scholarly journals The Validity of Consumer-Level Activity Monitors in Healthy Older Adults in Free-Living Conditions

2018 ◽  
Vol 26 (1) ◽  
pp. 128-135 ◽  
Author(s):  
Nicolas Farina ◽  
Ruth G. Lowry

Consumer-level activity monitors, such as Fitbit and Misfit devices, are a popular and low-cost means of measuring physical activity. This study aims to compare the accuracy of step counts from two consumer-level activity monitors against two reference devices in healthy, community-dwelling older adults in free-living conditions. Twenty-five older adults (aged 65–84) simultaneously wore 5 devices (e.g., Misfit Shine and Fitbit Charge HR) over 7 consecutive days. All consumer-level activity monitors positively correlated with reference devices (p < .001). There was also substantial to near perfect agreement between all consumer-level activity monitors and reference devices. Compared to the ActiGraph GT3X+, the waist-worn Misfit Shine displayed the highest agreement amongst the devices worn (ICC = 0.96, 95% 0.91 to 0.99). The wrist-worn devices showed poorer agreement to reference devices. Future research needs to consider that not all consumer-level activity monitors are equal in terms of accuracy, design, and function.

2021 ◽  
Author(s):  
Kaja Kastelic ◽  
Marina Dobnik ◽  
Stefan Loefler ◽  
Christian Hofer ◽  
Nejc Šarabon

BACKGROUND Wrist worn consumer-grade activity trackers are popular devices, developed mainly for personal use, but with the potential to be used also for clinical and research purposes. OBJECTIVE The objective of this study was to explore the validity, reliability and sensitivity to change of movement behaviours metrics from three popular activity trackers (POLAR Vantage M, Garmin Vivosport and Garmin Vivoactive 4s) in controlled and free-living conditions when worn by older adults. METHODS Participants (n = 28; 74 ± 5 years) underwent a videotaped laboratory protocol while wearing all three activity trackers. On a separate occasion, participants wore one (randomly assigned) activity tracker and a research grade physical activity monitor ActiGraph wGT3X-BT simultaneously for six consecutive days for comparisons. RESULTS Both Garmin activity trackers showed excellent performance for step counts, with mean absolute percentage error (MAPE) below 20 % and intraclass correlation coefficient (ICC2,1) above 0.90 (P < .05), while Polar Vantage M substantially over counted steps (MAPE = 84 % and ICC2,1 = 0.37 for free-living conditions). MAPE for sleep time was within 10 % for all the trackers tested, while far beyond 20 % for all the physical activity and calories burned outputs. Both Garmin trackers showed fair agreement (ICC2,1 = 0.58–0.55) for measuring calories burned when compared with ActiGraph. CONCLUSIONS Garmin Vivoactive 4s showed overall best performance, especially for measuring steps and sleep time in healthy older adults. Minimal detectible change was consistently lower for an average day measures than for a single day measure, but still relatively high. The results provided in this study could be used to guide choice on activity trackers aiming for different purposes – individual use/care, longitudinal monitoring or in clinical trial setting.


2015 ◽  
Vol 40 (5) ◽  
pp. 448-456 ◽  
Author(s):  
Hideaki Kumahara ◽  
Makoto Ayabe ◽  
Misato Ichibakase ◽  
Akari Tashima ◽  
Maiko Chiwata ◽  
...  

The purpose of this study was to examine the validity of counting steps and computing indices of moderate-to-vigorous physical activity (MVPA) using miniature activity monitors with 3-D technology worn at various locations under controlled (CON) and free-living conditions (FL). Kenz e-style2, Tanita Calorism Smart, and Omron Calori Scan HJA-306 activity monitors were assessed. Nine and 31 young adult women were assigned to the CON and FL studies, respectively. While walking or jogging on a treadmill at 5 different speeds, the subjects simultaneously carried the 3 different monitors in a pants pocket (PP), a chest shirt pocket, and a shoulder bag (B). Under the FL condition, the 3 monitors were placed only at the PP and B locations for practical reasons. Significant effects of monitor location and walking/jogging speed on the step count measured by the 3 monitors were evaluated under the CON condition. Monitors placed at both PP and B tended to underestimate the number of steps; however, there were no significant differences between the values obtained with the Kenz monitor and those obtained with a criterion accelerometer under the FL condition. Moreover, strong correlations were observed between steps measured by monitors placed at PP and steps measured by the criterion accelerometer. The amount of MVPA for the PP location and the non-carrying duration of the bag for the B location were considered to be important determinants of the accuracy of step counting under the FL condition. In conclusion, monitors placed at the PP location, especially the Kenz monitor, showed acceptable accuracy for young adult women in real-life settings. In contrast, MVPA indices assessed using these monitors showed limited validity.


2020 ◽  
Vol 3 (2) ◽  
pp. 100-109
Author(s):  
Christopher P. Connolly ◽  
Jordana Dahmen ◽  
Robert D. Catena ◽  
Nigel Campbell ◽  
Alexander H.K. Montoye

Purpose: We aimed to determine the step-count validity of commonly used physical activity monitors for pregnancy overground walking and during free-living conditions. Methods: Participants (n = 39, 12–38 weeks gestational age) completed six 100-step overground walking trials (three self-selected “normal pace”, three “brisk pace”) while wearing five physical activity monitors: Omron HJ-720 (OM), New Lifestyles 2000 (NL), Fitbit Flex (FF), ActiGraph Link (AG), and Modus StepWatch (SW). For each walking trial, monitor-recorded steps and criterion-measured steps were assessed. Participants also wore all activity monitors for an extended free-living period (72 hours), with the SW used as the criterion device. Mean absolute percent error (MAPE) was calculated for overground walking and free-living protocols and compared across monitors. Results: For overground walking, the OM, NL, and SW performed well (<5% MAPE) for normal and brisk pace walking trials, and also when trials were analyzed by actual speeds. The AG and FF had significantly greater MAPE for overground walking trials (11.9–14.7%). Trimester did affect device accuracy to some degree for the AG, FF, and SW, with error being lower in the third trimester compared to the second. For the free-living period, the OM, NL, AG, and FF significantly underestimated (>32% MAPE) actual steps taken per day as measured by the criterion SW (M [SD] = 9,350 [3,910]). MAPE for the OM was particularly high (45.3%). Conclusion: The OM, NL, and SW monitors are valid measures for overground step-counting during pregnancy walking. However, the OM and NL significantly underestimate steps by second and third trimester pregnant women in free-living conditions.


PLoS ONE ◽  
2019 ◽  
Vol 14 (1) ◽  
pp. e0211231 ◽  
Author(s):  
Jamie E. Collins ◽  
Heidi Y. Yang ◽  
Taylor P. Trentadue ◽  
Yusi Gong ◽  
Elena Losina

Foods ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 1500
Author(s):  
Hyeon-Ki Kim ◽  
Takuya Nanba ◽  
Mamiho Ozaki ◽  
Hanako Chijiki ◽  
Masaki Takahashi ◽  
...  

To examine the effects of the intake of a snack containing dietary fiber under free-living conditions on postprandial glucose levels in older adults, nine healthy older adults aged 76.9 ± 1.6 years (mean ± standard error) completed two crossover trials: 1) regular snack (BISCUIT) intake and 2) intake of snacks with a high dietary fiber content (DF-BISCUIT). In both trials, each participant consumed either BISCUIT or DF-BISCUIT between lunch and dinner time for 1 week. During the intervention, the blood glucose levels of all the subjects were observed using a continuous glucose monitoring system. Lower 24 h blood glucose levels were yielded in the DF-BISCUIT than the BISCUIT trials. Moreover, compared to the BISCUIT trials, the blood glucose levels after dinner and areas under the curve (AUCs) were significantly decreased in the DF-BISCUIT treatments. The blood glucose levels and AUCs after the intake of the next day’s breakfast were suppressed in the DF-BISCUIT treatments compared to those in the BISCUIT trials. Our data indicate that the intake of snacks with a high dietary fiber content under free-living conditions is an effective way to restrain postprandial glucose levels and that the effect lasts until breakfast the next day.


2021 ◽  
Vol 9 ◽  
Author(s):  
Gergely Ráthonyi ◽  
Viktor Takács ◽  
Róbert Szilágyi ◽  
Éva Bácsné Bába ◽  
Anetta Müller ◽  
...  

Inadequate physical activity is currently one of the leading risk factors for mortality worldwide. University students are a high-risk group in terms of rates of obesity and lack of physical activity. In recent years, activity trackers have become increasingly popular for measuring physical activity. The aim of the present study is to examine whether university students in Hungary meet the health recommendations (10,000 steps/day) for physical activity and investigate the impact of different variables (semester-exam period, days-weekdays, days, months, sex) on the level of physical activity in free-living conditions for 3 months period. In free-living conditions, 57 healthy university students (male: 25 female: 32 mean age: 19.50 SD = 1.58) wore MiBand 1S activity tracker for 3 months. Independent sample t-tests were used to explore differences between sexes. A One-way analysis of variance (ANOVA) was used to explore differences in measures among different grouping variables and step count. A Two-way ANOVA was conducted to test for differences in the number of steps by days of the week, months, seasons and for sex differences. Tukey HSD post-hoc tests were used to examine significant differences. Students in the study achieved 10,000 steps per day on 17% of days (minimum: 0%; maximum: 76.5%; median: 11.1%). Unfortunately, 70% of the participants did not comply the 10,000 steps at least 80% of the days studied. No statistical difference were found between sexes. However, significant differences were found between BMI categories (underweight &lt;18.50 kg/m2; normal range 18.50–24.99 kg/m2; overweight: 25.00–29.99 kg/m2 obese &gt; 30 kg/m2, the number of steps in the overweight category was significantly lower (F = 72.073, p &lt; 0.001). The average daily steps were significantly higher in autumn (t = 11.457, p &lt; 0.001) than in winter. During exam period average steps/day were significantly lower than during fall semester (t = 13.696, p &lt; 0.001). On weekdays, steps were significantly higher than on weekends (F = 14.017, p &lt; 0.001), and even within this, the greatest physical activity can be done by the middle of the week. Our data suggest that university students may be priority groups for future physical activity interventions. Commercial activity trackers provide huge amount of data for relatively low cost therefore it has the potential to objectively analyze physical activity and plan interventions.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6245
Author(s):  
Kaja Kastelic ◽  
Marina Dobnik ◽  
Stefan Löfler ◽  
Christian Hofer ◽  
Nejc Šarabon

Wrist-worn consumer-grade activity trackers are popular devices, developed mainly for personal use. This study aimed to explore the validity, reliability and sensitivity to change of movement behaviors metrics from three activity trackers (Polar Vantage M, Garmin Vivoactive 4s and Garmin Vivosport) in controlled and free-living conditions when worn by older adults. Participants (n = 28; 74 ± 5 years) underwent a videotaped laboratory protocol while wearing all three trackers. On a separate occasion, participants (n = 17 for each of the trackers) wore one (randomly assigned) tracker and a research-grade activity monitor ActiGraph wGT3X-BT simultaneously for six consecutive days. Both Garmin trackers showed excellent performance for step counts, with a mean absolute percentage error (MAPE) below 20% and intraclass correlation coefficient (ICC2,1) above 0.90 (p < 0.05). The MAPE for sleep time was within 10% for all the trackers tested, while it was far beyond 20% for all other movement behaviors metrics. The results suggested that all three trackers could be used for measuring sleep time with a high level of accuracy, and both Garmin trackers could also be used for step counts. All other output metrics should be used with caution. The results provided in this study could be used to guide choice on activity trackers aiming for different purposes—individual use, longitudinal monitoring or in clinical trial setting.


Sign in / Sign up

Export Citation Format

Share Document