The process development of laser surface modification of commercially pure titanium (Grade 2) with rhenium

2016 ◽  
Author(s):  
K. Kobiela ◽  
I. Smolina ◽  
R. Dziedzic ◽  
P. Szymczyk ◽  
T. Kurzynowski ◽  
...  
Alloy Digest ◽  
2020 ◽  
Vol 69 (6) ◽  

Abstract UPM CP Titanium Grade 3 (UNS R50550) is an unalloyed commercially pure titanium that exhibits moderate strength (higher strength than that of Titanium Grade 2), along with excellent formability and corrosion resistance. It offers the highest ASME allowable design stress of any commercially pure grade of titanium, and can be used in continuous service up to 425 °C (800 °F) and in intermittent service up to 540 °C (1000 °F). This datasheet provides information on composition, physical properties, and elasticity. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: Ti-167. Producer or source: United Performance Metals.


Author(s):  
Karibeeran Shanmuga Sundaram ◽  
Gurusami Kiliyappan ◽  
Senthil Kumaran Selvadurai

Laser shock peening (LSP) is one of the innovative technique that produces a compressive residual stress on the surface of metallic materials, thereby significantly increasing its fatigue life in applications where failure is caused by surface-initiated cracks. The specimens were treated with laser shock waves with different processing parameters, and characterization studies were made on treated specimens. The purpose of the present study was to investigate the influence of Nd:YAG laser on commercially pure titanium (CP-Ti) used in prosthetic dental restorations. The treatment influenced change in microstructure, micro hardness, surface roughness, and wear resistance characteristics. Though CP-Ti is considered as an excellent material for dental applications due to its outstanding biocompatibility, it is not suitable when high mastication forces are applied. In the present study, pulsed Nd:YAG laser surface treatment technique was adopted to improve the wear resistance of CP-Ti. The wear test pin specimens of CP-Ti were investment cast with centrifugal titanium casting machine. The wear properties of specimens were evaluated after LSP on a “pin-on-disc” wear testing tribometer, as per ASTM G99-05 standards. The results of the wear experiment showed that the treated laser surface has higher wear resistance, micro hardness, and surface roughness compared to as-cast samples. The improvement of wear resistance may be attributed due to grain refinement imparted by LSP processes. The microstructure, wear surfaces, wear debris, and morphology of the specimen were analyzed by using optical electron microscope, scanning electron microscope, and X-ray diffraction (XRD). The data were compared using ANOVA and post-hoc Tukey tests. The characteristic change resulted in increase in wear resistance and decrease in wear rate. Hence, it is evident that the more reliable and removable partial denture metal frameworks for dental prostheses may find its applications.


2015 ◽  
Vol 60 (3) ◽  
pp. 1895-1900 ◽  
Author(s):  
K. Dyja ◽  
W. Więckowski

Abstract An important factor in the possibility of obtaining correct drawn parts with the desired functional properties is the friction between the stamped sheet and the tool. The article discusses the impact of technological lubricants developed according to our own formulas, based on vegetable oils, on the stamping process taking into account the strain distributions in the drawn parts. Biodegradable lubricants based on rapeseed oil with an addition of stearic acid or boric acid were used. The results of the friction coefficient in a strip drawing test and the numerical analysis results of the stamping process of a spherical cap from sheet metal: aluminium 2024, commercially pure titanium Grade 2, steel 5604 in dry friction and lubrication conditions, are presented. Strain distributions and changes in the drawn part wall thickness were analysed.


Author(s):  
Gry Hulsart-Billström ◽  
Oscar Janson ◽  
Håkan Engqvist ◽  
Ken Welch ◽  
Jaan Hong

Abstract The release of growth factors from platelets, mediated by the coagulation and the complement system, plays an important role in the bone formation around implants. This study aimed at exploring the thromboinflammatory response of H2O2-alkali soaked commercially pure titanium grade 2 discs exposed to whole human blood, as a way to assess the bioactivity of the discs. Commercially pure titanium grade 2 discs were modified by soaking in H2O2, NaOH and Ca(OH)2. The platelet aggregation, coagulation activation and complement activation was assessed by exposing the discs to fresh whole blood from human donors. The platelet aggregation was examined by a cell counter and the coagulation and complement activation were assessed by ELISA-measurements of the concentration of thrombin-antithrombin complex, C3a and terminal complement complex. The modified surface showed a statistically significant increased platelet aggregation, coagulation activation and complement activation compared to unexposed blood. The surface also showed a statistically significant increase of coagulation activation compared to PVC. The results of this study showed that the H2O2-alkali soaked surfaces induced a thromboinflammatory response that indicates that the surfaces are bioactive.


2017 ◽  
Vol 1 (88) ◽  
pp. 5-11 ◽  
Author(s):  
J. Palán ◽  
L. Maleček ◽  
J. Hodek ◽  
M. Zemko ◽  
J. Dzugan

Purpose: At present, materials research in the area of SPD (severe plastic deformation) processes is very intensive. Materials processed by these techniques show better mechanical properties and have finer grain when compared to the input feedstock. The refined microstructure may be ultrafine-grained or nanostructured, where the grain size becomes less than 100 nm. One of the materials used for such processes is CP (commercially pure) titanium of various grades, which is widely used for manufacturing dental implants. The article deals with one of the technologies available for the production of ultrafine-grained titanium: Conform technology. CP titanium processed by CONFORM technology exhibits improved mechanical properties and very favourable biocompatibility, due to its fine-grained structure. The article presents the current experience in the production of ultrafine CP titanium using this technology. The main objective of this article is describing the behaviour of CP titanium during forming in the Conform device and its subsequent use in dental implantology. Design/methodology/approach: In the present study, commercially pure Grade 2 titanium was processed using the CONFORM machine. The numerical simulation of the process was done using FEM method with DEFORMTM software. The evaluation was performed by simple tensile testing and transmission electron microscopy. The first conclusions were derived from the determined mechanical properties and based on analogies in available publications on a similar topic. Findings: This study confirmed that the SPD process improves mechanical properties and does not impair the ductility of the material. The CONFORM process enables the continuous production of ultrafine-grained or nanostructured materials. Research limitations/implications: At the present work, the results show the possible way of continuous production of ultrafine-grained or nanostructured materials. Nevertheless, the further optimization is needed in order to improve the final quality of wires and stabilize the process. As these factors will be solved, the technology will be ready for the industry. Practical implications: The article gives the practical information about the continuous production of ultrafine-grained pure titanium Grade 2 and the possibility of use this material for dental implants. Originality/value: The present paper gives information about the influence of the CONFORM technology on final mechanical and structural properties with the emphasis on technological aspects


Sign in / Sign up

Export Citation Format

Share Document