Improving Liquid Supply Pathways on Graphene Oxide Coated Surfaces for Enhanced Pool Boiling Heat Transfer Performance

Author(s):  
Aniket M. Rishi ◽  
Anju Gupta ◽  
Satish G. Kandlikar

Graphene is a two-dimensional material that possesses excellent thermal properties and thus has gained an enormous attention in the applications of heat transfer. In this work, we demonstrate the enhancement of boiling heat transfer performance on substrate coated with graphene oxide and/or copper composites. The graphene oxide and/or copper composites were introduced on the substrate by two commonly used coating techniques-dip-coating and a two-step electrochemical deposition method. The focus of this paper is to compare the morphologies, surface properties such as wickability and porosity rendered by these coating methods and compare the resultant heat transfer coefficients and critical heat fluxes. The surfaces were characterized by Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), and Fourier Transform Infrared (FTIR) techniques. Critical Heat Flux of 220 W/cm2 at the wall superheat of 14.8°C was achieved for the highest 2.5% GO-Cu electrodeposited chip, while CHF of 128 W/cm2 at the wall superheat of 13.2°C was achieved for the 5 minutes dip coated test surface.

2021 ◽  
Vol 7 ◽  
Author(s):  
Akam Aboubakri ◽  
Vahid Ebrahimpour Ahmadi ◽  
Suleyman Celik ◽  
Abdolali K. Sadaghiani ◽  
Khellil Sefiane ◽  
...  

Flow boiling is one of the most effective mechanisms in heat transfer thanks to the latent heat of vaporization. Surface modifications such as mixed-wettability have a considerable effect on the boiling heat transfer performance in terms of enhancement in boiling heat transfer as well as critical heat flux. This study introduces a new method of fabrication of biphilic surfaces, where C4F8 (Octafluorocyclobutane) islands are surrounded by silicon. Two different biphilic surfaces were fabricated and compared with the entirely uniform hydrophobic surface taken as a reference,. Each of the biphilic surfaces has three different sections, namely inlet, middle and outlet regions. The first region is mainly hydrophobic (inlet), while the third region is mainly hydrophilic (outlet). The heat transfer coefficients were obtained at different heat fluxes. Compared to the entirely uniform hydrophobic surface, the results show that biphilic surfaces enhance the boiling heat transfer performance by up to 50%. The visualization results revealed that the biphilic surfaces lead to more nucleation sites in the bubbly flow regime and break up the elongated bubbles in the slug flow regime.


Author(s):  
Gregory J. Michna ◽  
Eric A. Browne ◽  
Yoav Peles ◽  
Michael K. Jensen

Electronics cooling is becoming increasingly difficult due to increasing power consumption and decreasing size of processor chips. Heat fluxes in processors and power electronics are quickly approaching levels that cannot be easily addressed by forced air convection over finned heat sinks. Jet impingement cooling offers high heat transfer coefficients and has been used effectively in conventional-scale applications such as turbine blade cooling and the quenching of metals. However, literature in the area of microjet arrays is scarce and has not studied arrays of large area ratios. Hence, the objective of this study is to experimentally assess the heat transfer performance of arrays of microjets. The microjet arrays were fabricated using MEMS processes in a clean room environment. The heat transfer performance of several arrays using deionized water as the working fluid was investigated. Inline and staggered array arrangements were investigated, and the area ratio (total area of the jets divided by the surface area) was varied between 0.036 and 0.35. Reynolds numbers defined by the jet diameter were in the range of 50 to 3,500. Heat fluxes greater than 1,000 W/cm2 were obtained at fluid inlet-to-surface temperature differences of less than 30 °C. Heat transfer performance improved as the area ratio was increased.


2019 ◽  
Vol 9 (14) ◽  
pp. 2818 ◽  
Author(s):  
Shouguang Yao ◽  
Zecheng Teng

At present, there are many applications of nanofluids whose research results are fruitful. Nanofluids can enhance the critical heat flux, but the effect on boiling heat transfer performance still has disagreement. Base liquids with higher viscosity improve the boiling heat transfer performance of nanofluids. When the base liquid is a multicomponent solution, the relative movement between the different solutions enhances the microscopic movement of the nanoparticles due to the different evaporation order during the boiling process, so that the boiling heat transfer performance is enhanced. Compared with the thermal conductivity of the heated surface, the deposition of the low thermal conductivity nanoparticles reduces the heat dissipation rate of the heated surface and improves the wall superheat. Then the enhancement of the boiling heat transfer coefficient should be attributed to the thermal conductivity improvement of base fluid and the bubble disturbance resulted from the nanoparticle’s microscopic motion.


2010 ◽  
Vol 37 (1) ◽  
pp. 115-120 ◽  
Author(s):  
王亚青 Wang Yaqing ◽  
刘明侯 Liu Minghou ◽  
刘东 Liu Dong ◽  
徐侃 Xu Kan ◽  
何国梁 He Guoliang

Author(s):  
Vishal V. Nirgude ◽  
Mayank Modak ◽  
Avadhesh K. Sharma ◽  
Santosh K. Sahu

In the present experimental study an attempt has been made to study the boiling heat transfer characteristics of variety of enhanced surfaces. Three different copper test surfaces: polished copper and two structured surfaces were used in the present investigation. The heat transfer performance of each surface is studied under saturated pool boiling conditions at atmospheric pressure by using water and isopropyl as pool liquid. The effect of intersecting tunnel geometry with 0.5 mm and 1 mm depth on heat transfer performance has been studied. The comparison of heat transfer coefficient indicates that the intersecting tunnel structure enhanced the boiling heat transfer performance and reduced the wall superheat at given heat flux inputs.


NANO ◽  
2019 ◽  
Vol 14 (10) ◽  
pp. 1950124
Author(s):  
Hao Zhang ◽  
Zeng-en Li ◽  
Shan Qing ◽  
Zhuangzhuang Jia ◽  
Jiarui Xu ◽  
...  

Nucleate pool boiling heat transfer experiments have been conducted to nanofluids on a horizontal cylinder tube under atmospheric pressure. The nanofluids are prepared by dispersing Al2O3 nanoparticles into distilled water at concentrations of 0.001, 0.01, 0.1, 1 and 2[Formula: see text]wt.% with or without sodium, 4-dodecylbenzenesulfonate (SDBS). The experimental results showed that: nanofluids at lower concentrations (0.001[Formula: see text]wt.% to 1[Formula: see text]wt.%) can obviously enhance the pool boiling heat transfer performance, but signs of deterioration can be observed at higher concentration (2[Formula: see text]wt.%). The presence of SDBS can obviously enhance the pool boiling heat transfer performance, and with the presence of SDBS, a maximum enhancement ratio of BHTC of 69.88%, and a maximum decrease ratio of super heat of 41.12% can be found in Group NS5 and NS4, respectively. The tube diameter and wall thickness of heating surface are the influential factors for boiling heat transfer coefficient. Besides, we find that Rohsenow formula failed to predict the characteristics of nanofluids. The mechanism study shows that: the decrease of surface tension, which leads to the decrease of bubble departure diameter, and the presence of agglomerates in nanofluids are the reasons for the enhanced pool boiling heat transfer performance. At higher concentration, particle deposition will lead to the decrease of distribution density of the vaporization core, and as a result of that, the boiling heat transfer performance will deteriorate.


Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


Sign in / Sign up

Export Citation Format

Share Document