. Moreover, the maximum enhancement ratios achieved were 23.4% and 31% with volumetric flow rates of 153 mL/min, and 177 mL/min respectively.


2015 ◽  
Vol 137 (6) ◽  
Author(s):  
Qiaorui Si ◽  
Patrick Dupont ◽  
Annie-Claude Bayeul-Lainé ◽  
Antoine Dazin ◽  
Olivier Roussette ◽  
...  

Measurements are processed on a centrifugal pump model, which works with air and performs with the vane-island type diffuser of a real hydraulic pump, under five flow rates to investigate the internal flow characteristics and their influence on overall pump performance. The mean flow characteristics inside the diffuser are determined by using a miniature three-hole probe connected to an online data acquisition system. The flow structure at the inlet section of the diffuser is analyzed in detail, with a focus on the local pressure loss inside the vaneless gap and incidence angle distributions along the hub-to-shroud direction of the diffuser. Some existing calculations, including leakage effects, are used to evaluate the pressure recovery downstream of the impeller. Furthermore, particle image velocimetry (PIV) measurement results are obtained to help analyze the flow characteristics inside the vane-island diffuser. Each PIV measuring plane is related to one particular diffuser blade-to-blade channel and is analyzed by using the time-averaged method according to seven different relative positions of the impeller. Measurement results show that main loss is produced inside the vaneless part of the diffuser at low flow rates, which might have been caused by the strong rotor–stator interaction. When the impeller flow rate is greater than the diffuser design flow rate, a large fluctuating separated region occurs after the throat of the diffuser on the pressure side. Mean loss originates from the unsteady pressure downstream of the diffuser throat. For better characterization of the separations observed in previous experimental studies, complementary unsteady static pressure measurement campaigns have been conducted on the diffuser blade wall. The unsteadiness revealed by these measurements, as well as theirs effects on the diffuser performance, was then studied.


2011 ◽  
Vol 133 (10) ◽  
Author(s):  
Zhifeng Yao ◽  
Fujun Wang ◽  
Lixia Qu ◽  
Ruofu Xiao ◽  
Chenglian He ◽  
...  

Pressure fluctuation is the primary reason for unstable operations of double-suction centrifugal pumps. By using flush mounted pressure transducers in the semispiral suction chamber and the volute casing of a double-suction pump, the pressure fluctuation signals were obtained and recorded at various operating conditions. Spectral analyses were performed on the pressure fluctuation signals in both frequency domain and time-frequency domain based on fast Fourier transform (FFT) and an adaptive optimal-kernel time-frequency representation (AOK TFR). The results show that pressure fluctuations at the impeller rotating frequency and some lower frequencies dominated in the semispiral suction chamber. Pressure fluctuations at the blade passing frequency, the impeller rotating frequency, and their harmonic frequencies were identified in the volute casing. The amplitude of pressure fluctuation at the blade passing frequency significantly increased when the flow rate deviated from the design flow rate. At 107% of the design flow rate, the amplitude increased more than 254% than that at the design flow rate. The time-frequency characteristics of these pressure fluctuations were affected greatly by both operating conditions and measurement locations. At partial flow rates the pulsation had a great irregularity and the amplitudes at the investigated frequencies were much larger than ones at the design flow rate. An asymmetrical pressure fluctuation structure in the volute casing was observed at all flow rates. The pulsation behavior at the blade passing frequency was the most prominent near the volute tongue zone, and the pressure waves propagated in both the radial and circumferential directions.


Sign in / Sign up

Export Citation Format

Share Document