Introduction of an Integrated Turbo-Electrical Machine

Author(s):  
Sebastian Schuster ◽  
Christian Kreischer ◽  
Dieter Brillert

Turbomachines are commonly designed for a high mass flow rate. However, because of new cycle concepts, turbomachines are also required to compress or expand at small mass flow rates. One example is the supercritical carbon dioxide Brayton cycle. The mass flow rate can be in the range of one kg/s at an almost high fluid density at the inlet to the compressor. This results in a small through flow area. In this paper, a turbomachine concept is presented that integrates the turbomachine parts into an electrical machine. Specifically, the turbomachine is located in the gap between the rotor and the stator of the electrical machine. In that way, a very compact design can be achieved. This paper aims to explain the basic concept. An aerodynamic design study is performed that demonstrates the important parameters for machine performance. Additionally, the design of the electrical machine is discussed based on a realistic application. Finally, conclusions for further development are drawn.

2021 ◽  
Author(s):  
Raghuvaran D. ◽  
Satvik Shenoy ◽  
Srinivas G

Abstract Axial flow fans (AFF) are extensively used in various industrial sectors, usually with flows of low resistance and high mass flow rates. The blades, the hub and the shroud are the three major parts of an AFF. Various kinds of optimisation can be implemented to improve the performance of an AFF. The most common type is found to be geometric optimisation including variation in number of blades, modification in hub and shroud radius, change in angle of attack and blade twist, etc. After validation of simulation model and carrying out a grid independence test, parametric analysis was done on an 11-bladed AFF with a shroud of uniform radius using ANSYS Fluent. The rotational speed of the fan and the velocity at fan inlet were the primary variables of the study. The variation in outlet mass flow rate and total pressure was studied for both compressible and incompressible ambient flows. Relation of mass flow rate and total pressure with inlet velocity is observed to be linear and exponential respectively. On the other hand, mass flow rate and total pressure have nearly linear relationship with rotational speed. A comparison of several different axial flow tracks with the baseline case fills one of the research gaps.


Author(s):  
K. V. L. Narayana Rao ◽  
N. Ravi Kumar ◽  
G. Ramesha ◽  
M. Devathathan

Can type combustors are robust, with ease of design, manufacturing and testing. They are extensively used in industrial gas turbines and aero engines. This paper is mainly based on the work carried out in designing and testing a can type combustion chamber which is operated using JET-A1 fuel. Based on the design requirements, the combustor is designed, fabricated and tested. The experimental results are analysed and compared with the design requirements. The basic dimensions of the combustor, like casing diameter, liner diameter, liner length and liner hole distribution are estimated through a proprietary developed code. An axial flow air swirler with 8 vanes and vane angle of 45 degree is designed to create a re-circulation zone for stabilizing the flame. The Monarch 4.0 GPH fuel nozzle with a cone angle of 80 degree is used. The igniter used is a high energy igniter with ignition energy of 2J and 60 sparks per minute. The combustor is modelled, meshed and analysed using the commercially available ansys-cfx code. The geometry of the combustor is modified iteratively based on the CFD results to meet the design requirements such as pressure loss and pattern factor. The combustor is fabricated using Ni-75 sheet of 1 mm thickness. A small combustor test facility is established. The combustor rig is tested for 50 Hours. The experimental results showed a blow-out phenomenon while the mass flow rate through the combustor is increased beyond a limit. Further through CFD analysis one of the cause for early blow out is identified to be a high mass flow rate through the swirler. The swirler area is partially blocked and many configurations are analysed. The optimum configuration is selected based on the flame position in the primary zone. The change in swirler area is implemented in the test model and further testing is carried out. The experimental results showed that the blow-out limit of the combustor is increased to a good extent. Hence the effect of swirler flow rate on recirculation zone length and flame blow out is also studied and presented. The experimental results showed that the pressure loss and pattern factor are in agreement with the design requirements.


Micromachines ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 758
Author(s):  
Zhi-xin Gao ◽  
Ping Liu ◽  
Yang Yue ◽  
Jun-ye Li ◽  
Hui Wu

Although check valves have attracted a lot of attention, work has rarely been completed done when there is a compressible working fluid. In this paper, the swing check valve and the tilting check valve flowing high-temperature compressible water vapor are compared. The maximum Mach number under small valve openings, the dynamic opening time, and the hydrodynamic moment acting on the valve disc are chosen to evaluate the difference between the two types of check valves. Results show that the maximum Mach number increases with the decrease in the valve opening and the increase in the mass flow rate, and the Mach number and the pressure difference in the tilting check valve are higher. In the swing check valve, the hydrodynamic moment is higher and the valve opening time is shorter. Furthermore, the valve disc is more stable for the swing check valve, and there is a periodical oscillation of the valve disc in the tilting check valve under a small mass flow rate.


2003 ◽  
Vol 125 (3) ◽  
pp. 586-589 ◽  
Author(s):  
H.-P. Cheng ◽  
C.-J. Chen , ◽  
P.-W. Cheng ,

The CFD performance estimation of turbo booster vacuum pump shows the axial vortex and back flow is evident when the mass flow rate is increased. The pressure is increased from the pump inlet to the outlet for the low mass flow rate cases. But for high mass flow rate cases, the pressure is increased until the region near the end of the rotor then decreased. The calculated inlet pressure, compression ratio, and pumping speed is increased, decreased, and decreased, respectively, when the mass flow rate is increased. The pumping speed is increased when the rotor speed is increased.


Author(s):  
Lv Yufeng ◽  
Chen Yuzhou ◽  
Zhang Dongxu ◽  
Zhao Minfu ◽  
Duan Minghui

The test data of 64 rod bundles reflood heat transfer experiment performed by China Institute of Atomic Energy are analyzed. The heater rods are electrically powered and have a diameter of 9.5 mm and a length of 4.3 m arranged in a 8 × 8 array with a 12.6 mm pitch. The test parameter is in the range of 10–500 kg/(m2 · s) for injection water mass flux, 20–80°C for injection water temperature, 500–600°C for initial heater rod temperature, 0–1.1 kW/m for heating power, respectively. The system pressure is atmosphere pressure. Two kinds of spacer grids with and without mixing vanes are adopted to investigate their effect on heat transfer. The result shows that rod wall temperature downstream the spacer grid with mixing vanes is lower than that without mixing vanes, which indicates that the heat transfer is enhanced with mixing vanes. The rewetting velocity is nearly a constant under a certain test condition. The experimental values of rewetting velocity are compared with heat conduction controlled theories. At low mass flow rate, one-dimensional conduction gives agreement with experiment; while at high mass flow rate, the two-dimensional conduction theory is shown to be in agreement with experiment data. The RELAP5/ MOD3.3 reflood model is assessed against the test data. Comparison of code prediction and measured data indicates that the code predicts quench time relatively well but the peak rod temperature differs.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


Author(s):  
Timothe´e Ewart ◽  
Irina A. Graour ◽  
Pierre Perrier ◽  
J. Gilbert Me´olans

An experimental investigation in a single silica microtube in isothermal stationary flow for various gases is made from the hydrodynamic to the near free molecular regime to study the reflection/accommodation process at the wall. This kind of investigation requires, more than other Micro-Electro-Mechanical-Systems (MEMS) experiments, a powerful experimental platform to measure very small mass flow rate. A global analytic expression, based on the Navier-Stokes (NS) equations with second order boundary conditions, is used to yield the Tangential Momentum Accommodation Coefficient (TMAC) in 0.003–0.3 Knudsen number range. Otherwise, the experimental results of the mass flow rate is compared with theoretical values calculated from kinetic approaches using variable TMAC as fitting parameter over the 0.3–30 Knudsen number range. Finally, whatever the theoretical approach the TMAC values obtained from the different gas-surface pairs are rather close one to other, but the TMAC values seem decreasing when the molecular mass increases.


2021 ◽  
Vol 6 ◽  
Author(s):  
Panagiotis Grigoriadis ◽  
Alexander Hoffmann ◽  
Chi Binh La

A diverse set of technology solutions are in development for reducing vehicular CO2 emissions. Beside the conventional internal combustion engine, there are hybrid powertrains, fuel cells and full electric vehicles. The challenge is finding the right technology that can be quickly implemented into production as a cost effective solution. In addition to CO2 reduction during vehicle operation, the impact of CO2 in the production and recycling of future vehicles must also be considered. From this perspective, the role of turbocharging is evolving, becoming more important for the future. It is an enabler for mature technologies known to improve engine efficiency like Miller timing, lean burn, increased exhaust gas recirculation (EGR) dilution and exhaust heat recovery. As a boosting device, improved turbocharging can also benefit other powertrain types like fuel cells. All previously mentioned applications benefit from wider compressor maps and higher compressor ratios. To achieve an extension of the performance map to areas of low mass flow rate, different methods have been discussed with the two most promising being trim reduction introduced by IAV’s Variable Trim Compressor (VTC) and swirl generation. The most common device for inducing a swirl onto the incoming airflow is to use swirl generating wings in front of the compressor wheel. However, Iwakiri explained that putting a single plate in front of the compressor wheel disturbs the recirculating flow, which acts positively to extend the compressor map. On this basis, plates were developed that guide the strongly swirled back flowing air in such a way that they impose a swirl on the incoming air. Trim reduction is well known for its ability to shift the surge line and maintain compressor efficiency. To achieve this, a conical element before the compressor wheel guides the incoming flow to the inner area of the wheel resulting in reduced flow separation. An orifice can also achieve almost the same effect but with much less axial extension. The advantages and disadvantages of these measures are explained using numerical (CFD) and experimental (turbocharger test bench) to show the potential of each approach. In summary trim reduction using a conical geometry is still the best performing approach. However, considering package restrictions, an orifice is also a good choice. Whereas swirl producing principles have a moderate impact on shifting the surge line. The extension of high mass flow rate is also of interest and this study shows a simple method to improve the compressor performance map in this area. A combination of the measures to expand the map in both directions is conceivable and is presented here as a concept.


2019 ◽  
Vol 141 (12) ◽  
Author(s):  
Deb Banerjee ◽  
Rick Dehner ◽  
Ahmet Selamet ◽  
Kevin Tallio ◽  
Keith Miazgowicz ◽  
...  

Abstract The flow field at the inlet of a turbocharger compressor has been studied through stereoscopic particle image velocimetry (SPIV) experiments under different operating conditions. It is found that the flow field is quite uniform at high mass flow rates; but as the mass flow rate is reduced, flow reversal from the impeller is observed as an annular ring at the periphery of the inlet duct. The inception of flow reversal is observed to occur in the mid-flow operating region, near peak efficiency, and corresponds to an incidence angle of about 15.5 deg at the inducer blade tips at all tested speeds. This reversed flow region is marked with high tangential velocity and rapid fluctuations. It grows in strength with reducing mass flow rate and imparts some of its angular momentum to the forward flow due to mixing. The penetration depth of the reversed flow upstream from the inducer plane is found to increase quadratically with decreasing flow rate.