Research on remote stress test system of lifting machinery metal structure

2013 ◽  
Author(s):  
Zhifen Tang
2010 ◽  
pp. 61-81 ◽  
Author(s):  
O. Solntsev ◽  
A. Pestova ◽  
M. Mamonov

The article analyzes factors that affect growth of the share of non-performing loans in the loan portfolio of Russian banks and proposes approaches for this share forecasting on the basis of dynamics of macroeconomic indicators. It also deals with methodological issues of remote stress-test of lending agencies. Using the results of conducted stress-test of Russian banks the authors assess their perspective capital needs in 2010 and estimate the share of government assistance in capital injections. Furthermore, the authors define the scale of vulnerable banks groups in the Russian banking sector.


1983 ◽  
Vol 55 (4) ◽  
pp. 1178-1186 ◽  
Author(s):  
M. P. Yeh ◽  
R. M. Gardner ◽  
T. D. Adams ◽  
F. G. Yanowitz ◽  
R. O. Crapo

Despite the popularity of the concept of “anaerobic threshold” (AT), the noninvasive detection criteria remain subjective, and invasive validations of AT have been based on lactate data of arterial, mixed venous, venous, and capillary blood samples without any concern for the possible lactate differences from these sources. Eight normal subjects underwent two exercise tests on a bicycle ergometer. The protocol consisted of 3 min of rest, 3 min of 0 work load, and a 20 W/min ramp (1 W/3 s) until exhaustion. Simultaneous arterial and venous blood samples were drawn during the second test. Noninvasive gas response data were measured using a computerized breath-by-breath stress test system. Threshold phenomenon of the lactate accumulation was not found. The arterial lactate levels increased continuously after the start of the exercise ramp. The rise in venous lactate lagged behind the rise of the arterial lactate by about 1.5 min, and therefore venous lactate was not considered suitable for AT detection. Four independent exercise physiologists determined AT from the gas response data. The reviewer variability (avg range 16%) of AT for a given subject was representative of AT values reported for untrained and trained individuals (40-70% maximum O2 consumption). We concluded that 1) AT is not detectable using invasive methods (arterial and venous lactates); and 2) the noninvasive gas response determination has such a large range of reviewer variability that it is unsuitable for clinical use.


2020 ◽  
Vol 2020 (1) ◽  
pp. 000078-000084
Author(s):  
Hao Zhuang ◽  
Robert Bauer ◽  
Markus Dinkel

Abstract In the power semiconductor industry, there is continuous development towards higher maximum current capability of devices while device dimensions shrink. This leads to an increase in current density which the devices have to handle, and raises the question if electromigration (EM) is a critical issue here. Generally, an EM failure can be described by the Black’s equation with temperature and current density as the main influencing factors. Normally, the current that the power packages need to handle lies in the range of 100 A. However, it should be noted that power devices exhibit asymmetric sizes of drain and source contacts. This may lead to higher current density at the source leads (area ratio drain/source: ~8x for QFN 5×6). Nevertheless, the source lead area is still much larger than that of the flip chip bumps (i.e., 28 times larger compared to a 100 μm micro-bump). This typically enhances the safety of the power device with respect to EM. However, with regard to future development towards higher maximum current capability, we intended to investigate further on the EM of power devices. In the present work, we focused on the PQFN 5×6 package to study the EM behavior of a power device soldered on a Printed Circuit Board (PCB). We employed the highest current (120 A) and temperature (150 °C) that the stress test system could handle to study EM in accelerated mode. First fails occurred after ~1200 h, which was much earlier than expected from previous flip-chip investigations. In addition, we found separation gaps in the solder joint between drain contact and PCB, which experienced the lowest current density in the whole test. Contradictorily, we observed only minor solder degradation at the source interface, regardless of the higher current density there. Nevertheless, the separating metal interfaces still correlated well with the current direction. Thermal simulations revealed that due to the self-heating of the device by the high current applied, both the drain and source leads were exposed to much higher temperatures (Tmax = 168 °C) than the PCB board which was kept under temperature control at 150 °C. This temperature difference resulted in a thermal gradient between the device and PCB which, in turn, triggered thermal migration (TM) in addition to EM. As TM for the drain contact occurred in the same direction as EM, it enhanced the degradation effect and therefore led to a shorter time-to-failure at the drain. In contrast to this, such an enhanced effect did not occur at the source side. As a result, we observed higher solder degradation at the drain side, which we did confirm by switching the current direction in the test. To minimize the TM effect, a special EM test vehicle, which used a Cu plate instead of the MOSFET chip, was designed and fabricated. Thermal simulation verified that the device operated at similar temperatures as the PCB board. Using this setup, it was possible to study EM in an accelerated mode and, thus, investigate the pure EM behavior of the power device.


2012 ◽  
Vol 166-169 ◽  
pp. 1091-1096
Author(s):  
Jianpeng Sun ◽  
Chao Fu Zhu ◽  
Jin Long Zhao

By using the key technology of wireless sensor networks, a stress test system was designed, which takes the M2110 wireless sensor networks as a platform. Based on the hardware design and software design of TinyOS2.0 sensor nodes and gateway nodes, the signal transmission performance of wireless sensor networks for the stress test system was tested and researched. In the visual conditions, the maximum communication distance of M2110 wireless node is up to 601 meters. In the non-visual conditions, M2110 wireless node also has a certain signal transmission capacity. On the situation of multi-hop nodes network, the success rate of data transfer has relation to the transmission rate of data packet and the number of hops for nodes.


2016 ◽  
Vol 2016 (0) ◽  
pp. J2210102
Author(s):  
Kohei FUJIMURA ◽  
Naoki HAYAKAWA ◽  
Kensuke TSUCHIYA ◽  
Toshifumi KAKIUCHI ◽  
Yoshihiko UEMATSU

1984 ◽  
Vol 11 (4) ◽  
pp. 347-351
Author(s):  
MASANORI EGUCHI
Keyword(s):  

2021 ◽  
Vol 257 ◽  
pp. 03071
Author(s):  
Jun Qiu ◽  
Zheng-qiu Huang ◽  
Li-xin Ren ◽  
Yao-ting Tong

Due to the long service life of a quayside container crane in an enterprise, there is slight corrosion on the surface of metal structure, which has potential safety hazard. In order to master the technical condition of the metal structure of the crane, the stress distribution and change information of the crane are obtained by dynamic and static stress testing and non-destructive testing. According to the analysis and test results, the safety assessment of the whole machine is completed and reasonable management suggestions are put forward.


Sign in / Sign up

Export Citation Format

Share Document