Estimation of Partial Discharge Parameters in GIS Using Acoustic Emission Techniques

1998 ◽  
Vol 06 (04) ◽  
pp. 403-419 ◽  
Author(s):  
Nandini Gupta ◽  
T. S. Ramu

Electrical discharge activity within an electrical power apparatus has detrimental effects on the insulating components of the system, and thus its prognosis and diagnosis are of utmost importance. Traditional electrical methods have been replaced by newer techniques such as acoustic detection. Among these, acoustic methods possess certain inherent advantages, especially where complex electrical systems like GIS are involved. The major concerns therein are the estimation of the magnitude of the discharge level as well as location of the source of discharge. The present work addresses, on a theoretical basis, problems connected with identification, measurement and location of electrical discharges, in particular in GIS. Models for the inception and propagation of p.d. within GIS have been proposed. This study, based essentially on a numerical simulation model, corroborates many of the experimental findings reported in the existing literature, and in addition attempts to suggest newer directions in magnitude estimation and location of p.d.

Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2223 ◽  
Author(s):  
Sayed A. Ward ◽  
Adel El-Faraskoury ◽  
Mohamed Badawi ◽  
Shimaa A. Ibrahim ◽  
Karar Mahmoud ◽  
...  

Power transformers are considered important and expensive items in electrical power networks. In this regard, the early discovery of potential faults in transformers considering datasets collected from diverse sensors can guarantee the continuous operation of electrical systems. Indeed, the discontinuity of these transformers is expensive and can lead to excessive economic losses for the power utilities. Dissolved gas analysis (DGA), as well as partial discharge (PD) tests considering different intelligent sensors for the measurement process, are used as diagnostic techniques for detecting the oil insulation level. This paper includes two parts; the first part is about the integration among the diagnosis results of recognized dissolved gas analysis techniques, in this part, the proposed techniques are classified into four techniques. The integration between the different DGA techniques not only improves the oil fault condition monitoring but also overcomes the individual weakness, and this positive feature is proved by using 532 samples from the Egyptian Electricity Transmission Company (EETC). The second part overview the experimental setup for (66/11.86 kV–40 MVA) power transformer which exists in the Egyptian Electricity Transmission Company (EETC), the first section in this part analyzes the dissolved gases concentricity for many samples, and the second section illustrates the measurement of PD particularly in this case study. The results demonstrate that precise interpretation of oil transformers can be provided to system operators, thanks to the combination of the most appropriate techniques.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 909
Author(s):  
David W. Upton ◽  
Keyur K. Mistry ◽  
Peter J. Mather ◽  
Zaharias D. Zaharis ◽  
Robert C. Atkinson ◽  
...  

The lifespan assessment and maintenance planning of high-voltage power systems requires condition monitoring of all the operational equipment in a specific area. Electrical insulation of electrical apparatuses is prone to failure due to high electrical stresses, and thus it is a critical aspect that needs to be monitored. The ageing process of the electrical insulation in high voltage equipment may accelerate due to the occurrence of partial discharge (PD) that may in turn lead to catastrophic failures if the related defects are left untreated at an initial stage. Therefore, there is a requirement to monitor the PD levels so that an unexpected breakdown of high-voltage equipment is avoided. There are several ways of detecting PD, such as acoustic detection, optical detection, chemical detection, and radiometric detection. This paper focuses on reviewing techniques based on radiometric detection of PD, and more specifically, using received signal strength (RSS) for the localization of faults. This paper explores the advantages and disadvantages of radiometric techniques and presents an overview of a radiometric PD detection technique that uses a transistor reset integrator (TRI)-based wireless sensor network (WSN).


2019 ◽  
Vol 28 ◽  
pp. 01037 ◽  
Author(s):  
Maciej Kozak

The paper presents the background and results of numerical simulation and experimental research of a system using auctioneering diodes used to distribute the electrical power between two power converters connected with intermediate circuits in parallel, direct connection. Presented non-isolated power distribution system which utilizes blocking diodes placed in DC branches are used in the selected ship's electrical systems, however, they create problems related to control and handling ground faults. Another issue occurring during the operation of this type of systems is increased heat dissipation while diodes switching. Selected problems related to the operation of experimental system have been identified by means of simulation studies and experiments carried out in a 11 kVA laboratory system and the theoretical basis along with results are provided in the article.


2019 ◽  
Vol 5 (2) ◽  
Author(s):  
Nicolás Alejandro Malinovsky

This work shows the introduction of the Electrical Power System Analysis (etap) software as a calculation and analysis tool for power electrical systems of the nuclear power plants (NPP) under the orbit of Nucleoeléctrica Argentina S.A (NASA). Through the use of the software, the model of the electrical power system of the Atucha II NPP was developed. To test the functionality of the modeled electrical power circuit, studies of load flow and short-circuit analysis were conducted, yielding satisfactory results, which were contrasted with the plant design values. Once the model has been validated, this will be the basis for carrying out different studies in the plant through simulation. Furthermore, with the incorporation of etap as a fundamental calculation and analysis tool for power electrical systems at the company's engineering departments, it is expected to improve the safety, operation, quality, reliability, and maintenance of both the Atucha II NPP electrical power system and the other nuclear power plants operated by Nucleoeléctrica Argentina S.A.


2013 ◽  
Vol 64 (4) ◽  
Author(s):  
M. M. Yaacob ◽  
Malik Abdulrazzaq Alsaedi

In partial discharge (PD) phenomenon energy is emitted as electromagnetic emission, acoustic emission and chemical reactions as ozone formation and nitrous oxide gases. One of the continuous conditions monitoring process is done in high voltage equipments such as power transformer. This paper deals with a short review on PD detection methods regarding high-voltage equipments such as electrical detection, chemical detection, acoustic detection and optical detection. Also, new technique for PD signal monitoring in power transformer call as chromatic in the present. The chromatic approach shows the ability to quantifying information content of PD signal by chromatic parameters hue (H), saturation (S) and lightness (L), which can be related to characteristics of PD signal. The chromatic approach shows the ability to yielding new patterns, which monitoring indications of the discharges signals with high accurac and without noise.