scholarly journals Novel DNA Markers for Identification of Actinobacillus pleuropneumoniae

Author(s):  
Gun Srijuntongsiri ◽  
Atiwat Mhoowai ◽  
Sukuma Samngamnim ◽  
Pornchalit Assavacheep ◽  
Janine T. Bossé ◽  
...  

Species-specific markers are crucial for infectious disease diagnostics. Mutations within a marker sequence can lead to false-negative results, inappropriate treatment, and economic loss.

1996 ◽  
Vol 70 (3) ◽  
pp. 219-222 ◽  
Author(s):  
A. Mathis ◽  
P. Deplazes ◽  
J. Eckert

AbstractFor the sensitive detection of eggs ofEchinococcus multilocularisin fox faeces by PCR we have evaluated a method based on the previous concentration of helminth eggs by a combination of sequential sieving of faecal samples and flotation of the eggs in zinc chloride solution. The eggs were microscopically detected in the fractions retained in 40 and 20µm mesh sieves. DNA of the taeniid eggs retained in the 20 µm sieve was obtained after alkaline lysis and PCR was performed usingE. multilocularisspecies-specific primers. Compared to the parasitological findings after examination of the small intestines of the foxes, the specificity of the PCR was 100% (no false-positive result with 20 foxes free ofE. multilocularis) and the sensitivity was 94% (33 positive results from total 35 foxes proven to be infected withE. multilocularis). Both false-negative results were obtained with faeces from foxes harbouring immature worms. Using faecal volumes between 2 and 20 ml, no inhibition of PCR was observed as was demonstrated by the amplification of size-modified target in parallel reactions. The tests were undertaken with fresh faeces stored in 70% ethanol, but egg detection by PCR was also possible after inactivation of eggs by freezing the faeces at −80°C for one week or by incubation at +70°C for 2 h.


2018 ◽  
Vol 56 (3) ◽  
pp. 397-402 ◽  
Author(s):  
Aldo Clerico ◽  
Lucia Belloni ◽  
Cinzia Carrozza ◽  
Mario Correale ◽  
Ruggero Dittadi ◽  
...  

AbstractIt is well known that the results of immunoassay methods can be affected by specific or non-specific interferences, ranging from 0.4% to 4.0%. The presence of interference may greatly compromise the accuracy of immunoassay analyses causing an error in the measurement, producing false-positive or false-negative results. From a clinical point of view, these analytical errors may have serious implications for patient care because they can cause misdiagnosis or inappropriate treatment. Unfortunately, it is a very difficult task to identify the irregular analytical errors related to immunoassay methods because they are not detectable by normal laboratory quality control procedures, are reproducible within the test system, may be clinically plausible and are relatively rare. The first line of defense against erroneous results is to use in laboratory practice only immunoassay systems with the highest level of robustness against interference. The second line of defense is always taking into account the possibility of interference in immunoassay results. A correct approach should be addressed on identification of samples at high risk of interference. The attainment of this goal requires a critical review of the test result in relation to patient’s clinical conditions and literature data, taking into account the analytical characteristics of the immunoassay system. The experts in immunoassay systems should make every effort to find some specific and reliable quality indicators for irregular analytical errors in order to better detect and monitor erroneous immunoassay results due to specific or non-specific interferences.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Coronaviruses ◽  
2020 ◽  
Vol 01 ◽  
Author(s):  
Maria Silvia De Feo ◽  
Viviana Frantellizzi ◽  
Giuseppe De Vincentis

Background: We present the case of a 55-year-old woman, admitted to the Infectious Disease Department of Policlinico Umberto I, Rome, in mid-March 2020, with suspicion of COVID-19 infection. Objective: The rRT-PCR was negative and the following CT scan, performed to exclude false-negative results and help diagnosis, was inconclusive. Methods: It was decided to submit the patient to 99mTc-HMPAO-labelled leukocyte scan. Results: This exam led to the diagnosis of infective endocarditis. Conclusion: In the present pandemic scenario, 99mTc-HMPAO-labelled leukocyte scan represents a reliable imaging technique for differential diagnosis with COVID-19 in patients with confusing clinical signs, possible false-negative rRT-PCR results and inconclusive CT scan.


Author(s):  
Hyoung-Jin Moon ◽  
Won Lee ◽  
Ji-Soo Kim ◽  
Eun-Jung Yang ◽  
Hema Sundaram

Abstract Background Aspiration testing before filler injection is controversial. Some believe that aspiration can help prevent inadvertent intravascular injection, while others cite false-negative results and question its value given that the needle position always changes somewhat during injection procedures. Objectives To test the relation of false-negative results to the viscosity of the material within the needle lumen and determine whether a less viscous material within the needle lumen could decrease the incidence of false-negative results. Methods In vitro aspiration tests were performed using 30-G and 27-G needle gauges, two cross-linked hyaluronic acid fillers, normal saline bags pressurized at 140 and 10 mmHg to mimic human arterial and venous pressures, and three needle lumen conditions (normal saline, air, and filler). Testing was repeated three times under each study condition (72 tests in total). For in vivo correlation, aspiration tests were performed on femoral arteries and central auricular veins in three rabbits (4–5 aspirations per site, 48 tests in total). Results In vitro and in vivo testing using 30-G needles containing filler both showed false-negative results on aspiration testing. In vitro and in vivo testing using needles containing saline or air showed positive findings. Conclusions False-negative results from aspiration testing may be reduced by pre-filling the needle lumen with saline rather than a filler. The pressurized system may help overcome challenges of animal models with intravascular pressures significantly different from those of humans. The adaptability of this system to mimic various vessel pressures may facilitate physiologically relevant studies of vascular complications.


Viruses ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 730
Author(s):  
Magda Rybicka ◽  
Ewa Miłosz ◽  
Krzysztof Piotr Bielawski

At present, the RT-PCR test remains the gold standard for early diagnosis of SARS-CoV-2. Nevertheless, there is growing evidence demonstrating that this technique may generate false-negative results. Here, we aimed to compare the new mass spectrometry-based assay MassARRAY® SARS-CoV-2 Panel with the RT-PCR diagnostic test approved for clinical use. The study group consisted of 168 suspected patients with symptoms of a respiratory infection. After simultaneous analysis by RT-PCR and mass spectrometry methods, we obtained discordant results for 17 samples (10.12%). Within fifteen samples officially reported as presumptive positive, 13 were positive according to the MS-based assay. Moreover, four samples reported by the officially approved RT-PCR as negative were positive in at least one MS assay. We have successfully demonstrated superior sensitivity of the MS-based assay in SARS-CoV-2 detection, showing that MALDI-TOF MS seems to be ideal for the detection as well as discrimination of mutations within the viral genome.


Sign in / Sign up

Export Citation Format

Share Document