Improved in vitro rheological system for studying the effect of fluid shear stress on cultured cells

1993 ◽  
Vol 265 (1) ◽  
pp. C289-C298 ◽  
Author(s):  
H. J. Schnittler ◽  
R. P. Franke ◽  
U. Akbay ◽  
C. Mrowietz ◽  
D. Drenckhahn

A rheological in vitro system has been developed to study and quantify cellular adhesion under precisely defined external shear forces. The system is similar to a cone-and-plate viscosimeter. A rotating transparent cone produces both steady and pulsatile flow profiles on cultured cells. Direct visualization of cells by phase-contrast or fluorescence optics and connection of the optical system to a computer-controlled x/y-linear stage allows automatic recording of any point of the cell cultures. With the use of up to 12 individual rheological units, this setup allows the quantitative analysis of cell substrate adhesion by determination of cell detachment kinetics. Two examples of application of this rheological system have been studied. First, we show that the extracellular matrix protein laminin strongly increases endothelial cell adhesion under fluid shear stress. In a second approach, we obtained further support for the concept that shear stress-induced formation of actin filament stress fibers is important for endothelial cells to resist the fluid shear stress; inhibition of stress fiber formation by doxorubicin resulted in significant detachment of endothelial cells exposed to medium levels of fluid shear stress (5 dyn/cm2). No detachment was seen under resting conditions.

2000 ◽  
Vol 20 (3) ◽  
pp. 617-623 ◽  
Author(s):  
Boris-Wolfgang Hochleitner ◽  
Elisabeth-Olga Hochleitner ◽  
Peter Obrist ◽  
Thomas Eberl ◽  
Albert Amberger ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Sujuan Duan ◽  
Yingjie Li ◽  
Yanyan Zhang ◽  
Xuan Zhu ◽  
Yan Mei ◽  
...  

Purpose. Corneal endothelial cells are usually exposed to shear stress caused by the aqueous humour, which is similar to the exposure of vascular endothelial cells to shear stress caused by blood flow. However, the effect of fluid shear stress on corneal endothelial cells is still poorly understood. The purpose of this study was to explore whether the shear stress that results from the aqueous humour influences corneal endothelial cells. Methods. An in vitro model was established to generate fluid flow on cells, and the effect of fluid flow on corneal endothelial cells after exposure to two levels of shear stress for different durations was investigated. The mRNA and protein expression of corneal endothelium-related markers in rabbit corneal endothelial cells was evaluated by real-time PCR and western blotting. Results. The expression of the corneal endothelium-related markers ZO-1, N-cadherin, and Na+-K+-ATPase in rabbit corneal endothelial cells (RCECs) was upregulated at both the mRNA and protein levels after exposure to shear stress. Conclusion. This study demonstrates that RCECs respond favourably to fluid shear stress, which may contribute to the maintenance of corneal endothelial cell function. Furthermore, this study also provides a theoretical foundation for further investigating the response of human corneal endothelial cells to the shear stress caused by the aqueous humour.


1986 ◽  
Vol 83 (7) ◽  
pp. 2114-2117 ◽  
Author(s):  
P. F. Davies ◽  
A. Remuzzi ◽  
E. J. Gordon ◽  
C. F. Dewey ◽  
M. A. Gimbrone

2020 ◽  
Author(s):  
Thomas Brendan Smith ◽  
Alessandro Marco De Nunzio ◽  
Kamlesh Patel ◽  
Haydn Munford ◽  
Tabeer Alam ◽  
...  

Fluid shear stress is a key modulator of cellular physiology in vitro and in vivo, but its effects are under-investigated due to requirements for complicated induction methods. Herein we report the validation of ShearFAST; a smartphone application that measures the rocking profile on a standard laboratory cell rocker and calculates the resulting shear stress arising in tissue culture plates. The accuracy with which this novel approach measured rocking profiles was validated against a graphical analysis, and also against measures reported by an 8-camera motion tracking system. ShearFASTs angle assessments correlated well with both analyses (r ≥0.99, p ≤0.001) with no significant differences in pitch detected across the range of rocking angles tested. Rocking frequency assessment by ShearFAST also correlated well when compared to the two independent validatory techniques (r ≥0.99, p ≤0.0001), with excellent reproducibility between ShearFAST and video analysis (mean frequency measurement difference of 0.006 ± 0.005Hz) and motion capture analysis (mean frequency measurement difference of 0.008 ± 0.012Hz). These data make the ShearFAST assisted cell rocker model make it an attractive approach for economical, high throughput fluid shear stress experiments. Proof of concept data presented reveals a protective effect of low-level shear stress on renal proximal tubule cells submitted to simulations of pretransplant storage.


Sign in / Sign up

Export Citation Format

Share Document