Modified protocols improve insulin sensitivity estimation using the minimal model

1987 ◽  
Vol 253 (6) ◽  
pp. E595-E602 ◽  
Author(s):  
Y. J. Yang ◽  
J. H. Youn ◽  
R. N. Bergman

We attempted to improve the precision of the estimation of insulin sensitivity (S1) from the minimal model technique by modifying insulin dynamics during a frequently sampled intravenous glucose tolerance test (FSIGT). Tolbutamide and somatostatin (SRIF) were used to change the insulin dynamics without directly affecting insulin sensitivity. Injection of tolbutamide (100 mg) at t = 20 min provoked an immediate secondary peak in insulin response, resulting in a greater integrated incremental insulin than the standard FSIGT. SRIF, injected at t = -1 min, delayed insulin secretion in proportion to the dose without any change in magnitude. Computer simulation was used to assess the precision of S1 estimation. Insulin dynamics from both standard and modified protocols were adjusted in magnitude, with the shape unchanged and analyzed to determine the effect of the magnitude of insulin response. Fractional standard deviation was reduced from 73% with the standard insulin profile to 23% with tolbutamide and 18% with the highest dose of SRIF. In addition, the fractional standard deviation of S1 estimates decreased exponentially with increasing magnitude of insulin response. Modified FSIGTs require a smaller insulin response than the standard protocol to achieve the same precision.

2021 ◽  
Vol 12 ◽  
Author(s):  
Joon Ha ◽  
Ranganath Muniyappa ◽  
Arthur S. Sherman ◽  
Michael J. Quon

We address a problem with the Bergman-Cobelli Minimal Model, which has been used for 40 years to estimate SI during an intravenous glucose tolerance test (IVGTT). During the IVGTT blood glucose and insulin concentrations are measured in response to an acute intravenous glucose load. Insulin secretion is often assessed by the area under the insulin curve during the first few minutes (Acute Insulin Response, AIR). The issue addressed here is that we have found in simulated IVGTTs, representing certain contexts, Minimal Model estimates of SI are inversely related to AIR, resulting in artifactually lower SI. This may apply to Minimal Model studies reporting lower SI in Blacks than in Whites, a putative explanation for increased risk of T2D in Blacks. The hyperinsulinemic euglycemic clamp (HIEC), the reference method for assessing insulin sensitivity, by contrast generally does not show differences in insulin sensitivity between these groups. The reason for this difficulty is that glucose rises rapidly at the start of the IVGTT and reaches levels independent of SI, whereas insulin during this time is determined by AIR. The minimal model in effect interprets this combination as low insulin sensitivity even when actual insulin sensitivity is unchanged. This happens in particular when high AIR results from increased number of readily releasable insulin granules, which may occur in Blacks. We conclude that caution should be taken when comparing estimates of SI between Blacks and Whites.


1994 ◽  
Vol 86 (3) ◽  
pp. 317-322 ◽  
Author(s):  
Jonathan W. Swan ◽  
Christopher Walton ◽  
Ian F. Godsland

1. Simplified protocols for the measurement of insulin resistance will facilitate studies of this potentially important variable. 2. Using the euglycaemic clamp as the reference technique, we have assessed the validity of the insulin sensitivity index (inversely related to insulin resistance) obtained using a high-dose (500 mg/kg), unmodified intravenous glucose tolerance test with a 16 point sampling schedule and analysis using the minimal model of glucose disappearance. The two methods were compared in 10 clinically normal subjects and five patients with severe heart failure secondary to coronary heart disease. 3. The insulin sensitivity index of the minimal model was compared with four clamp-derived measures. Correlation coefficients of 0.72–0.92 (P < 0.01−P < 0.001) were obtained between the two methods over a wide range of insulin sensitivity [model values 1.03–14.63 min−1/(pmol/l) × 10−5]. Patients with heart failure had the lowest measures of insulin sensitivity. 4. The high-dose, unmodified intravenous glucose tolerance test with minimal model analysis is a straightforward and economical clinical procedure and provides a valid measure of insulin sensitivity, in health and disease.


2003 ◽  
Vol 105 (5) ◽  
pp. 531-532 ◽  
Author(s):  
Ian F. GODSLAND

After more than 20 years, minimal model analysis of intravenous glucose tolerance test glucose and insulin concentrations continues to be widely employed in studies of insulin sensitivity and insulin resistance. Moreover, problems encountered in solving the minimal model equations continue to find new solutions. Bayesian techniques enable prior knowledge to be incorporated into parameter estimation routines. They offer particular advantages in the measurement of insulin sensitivity with the minimal model, and provide an elegant means of improving model identification success rates and parameter precision. This comment describes the study by Agbaje and colleagues in this issue of Clinical Science that exemplifies a new phase in the evolution of minimal model practice.


2005 ◽  
Vol 2 (3) ◽  
pp. 185-193 ◽  
Author(s):  
SE Pratt ◽  
RJ Geor ◽  
LJ McCutcheon

AbstractThe objective of this study was to determine the relationship between insulin sensitivity and aerobic capacity and serum adipocytokine (leptin, adiponectin) concentrations in 14 mature, unconditioned Standardbred horses (eight mares, six geldings). Each horse underwent a euglycaemic–hyperinsulinaemic clamp (EHC) and a frequently sampled intravenous glucose tolerance test (FSIGT) for assessment of insulin sensitivity. Aerobic capacity was determined by measurement of the peak rate of oxygen uptake (V˙O2peak) during an incremental exercise test (IET). Serum leptin and adiponectin concentrations were measured in baseline samples obtained before tests of insulin sensitivity. Mean body weight, condition score, V˙O2peak and run time during the IET did not differ between the sex groups. However, minimal model analysis of the FSIGT showed that insulin sensitivity (SI, ×10−4 l mU−1 min−1) was higher (P = 0.002) in geldings (4.21±0.78) than in mares (2.43±0.95), while the acute insulin response to glucose (AIRg) and glucose utilization independent of insulin (SG) were significantly higher in mares. Similarly, glucose uptake (M) per unit of serum insulin (I) during the EHC (M/I ratio) tended (P = 0.08) to be higher in geldings than in mares (×10−2 mg kg−1 min−1 per μU ml−1: 2.41±0.64 vs. 1.80±0.51). There was no significant relationship between V˙O2peak and measures of insulin sensitivity. Stepwise multiple linear regression modelling determined that sex (65%) and leptin concentrations (13.7%) accounted for 78.7% of the variance in SI, while 46% of the variance in M/I could be attributed to sex. It was concluded that aerobic capacity is not an important determinant of insulin-mediated glucose disposal in mature, untrained Standardbred horses. Further studies are needed to examine the influence of gender on insulin sensitivity in horses.


1999 ◽  
Vol 277 (3) ◽  
pp. E481-E488 ◽  
Author(s):  
Claudio Cobelli ◽  
Andrea Caumo ◽  
Matteo Omenetto

The intravenous glucose tolerance test (IVGTT) single-compartment minimal model (1CMM) method has recently been shown to overestimate glucose effectiveness and underestimate insulin sensitivity. Undermodeling, i.e., use of single- instead of two-compartment description of glucose kinetics, has been advocated to explain these limitations. We describe a new two-compartment minimal model (2CMM) into which we incorporate certain available knowledge on glucose kinetics. 2CMM is numerically identified using a Bayesian approach. Twenty-two standard IVGTT (0.30 g/kg) in normal humans were analyzed. In six subjects, the clamp-based index of insulin sensitivity ([Formula: see text]) was also measured. 2CMM glucose effectiveness ([Formula: see text]) and insulin sensitivity ([Formula: see text]) were, respectively, 60% lower ( P < 0.0001) and 35% higher ( P < 0.0001) than the corresponding 1CMM [Formula: see text] and[Formula: see text] indexes: 2.81 ± 0.29 (SE) vs.[Formula: see text] = 4.27 ± 0.33 ml ⋅ min−1 ⋅ kg−1and [Formula: see text] = 11.67 ± 1.71 vs.[Formula: see text] = 8.68 ± 1.62 102ml ⋅ min−1 ⋅ kg−1per μU/ml. [Formula: see text] was not different from[Formula: see text] = 12.61 ± 2.13 102ml ⋅ min−1 ⋅ kg−1per μU/ml (nonsignificant), whereas [Formula: see text]was 60% lower ( P < 0.02). In conclusion, a new 2CMM has been presented that improves the accuracy of glucose effectiveness and insulin sensitivity estimates of the classic 1CMM from a standard IVGTT in normal humans.


PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0262584
Author(s):  
Hannah M. Kinsella ◽  
Laura D. Hostnik ◽  
Hailey A. Snyder ◽  
Sarah E. Mazur ◽  
Ahmed M. Kamr ◽  
...  

The equine neonate is considered to have impaired glucose tolerance due to delayed maturation of the pancreatic endocrine system. Few studies have investigated insulin sensitivity in newborn foals using dynamic testing methods. The objective of this study was to assess insulin sensitivity by comparing the insulin-modified frequently sampled intravenous glucose tolerance test (I-FSIGTT) between neonatal foals and adult horses. This study was performed on healthy neonatal foals (n = 12), 24 to 60 hours of age, and horses (n = 8), 3 to 14 years of age using dextrose (300 mg/kg IV) and insulin (0.02 IU/kg IV). Insulin sensitivity (SI), acute insulin response to glucose (AIRg), glucose effectiveness (Sg), and disposition index (DI) were calculated using minimal model analysis. Proxy measurements were calculated using fasting insulin and glucose concentrations. Nonparametric statistical methods were used for analysis and reported as median and interquartile range (IQR). SI was significantly higher in foals (18.3 L·min-1· μIU-1 [13.4–28.4]) compared to horses (0.9 L·min-1· μIU-1 [0.5–1.1]); (p < 0.0001). DI was higher in foals (12 × 103 [8 × 103−14 × 103]) compared to horses (4 × 102 [2 × 102−7 × 102]); (p < 0.0001). AIRg and Sg were not different between foals and horses. The modified insulin to glucose ratio (MIRG) was lower in foals (1.72 μIUinsulin2/10·L·mgglucose [1.43–2.68]) compared to horses (3.91 μIU insulin2/10·L·mgglucose [2.57–7.89]); (p = 0.009). The homeostasis model assessment of beta cell function (HOMA-BC%) was higher in horses (78.4% [43–116]) compared to foals (23.2% [17.8–42.2]); (p = 0.0096). Our results suggest that healthy neonatal foals are insulin sensitive in the first days of life, which contradicts current literature regarding the equine neonate. Newborn foals may be more insulin sensitive immediately after birth as an evolutionary adaptation to conserve energy during the transition to extrauterine life.


2020 ◽  
Vol 105 (5) ◽  
pp. e2061-e2068 ◽  
Author(s):  
Megan M Kelsey ◽  
Laura Pyle ◽  
Allison Hilkin ◽  
Cameron D Severn ◽  
Kristina Utzschneider ◽  
...  

Abstract Context Physiologic changes in glucose metabolism are well-described to occur during puberty. However, there are important gaps in understanding the interaction between obesity and the normal physiologic changes during puberty, as well as how these changes could contribute to the increased risk of comorbidities, such as type 2 diabetes and dyslipidemia, in youth with obesity. Objective The objective of this study was to compare longitudinal changes in insulin sensitivity (Si) and secretion during pubertal progression in youth with obesity versus those with normal weight. Design Longitudinal observational study evaluating youth from early puberty (Tanner [T]2-T3) until puberty completion (T5). Setting Pediatric academic hospital Clinical Translational Research Center. Participants Pubertal youth with normal weight (n = 47; 22 female, 25 male) and obesity (n = 37; 23 female, 14 male) Main Outcome Measures Si, insulin response (acute insulin response to glucose, AIRg) and disposition index (DI) by intravenous glucose tolerance test at baseline (T2-T3), T4, and T5 Results Youth with obesity had significantly lower Si and higher AIRg at each time point (P &lt; 0.001), but DI was similar between the groups. There were no group differences in trajectory of Si, AIRg or DI over time. Leptin, insulin-like growth factor-1, and obesity were most strongly associated with Si and AIRg at all time points. Conclusions Obesity significantly impacts Si during puberty, even at the earliest stages. However, in general, obese youth have adequate β-cell compensation for the significantly reduced Si of puberty. Future studies are needed to better predict the subset of youth who fail to maintain β-cell compensation during puberty.


1997 ◽  
Vol 273 (5) ◽  
pp. E1024-E1032 ◽  
Author(s):  
Paolo Vicini ◽  
Andrea Caumo ◽  
Claudio Cobelli

A two-compartment minimal model (2CMM) has been proposed [A. Caumo and C. Cobelli. Am. J. Physiol. 264 ( Endocrinol. Metab. 27): E829–E841, 1993] to describe intravenous glucose tolerance test (IVGTT) labeled (hereafter hot) glucose kinetics. This model, at variance with the one-compartment minimal model (1CMM), allows the estimation of a plausible profile of glucose production. The aim of this study is to show that the 2CMM also allows the assessment of insulin sensitivity ([Formula: see text]), glucose effectiveness ([Formula: see text]), and plasma clearance rate (PCR). The 2CMM was identified on stable-isotope IVGTTs performed in normal subjects ( n = 14). Results were (means ± SE) [Formula: see text] = 0.85 ± 0.14 ml ⋅ kg−1 ⋅ min−1, PCR = 2.02 ± 0.14 ml ⋅ kg−1 ⋅ min−1, and [Formula: see text] = 13.83 ± 2.54 × 10−2ml ⋅ kg−1 ⋅ min−1 ⋅ μU−1 ⋅ ml. The 1CMM was also identified; glucose effectiveness and insulin sensitivity indexes were [Formula: see text]V = 1.36 ± 0.08 ml ⋅ kg−1 ⋅ min−1and [Formula: see text] V = 12.98 ± 2.21 × 10−2ml ⋅ kg−1 ⋅ min−1 ⋅ μU−1 ⋅ ml, respectively, where V is the 1CMM glucose distribution volume.[Formula: see text]V was lower than PCR and higher than [Formula: see text] and did not correlate with either [ r = 0.45 (NS) and r = 0.50 (NS), respectively], whereas [Formula: see text]V was not different from and was correlated with[Formula: see text]( r = 0.95; P < 0.001).[Formula: see text] compares well ( r = 0.78; P < 0.001) with PCR normalized by the 2CMM total glucose distribution volume. In conclusion, the 2CMM is a powerful tool to assess glucose metabolism in vivo.


Sign in / Sign up

Export Citation Format

Share Document