scholarly journals Development of an Enzyme-Linked Immunosorbent Assay for Serodiagnosis of Ringworm Infection in Cattle

2013 ◽  
Vol 20 (8) ◽  
pp. 1150-1154 ◽  
Author(s):  
Elena Tatiana Băguţ ◽  
Ludivine Cambier ◽  
Marie-Pierre Heinen ◽  
Vasile Cozma ◽  
Michel Monod ◽  
...  

ABSTRACTThe aim of this study was to develop an in-house enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of ringworm infection in cattle. We used available recombinant forms ofTrichophyton rubrumdipeptidyl peptidase V (TruDppV) andT. rubrumleucin aminopeptidase 2 (TruLap2), which are 98% identical toTrichophyton verrucosumorthologues. Field serum samples from 135 cattle with ringworm infection, as confirmed by direct microscopy, fluorescence microscopy, and PCR, and from 55 cattle without any apparent skin lesions or history of ringworm infection that served as negative controls were used. Sensitivities, specificities, and positive and negative predictive values were determined to evaluate the diagnostic value of our ELISA. Overall, the ELISAs based on recombinant TruDppV and TruLap2 discriminated well between infected animals and healthy controls. Highly significant differences (P< 0.0001, Mann-Whitney U test) were noted between optical density values obtained when sera from infected versus control cattle were tested. The ELISA developed for the detection of specific antibodies against DppV gave 89.6% sensitivity, 92.7% specificity, a 96.8% positive predictive value, and a 78.4% negative predictive value. The recombinant TruLap2-based ELISA displayed 88.1% sensitivity, 90.9% specificity, a 95.9% positive predictive value, and a 75.7% negative predictive value. To the best of our knowledge, this is the first ELISA based on recombinant antigens for assessing immune responses to ringworm infection in cattle; it is particularly suitable for epidemiological studies and also for the evaluation of vaccines and/or vaccination procedures.

2012 ◽  
Vol 19 (8) ◽  
pp. 1238-1242 ◽  
Author(s):  
N. Ghosh ◽  
A. K. Goel

ABSTRACTAnthrax caused byBacillus anthracisis a public health problem in several developing countries whose main source of income is farming. Anthrax is a disease of herbivorous animals, and humans can be infected by handling infected animals or contaminated animal products. Specific diagnostic tests are unavailable in India for the detection and confirmation of cutaneous anthrax in humans. Here, we describe the development of an enzyme-linked immunosorbent assay (ELISA) for detection of serum antibodies againstBacillus anthracisprotective antigen in the Indian population. A total of 405 serum samples collected from different groups were tested by the developed ELISA. The assay provided a specificity of 99.41% (95% confidence interval [CI], 97.89 to 99.93) and a sensitivity of 100% (CI, 94.4 to 100) using a cutoff value of 0.29 ELISA unit (EU). The positive predictive value (PPV) and negative predictive value (NPV) of the assay were 97% and 100%, respectively. The efficiency and J index for the reliability of the assay were 99.5% and 0.994, respectively. The assay can be a very useful tool for surveillance as well as for diagnosis of cutaneous anthrax cases in India.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


2013 ◽  
Vol 57 (9) ◽  
pp. 4578-4580 ◽  
Author(s):  
Nathalie Tijet ◽  
David Boyd ◽  
Samir N. Patel ◽  
Michael R. Mulvey ◽  
Roberto G. Melano

ABSTRACTThe Carba NP test was evaluated against a panel of 244 carbapenemase- and non-carbapenemase-producingEnterobacteriaceaeandPseudomonas aeruginosaisolates. We confirmed the 100% specificity and positive predictive value of the test, but the sensitivity and negative predictive value were 72.5% and 69.2%, respectively, and increased to 80% and 77.3%, respectively, using a more concentrated bacterial extract. False-negative results were associated with mucoid strains or linked to enzymes with low carbapenemase activity, particularly OXA-48-like, which has emerged globally in enterobacteria.


2009 ◽  
Vol 11 (10) ◽  
pp. 881-884 ◽  
Author(s):  
Annamaria Pratelli ◽  
Kadir Yesilbag ◽  
Marcello Siniscalchi ◽  
Ebru Yalçm ◽  
Zeki Yilmaz

Feline sera from Bursa province (Turkey) were assayed for coronavirus antibody using an enzyme-linked immunosorbent assay (ELISA). The study was performed on 100 sera collected from cats belonging to catteries or community shelters and to households. The serum samples were initially tested with the virus neutralisation (VN) test and the results were then compared with the ELISA. The VN yielded 79 negative and 21 positive sera but the ELISA confirmed only 74 as negative. The ELISA-negative sera were also found to be free of feline coronoviruses-specific antibodies by Western blotting. Using the VN as the gold standard test, ELISA had a sensitivity of 100% and a specificity of 93.6%, with an overall agreement of 95%. The Kappa (κ) test indicated high association between the two tests (κ=0.86, 95% confidence interval (CI) 0.743–0.980). The positive predictive value (PPV) was 0.8, and the negative predictive value (NPV) was 0.93. The prevalence of FCoV II antibodies in the sampled population based on the gold standard was 62% (95% CI 0.44–0.77) among multi-cat environments, and 4% (95% CI 0.01–0.11) among single cat households.


2021 ◽  
Vol 24 (2) ◽  
pp. 196-203
Author(s):  
Elahe Fini ◽  
◽  
Neda Nasirian ◽  
Bahram Hosein Beigy ◽  
◽  
...  

Background and Aim: Ovarian cancer is among the most common cancers in women worldwide. CA125 is the most frequent biomarker used in the screening for ovarian cancer. CA125 has no high sensitivity and specificity as a screening test in the medical community; however, because of being simple and noninvasive, it is almost always requested for evaluation and ruling out cancer. It plays an important role in the treatment and post-treatment process, the prediction of prognosis, and the relapse of the disease. The present study aimed to determine the relationship between a high level of CA125 tumor marker and ovarian cancer by detecting spesivity, sensivity, positive and negative predictive values. Methods & Materials: In this cross-sectional study, all cases undergoing CA125 test in Velayat Hospital in 2017-1028 were evaluated for having ovarian cancer. In addition, the CA125 level was compared between healthy individuals and patients with ovarian cancer. Finally, the obtained data were analyzed using SPSS. Ethical Considerations: The present study was approved by the Qazvin University of Medical Sciences (Ethics Code: IR.QUMS.REC.1396.316). Results: In this study, 35.3% of the study participants received a definite diagnosis of ovarian cancer. Generally, CA125 values were negative in 41.8% and positive in.58.2% of the study subjects. The sensitivity of the test was measured as 80.1%, the specivity as 53.6%, the positive predictive value equaled 48.4%, and the negative predictive value was measured as 83%. There was a significant relationship between age and the presence of ovarian cancer, and serum CA125 levels. Conclusion: The present study suggested that age and the serum level of CA125 were statistically significant. Finally, CA125 levels were significantly related to ovarian cancer. It provided moderate specivity and specivity as well as low positive predictive value and high negative predictive value as a tumor marker; it is valuable for ruling out of tumor but not appropriate as a screening test.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Konuralp Yakar

Aim. To compare the clinical performance of the Spot Vision Screener used to detect amblyopia risk factors (ARFs) in children before and after induction of cycloplegia; the children were referred because they met the screening criteria of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS). Methods. The Spot Vision Screener and a standard autorefractometer were used to examine 200 eyes of 100 children aged 3–10 years, before and after cycloplegia induction, in terms of ARFs. Sensitivity, specificity, and positive and negative predictive values for the detection of significant refractive errors were measured using the AAPOS referral criteria. It was explored that Spot Screener data were affected by cycloplegia. The extent of agreement between cycloplegic/noncycloplegic photoscreening data and cycloplegic autorefraction measurements was assessed using Wilcoxon and Spearman correlation analyses. Results. The Spot’s sensitivity was improved from 60.9% to 85.3% and specificity from 94.9% to 87.4% with cycloplegia compared to cycloplegic standard autorefractometer results. The positive predictive value of Spot was 75.7%, and the negative predictive value was 90.4% without cycloplegia. With cycloplegia, the positive predictive value of Spot was 63.6% and the negative predictive value was 95.8%. Conclusions. The Spot Screener afforded moderate sensitivity and high specificity prior to cycloplegia. The sensitivity and negative predictive value improved after induction of cycloplegia. Examiners should be aware of the effects of cycloplegia on their findings.


2013 ◽  
Vol 21 (1) ◽  
pp. 96-106 ◽  
Author(s):  
Lourena E. Costa ◽  
Mayara I. S. Lima ◽  
Miguel A. Chávez-Fumagalli ◽  
Daniel Menezes-Souza ◽  
Vivian T. Martins ◽  
...  

ABSTRACTVisceral leishmaniasis (VL) is a zoonotic disease that is endemic to Brazil, where dogs are the main domestic parasite reservoirs, and the percentages of infected dogs living in regions where canine VL (CVL) is endemic have ranged from 10% to 62%. Despite technological advances, some problems have been reported with CVL serodiagnosis. The present study describes a sequential subtractive selection through phage display technology from polyclonal antibodies of negative and positive sera that resulted in the identification of potential bacteriophage-fused peptides that were highly sensitive and specific to antibodies of CVL. A negative selection was performed in which phage clones were adhered to purified IgGs from healthy andTrypanosoma cruzi-infected dogs to eliminate cross-reactive phages. The remaining supernatant nonadhered phages were submitted to positive selection against IgG from the blood serum of dogs that were infected withLeishmania infantum. Phage clones that adhered to purified IgGs from the CVL-infected serum samples were selected. Eighteen clones were identified and their reactivities tested by a phage enzyme-linked immunosorbent assay (phage-ELISA) against the serum samples from infected dogs (n= 31) compared to those from vaccinated dogs (n= 21), experimentally infected dogs with cross-reactive parasites (n= 23), and healthy controls (n= 17). Eight clones presented sensitivity, specificity, and positive and negative predictive values of 100%, and they showed no cross-reactivity withT. cruzi- orEhrlichia canis-infected dogs or with dogs vaccinated with two different commercial CVL vaccines in Brazil. Our study identified eight mimotopes ofL. infantumantigens with 100% accuracy for CVL serodiagnosis. The use of these mimotopes by phage-ELISA proved to be an excellent assay that was reproducible, simple, fast, and inexpensive, and it can be applied in CVL-monitoring programs.


2016 ◽  
Vol 54 (6) ◽  
pp. 1557-1565 ◽  
Author(s):  
Martin Heller ◽  
Nimmo Gicheru ◽  
Georgina Tjipura-Zaire ◽  
Cecilia Muriuki ◽  
Mingyan Yu ◽  
...  

Contagious bovine pleuropneumonia (CBPP) is a severe respiratory disease that is widespread in sub-Saharan Africa. It is caused byMycoplasma mycoidessubsp.mycoides, a bacterium belonging to theMycoplasma mycoidescluster. In the absence of an efficient CBPP vaccine, improved and easy-to-use diagnostic assays for recurrent testing combined with isolation and treatment of positive animals represent an option for CBPP control in Africa. Here we describe the comprehensive screening of 17 immunogenicMycoplasma mycoidessubsp.mycoidesproteins using well-characterized bovine sera for the development of a novel cocktail enzyme-linked immunosorbent assay (ELISA) for laboratory use. Two recombinantMycoplasmaimmunogens, MSC_0136 and MSC_0636, were used to set up a standardized cocktail ELISA protocol. According to the results from more than 100 serum samples tested, the sensitivity and specificity of the novel cocktail ELISA were 85.6% and 96.4%, respectively, with an overall diagnostic accuracy comparable to that of the Office International des Epizooties (OIE)-prescribed serological assays. In addition, we provide a proof of principle for a field-applicable, easy-to-use commercially produced prototype lateral-flow test for rapid (<30-min) diagnosis of CBPP.


Author(s):  
Iqbal Rashid ◽  
Langalibalele H. Mabuza ◽  
Indiran Govender ◽  
Deidre Pretorius

Background: Optimum sputum results for acid-fast bacilli (AFB) microscopy are linked to a sputum quantity of at least 5.0 mL. This study was aimed at establishing the effect of sputum quantity in the pick-up rate of AFB microscopy by comparing sputum samples of 5.0 mL and 2.0 mL.Methods: An analytical cross-sectional study was carried out at the Dr George Mukhari Hospital (DGMH) in Pretoria, South Africa, from 05 January 2007 to 04 January 2008.Two sputum samples, 5.0 mL and 2.0 mL, were collected from each of the 330 adult PTB (pulmonary tuberculosis) suspects. Fluorescence microscopy was used in the sputum analysis. The yield through microscopy of the 2.0 mL specimen versus the 5.0 mL specimen was compared and analysed, using culture results as the gold standard.Results: From a sample of 330 specimens, 77 tested AFB positive on microscopy. In the 5.0 mL samples, the sensitivity was 76.6% (95% CI, 66.0% – 84.7%), specificity 99.6% (95% CI 97.8% – 99.9%), positive predictive value (PV+) 98.3% (95% CI 91.1% – 99.7%), negative predictive value (PV-) 93.3% (95% CI 89.7% – 95.7%), the likelihood ratio (LR) for a positive microscopy 192 and the LR for a negative test was 0.23. In the 2.0 mL specimens, the sensitivity was 75.3% (95% CI 64.6% – 83.6%), specificity 99.2% (95% CI 97.1% – 99.8%), positive predictive value (PV+) 96.7% (95% CI 88.6% – 99.1%), negative predictive value (PV-) 93.0% (95% CI 89.3% – 95.4%), the LR for a positive microscopy was 94 and 0.25 for a negative microscopy. There was a statistically significant association (p-value < 0.001) between the microscopy and culture tests in both the 5.0 mL and the 2.0 mL specimen categories. The strength of association between the microscopy and culture, as indicated by the kappa test was 0.83 and 0.81 in the 5.0 mL and 2.0 mL categories, respectively.Conclusion: Compared to the 2.0 mL specimen category, the yield for AFB microscopy in the 5.0 mL specimen category was consistently superior, as indicated by the higher sensitivity, specificity, predictive values and the likelihood ratios in the 5.0 mL specimen category. It is recommended that sputum specimen collection for AFB microscopy should aim for a minimum volume of 5.0 mL.


2016 ◽  
Vol 76 (1) ◽  
pp. 119-125 ◽  
Author(s):  
Aase Haj Hensvold ◽  
Thomas Frisell ◽  
Patrik K E Magnusson ◽  
Rikard Holmdahl ◽  
Johan Askling ◽  
...  

ObjectiveAnti-citrullinated protein antibodies (ACPA) are highly specific for rheumatoid arthritis (RA), but the diagnostic accuracy of ACPA in the general population has not been thoroughly assessed. We aimed to assess the diagnostic accuracy of ACPA for RA in the general population and to further characterise the citrullinated peptide recognition pattern.MethodsSerum samples from a large population-representative twin cohort consisting of 12 590 individuals were analysed for the presence of ACPA using anti-CCP2 ELISA. All ACPA-positive samples were further tested on ELISAs for four peptide-specific ACPA. RA cases were identified by linkage to the Swedish National Patient Register at inclusion and after a median follow-up of 37 months (IQR 31–49).Results350 out of 12 590 individuals had a positive anti-CCP2 test, measuring ACPA. Of these, 103 had an RA diagnosis at the time of blood donation and inclusion. During a median follow-up of 3 years, an additional 21 of the remaining 247 ACPA-positive individuals developed RA. Overall, a positive anti-CCP2 test had a positive predictive value of 29% for prevalent RA at inclusion (negative predictive value of 99.6%). High titres (>3× cut-off) of anti-CCP2 increased the positive predictive value to 48% (negative predictive value of 99.5%). ACPA-positive individuals without RA had lower anti-CCP2 titres and fewer peptide-specific ACPA than ACPA-positive patients with RA and higher C reactive protein levels than ACPA-negative individuals without RA.ConclusionPresence of ACPA and especially high titres of anti-CCP2 have a high diagnostic accuracy for an RA diagnosis in a population setting.


Sign in / Sign up

Export Citation Format

Share Document