An explorative study of an optimum spectral window in the near infrared to the mid-infrared region for Optical Coherence Tomography applicable to the non-invasive analysis of paintings

Author(s):  
Alessandra Vichi ◽  
Chi Shing Cheung ◽  
Haida Liang
Coatings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 877
Author(s):  
Christian R. Petersen ◽  
Narayanan Rajagopalan ◽  
Christos Markos ◽  
Niels M. Israelsen ◽  
Peter J. Rodrigo ◽  
...  

Near- and mid-infrared optical coherence tomography (OCT) is evaluated as a non-destructive and non-contact reflection imaging modality for inspection of industrial and marine coatings. Near-infrared OCT was used to obtain high-resolution images (~6/2 µm lateral/axial) of hidden subsurface cracks and defects in a resin base coating, which had been exposed to high pressure and high temperature to study coating degradation in hostile environments. Mid-infrared OCT was employed for high-resolution (~15/8.5 µm lateral/axial) subsurface inspection of highly scattering marine coatings, demonstrating monitoring of wet film thickness and particle dispersion during curing of a 210 µm layer of antifouling coating, and detection of substrate corrosion through 369 µm of high-gloss alkyd enamel. Combining high-resolution and fast, non-invasive scanning, OCT is therefore considered a promising tool for studying coating performance and for industrial inspection.


Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06645
Author(s):  
Charlotte Theresa Trebing ◽  
Sinan Sen ◽  
Stefan Rues ◽  
Christopher Herpel ◽  
Maria Schöllhorn ◽  
...  

2021 ◽  
Vol 127 (4) ◽  
Author(s):  
S. Skruszewicz ◽  
S. Fuchs ◽  
J. J. Abel ◽  
J. Nathanael ◽  
J. Reinhard ◽  
...  

AbstractWe present an overview of recent results on optical coherence tomography with the use of extreme ultraviolet and soft X-ray radiation (XCT). XCT is a cross-sectional imaging method that has emerged as a derivative of optical coherence tomography (OCT). In contrast to OCT, which typically uses near-infrared light, XCT utilizes broad bandwidth extreme ultraviolet (XUV) and soft X-ray (SXR) radiation (Fuchs et al in Sci Rep 6:20658, 2016). As in OCT, XCT’s axial resolution only scales with the coherence length of the light source. Thus, an axial resolution down to the nanometer range can be achieved. This is an improvement of up to three orders of magnitude in comparison to OCT. XCT measures the reflected spectrum in a common-path interferometric setup to retrieve the axial structure of nanometer-sized samples. The technique has been demonstrated with broad bandwidth XUV/SXR radiation from synchrotron facilities and recently with compact laboratory-based laser-driven sources. Axial resolutions down to 2.2 nm have been achieved experimentally. XCT has potential applications in three-dimensional imaging of silicon-based semiconductors, lithography masks, and layered structures like XUV mirrors and solar cells.


2021 ◽  
Vol 137 ◽  
pp. 106861
Author(s):  
Deepa Joshi ◽  
Ankit Butola ◽  
Sheetal Raosaheb Kanade ◽  
Dilip K. Prasad ◽  
S.V. Amitha Mithra ◽  
...  

Pharmaceutics ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 217
Author(s):  
Maria Jesus Rodrigo ◽  
Amaya Pérez del Palomar ◽  
Alberto Montolío ◽  
Silvia Mendez-Martinez ◽  
Manuel Subias ◽  
...  

Intravitreal injection is the gold standard therapeutic option for posterior segment pathologies, and long-lasting release is necessary to avoid reinjections. There is no effective intravitreal treatment for glaucoma or other optic neuropathies in daily practice, nor is there a non-invasive method to monitor drug levels in the vitreous. Here we show that a glaucoma treatment combining a hypotensive and neuroprotective intravitreal formulation (IF) of brimonidine–Laponite (BRI/LAP) can be monitored non-invasively using vitreoretinal interface imaging captured with optical coherence tomography (OCT) over 24 weeks of follow-up. Qualitative and quantitative characterisation was achieved by analysing the changes in vitreous (VIT) signal intensity, expressed as a ratio of retinal pigment epithelium (RPE) intensity. Vitreous hyperreflective aggregates mixed in the vitreous and tended to settle on the retinal surface. Relative intensity and aggregate size progressively decreased over 24 weeks in treated rat eyes as the BRI/LAP IF degraded. VIT/RPE relative intensity and total aggregate area correlated with brimonidine levels measured in the eye. The OCT-derived VIT/RPE relative intensity may be a useful and objective marker for non-invasive monitoring of BRI/LAP IF.


1993 ◽  
Vol 1 (2) ◽  
pp. 99-108 ◽  
Author(s):  
P. Robert ◽  
M.F. Devaux ◽  
A. Qannari ◽  
M. Safar

Multivariate data treatments were applied to mid and near infrared spectra of glucose, fructose and sucrose solutions in order to specify near infrared frequencies that characterise each carbohydrate. As a first step, the mid and near infrared regions were separately studied by performing Principal Component Analyses. While glucose, fructose and sucrose could be clearly identified on the similarity maps derived from the mid infrared spectra, only the total sugar content of the solutions was observed when using the near infrared region. Characteristic wavelengths of the total sugar content were found at 2118, 2270 and 2324 nm. In a second step, the mid and near infrared regions were jointly studied by a Canonical Correlation Analysis. As the assignments of frequencies are generally well known in the mid infrared region, it should be useful to study the relationships between the two infrared regions. Thus, the canonical patterns obtained from the near infrared spectra revealed wavelengths that characterised each carbohydrate. The OH and CH combination bands were observed at: 2088 and 2332 nm for glucose, 2134 and 2252 nm for fructose, 2058 and 2278 nm for sucrose. Although a precise assignment of the near infrared bands to chemical groups within the molecules was not possible, the present work showed that near infrared spectra of carbohydrates presented specific features.


Sign in / Sign up

Export Citation Format

Share Document