A method of producing calibrated microtubules for air embolism studies

1981 ◽  
Vol 51 (2) ◽  
pp. 524-528 ◽  
Author(s):  
B. A. Hills ◽  
B. D. Butler

Utilizing the differential absorption techniques in conjunction with gas injection methods has enabled the production of calibrated microtubules with diameters ranging from 14 to 300 micron. Nitrogen was blended with CO2, the "diluent" gas, to produce the initial bubbles, while tris(hydroxymethyl)-aminomethane hydrochloride (THAM) was used as an absorbent to remove the diluent gas from the bubbles. Hence, the diameters of the initial bubbles were significantly reduced with only the inert gas remaining. The Coulter counter was used for immediate size monitoring of the microtubules. To verify the inertness of the absorbent medium, nine anesthetized dogs were infused with increasing amounts of the solution. In five of the animals plasma surface tension and pH (arterial) were measured, while in the remaining four arterial blood pressure, heart rate, breathing frequency, and pulmonary artery pressure was measured before, during, and after the injections. Changes in plasma surface tension and pH were minimal while acceptable physiological values were recorded, all of which were in agreement with previous investigations. Differential absorption techniques provided a reliable means for producing calibrated micro-bubbles for air embolism studies.

1982 ◽  
Vol 52 (1) ◽  
pp. 119-123 ◽  
Author(s):  
B. A. Hills ◽  
R. E. Barrow

The relationship between surface tension and surface area has been measured on each of three common pulmonary surfactants - dipalmitoyl lecithin (DPL), dipalmitoyl phosphatidylethanolamine, and sphyngomyelin-under simultaneously simulated physiological conditions. These are selected to simulate the state of any surfactant that has migrated onto the surface of venous bubbles filtered by the pulmonary vasculature. It is concluded that, in the absence of shunt vessels, only DPL could reduce surface tension enough to allow pulmonary gas emboli to escape into arterial blood and then only after compression. This finding is discussed in relation to the delay in any appearance of bubbles in arterial blood and the possible facilitation of the release of asymptomatic lung bubbles by recompression therapy. The suggestion is made to reconsider stopping recompression of a subject with peripheral decompression sickness (the bends) at the depth of relief rather than risk releasing pulmonary gas emboli by further recompression. It is also demonstrated how the introduction of 1-min stops into compression can avoid surface tension falling to the low values at which it is theoretically possible for venous bubbles to escape into arterial blood during pulmonary hypertension.


Perfusion ◽  
1986 ◽  
Vol 1 (3) ◽  
pp. 187-191 ◽  
Author(s):  
BD Butler ◽  
M. Kurusz ◽  
VR Conti

Plasma samples from patients undergoing open-heart surgery were obtained at the end of cardiopulmonary bypass for surface tension analysis. The samples were measured with a Du Nouy tensiometer for true static surface tension. The surface tension values from 40 patients were analysed and correlated with plasma free haemoglobin levels, cardiopulmonary bypass time and oxygenator type. The mean surface tension value for the plasma samples was 49·96 ± 2·98 dynes/cm. No statistical correlation was found between the surface tension and the three variables. Surface tension phenomena have important implications in the removal of gaseous microemboli by screen filtration of arterial blood as it is applied to the bubble point concept. Another aspect of surface tension involves the concept of capillarity which considers the forces tending to push a bubble through a blood vessel thus preventing the obstruction of blood flow. The results of this study provide actual values of plasma surface tension from patients undergoing cardiopulmonary bypass.


1986 ◽  
Vol 61 (6) ◽  
pp. 2095-2101 ◽  
Author(s):  
T. C. Lloyd

Anesthetized open-chest dogs on cardiopulmonary bypass were used to test the hypothesis that breathing reflexly responds to distension of the left-heart chambers. Bypass perfusion withdrew systemic flow from the right atrium and returned it to the aorta after gas exchange. Ventricles were fibrillated. The left heart was isolated by tying all pulmonary veins, and it was perfused separately at low flow admitted through one pulmonary vein and withdrawn from the ventricle. Left-heart pressure was intermittently raised abruptly from a nominal base line of 0 by partial occlusion of outflow. Pressures from approximately 10 to 50 cmH2O caused proportional increases in breathing frequency and decreases in expiratory and inspiratory times. Changes occurred immediately, reached a plateau within approximately 20 s, and were sustained for periods of observation as long as 3 min. Recovery to base line followed stimulus removal. Vagal cooling to 8 degrees C prevented responses, but autonomic ganglion blockade with hexamethonium had no effect. I conclude that breathing may be stimulated by left-heart distension and that this is mediated by large myelinated vagal afferents.


2018 ◽  
Vol 125 (6) ◽  
pp. 1749-1759 ◽  
Author(s):  
Ashley M. Loeven ◽  
Candace N. Receno ◽  
Caitlin M. Cunningham ◽  
Lara R. DeRuisseau

Isoflurane (ISO) is a commonly used anesthetic that offers rapid recovery for laboratory animal research. Initial studies indicated no difference in arterial Pco2 ([Formula: see text]) or pH between conscious (NO ISO) and 1% ISO-exposed CD-1 mice. Our laboratory investigated whether arterial blood sampling with 1% ISO is a suitable alternative to NO ISO sampling for monitoring ventilation in a commonly studied mouse strain. We hypothesized similar blood chemistry, breathing patterns, and cardiovascular responses with NO ISO and 1% ISO. C57BL/6J mice underwent unrestrained barometric plethysmography to quantify the pattern of breathing. Mice exposed to hypoxic and hypercapnic gas under 1% ISO displayed blunted responses; with air, there were no breathing differences. Blood pressure and heart rate were not different between NO ISO and 1% ISO-exposed mice breathing air. Oxygen saturation was not different between groups receiving 2% ISO, 1% ISO, or air. Breathing frequency stabilized at ~11 min of 1% ISO following 2% ISO exposure, suggesting that 11 min is the optimal time for a sample in C57BL/6J mice. Blood samples at 1% ISO and NO ISO revealed no differences in blood pH and [Formula: see text] in C57BL/6J mice. Overall, this method reveals similar arterial blood sampling values in awake and 1% ISO CD-1 and C57BL/6J mice exposed to air. Although this protocol may be appropriate in other mouse strains when a conscious sample is not feasible, caution is warranted first to identify breathing frequency responses at 1% ISO to tailor the protocol. NEW & NOTEWORTHY Conscious arterial blood sampling is influenced by extraneous factors and is a challenging method due to the small size of mice. Through a series of experiments, we show that arterial blood sampling with 1% isoflurane (ISO) is an alternative to awake sampling in C57BL/6J and CD-1 male mice breathing air. Monitoring breathing frequency during 1% ISO is important to the protocol and should be closely followed to confirm adequate recovery after the catheter implantation.


1997 ◽  
Vol 272 (3) ◽  
pp. R766-R775 ◽  
Author(s):  
M. Horackova ◽  
J. A. Armour

To determine whether angiotensin II (ANG II) affects cardiac performance via neurons in intrathoracic cardiac ganglia, studies were performed on anesthetized dogs. To exclude possible vascular regulatory effects of ANG II, experiments were also performed using long-term cultures of adult guinea pig ventricular cardiomyocytes with or without intrathoracic neurons. 1) In in situ experiments in 10 anesthetized dogs, cardiac augmentation occurred when ANG II (10 microl or 0.1 ml; 10-100 microM) was administered into limited loci within acutely decentralized stellate or middle cervical ganglia that were neurally connected to, but not those disconnected from, the heart. In another 18 dogs, ANG II increased intrinsic cardiac neuronal activity when administered adjacent to such neurons or into their local arterial blood supply. Ventricular ionotropic effects elicited by ANG II were eliminated by timolol, whereas increases in intrinsic cardiac neuronal activity were not affected. Effects elicited by ANG II were eliminated by administration of a selective AT1 receptor antagonist (losartan) but not by a selective AT2 receptor antagonist (PD-123319). 2) In in vitro experiments, ANG II (100 nM) induced positive chronotropic effects on cultured adult guinea pig cardiomyocytes innervated with adult extrinsic or intrinsic cardiac neurons, but not those cultured without neurons. The frequency of calcium inward current (Ca(i)) transients (recorded by fura 2 fluorescence) increased in innervated cocultures but not in the noninnervated cardiomyocyte cultures; however, the amplitude of Ca(i) transients was not affected by ANG II in cultures or in freshly isolated adult guinea pig cardiomyocytes. ANG II-induced effects in cocultures were blocked by losartan but not PD-123319 or timolol. Thus 1) ANG II-sensitive neurons exist in intrathoracic extracardiac and intrinsic cardiac ganglia; 2) these neurons possess AT1 receptors; and 3) these neurons appear to act directly and indirectly via adrenergic neurons to enhance cardiomyocyte function.


1961 ◽  
Vol 200 (6) ◽  
pp. 1169-1176 ◽  
Author(s):  
William E. Huckabee

Veno-arterial differences of pyruvate and lactate across the myocardium in chloralose-anesthetized dogs were very variable; in any one animal they changed continually with time despite constant blood flow and arterial blood concentrations. There was a systematic tendency of v-a lactate to vary with v-a pyruvate, as expressed in the calculated "Δ excess lactate," which remained nearly constant (or, if blood flow changed, bore a constant ratio to (a-v)O2). No change in Δ excess lactate from control values occurred in nonhypoxic experiments despite marked changes in v-a differences, arterial blood composition, and coronary flow. Cardiac Δ excess lactate became positive in most animals breathing 10% O2 in N2; output of excess lactate was also observed in all those in which moderate muscular exercise was induced. This anaerobic metabolism, or change in the relationship between pyruvate and lactate exchanges, was interpreted as an indication that O2 delivery response was not adequate to meet cardiac tissue requirements during such mild stresses when judged by the standards of adequacy of the basal state.


2020 ◽  
Vol 48 ◽  
Author(s):  
Bárbara Silva Correia ◽  
Eduardo Raposo Monteiro ◽  
João Victor Barbieri Ferronatto ◽  
Luciana Branquinho Queiroga ◽  
José Ricardo Herrera Becerra

Background: Arterial blood pressure is one of the most commonly variables monitored during anesthetic procedures in veterinary patients. The most reliable method for measuring arterial blood pressure in dogs and cats is the direct (invasive) method. However, the oscillometric method is less complex and more practical for clinical routine in small animals. Nevertheless, oscillometric monitors present great variability in accuracy. The present study aimed to determine the accuracy of the Delta Life DL 1000 oscillometric monitor for measurement of systolic, mean and diastolic blood pressures (SAP, MAP and DAP, respectively) in anesthetized dogs of different weight ranges.Materials, Methods & Results: This study was approved by the Institutional Ethics Committee of Animal Use. Fifteen female dogs of different breeds, weighing 11.6 ± 10.0 kg and with a mean age of 48 ± 51 months were used. All animals were scheduled for elective surgery under general anesthesia in the Institution Veterinary Hospital. Dogs were anesthetized with morphine, propofol and isoflurane and had one 20 or 22 gauge catheter introduced into the dorsal pedal artery for continuous, invasive monitoring of SAP, MAP and DAP. A blood pressure cuff was positioned over the middle third of the radius and connected to Delta Life DL 1000 monitor. Oscillometric readings of SAP, MAP and DAP were registered every 5 minutes, and invasive values were simultaneously recorded. Values obtained with both methods were compared (invasive versus oscillometric) by use of the Bland Altman method to determine the bias, standard deviation of bias and 95% limits of agreement. The percentages of errors between the methods within 10 mmHg and within 20 mmHg were calculated. The results obtained were compared with the criteria from the American College of Veterinary Internal Medicine (ACVIM) for validation of indirect methods of arterial blood pressure measurement. Data were stratified into two groups according to the weight: < 10 kg (Group 1; n = 9); and ≥ 10 kg (Group 2; n = 6). In Group 1, 119 paired measurements were obtained, four of which classified as hypotension (SAP < 90 mmHg), 98 as normotension (SAP from 90 to 140mmHg) and 17 as hypertension (SAP > 140 mmHg). Bias (± SD) values in Group 1 were as follows: SAP, 5.2 ± 18.1 mmHg; MAP, -3.4 ± 17.2 mmHg; and DAP, 12.0 ± 17.5 mmHg. The percentages of errors within 10 mmHg were 40.3% for SAP; 45.4% for MAP and 28.6% for DAP. The percentages of errors within 20 mmHg were 72.3% for SAP, 84.0% for MAP and 68.1% for DAP. In Group 2, 66 paired measurements were obtained, nine of which classified as hypotension, 56 as normotension and one as hypertension. Bias (± SD) in Group 2 were as follows: SAP, 13.6 ± 14.3 mmHg; MAP, -1.1 ± 13.5 mmHg; and DAP, 8.2 ± 16.0 mmHg. The percentages of errors within 10 mmHg were 33.3% for SAP, 77.3% for MAP and 33.3% for DAP. The percentages of errors within 20 mmHg were 65.1% for SAP, 92.4% for MAP and 83.4% for DAP.Discussion: Based on the results of this study and reference criteria from the ACVIM, the Delta Life DL 1000 monitor had a poor accuracy for SAP, MAP and DAP and did not meet the criteria from the ACVIM in anesthetized dogs under 10 kg. Measurements of MAP in dogs ≥ 10 kg met the ACVIM criteria, but measurements of SAP and DAP did not. Based on the findings in this study, the DL 1000 oscillometric monitor is not recommended for blood pressure measurement in anesthetized dogs < 10 kg. In dogs ≥ 10 kg, measurements of MAP yielded acceptable values, but SAP and DAP measurements did not.


1983 ◽  
Vol 58 (3) ◽  
pp. 356-361 ◽  
Author(s):  
Michael P. McIlhany ◽  
Lydia M. Johns ◽  
Thomas Leipzig ◽  
Nicholas J. Patronas ◽  
Frederick D. Brown ◽  
...  

✓ Partially purified protein from washed and artificially hemolyzed erythrocytes, known to cause significant contractions of isolated canine cerebral vessels in vitro, was injected into the cisterna magna of intact anesthetized dogs. Cerebral blood flow, measured by the xenon-133 washout technique, decreased from a control value of 49.5 ± 1.17 ml/100 gm/min to an experimental value of 34.1 ± 1.65 ml/100 gm/min at 2 hours. Cerebral vascular resistance rose from a control value of 2.05 ± 0.17 PRU (peripheral resistance units) to an experimental value of 2.91 ± 0.25 PRU at 2 hours. Mean arterial blood pressure, heart rate, intracranial pressure, and cerebral perfusion pressure remained stable. Cardiac output also fell significantly (in 2-hour control animals it was 2.89 ± 0.37 liter/min, and in 2-hour experimental animals 1.43 ± 0.13 liter/min) and peripheral vascular resistance rose. These changes were evident by 10 minutes after the cisternal injection of the hemolysate protein, and remained for the duration of the 2-hour monitoring period. Serial vertebrobasilar angiograms demonstrated marked narrowing of the intracranial basilar artery when compared to control values. The narrowing persisted for several days in most animals, and tended to increase with time. Relaxation occurred by the 10th through the 14th day. The authors conclude that this experimental preparation may be a useful model for both in vitro and in vivo investigation of chronic cerebral vasospasm.


1998 ◽  
Vol 34 (1) ◽  
pp. 84-91 ◽  
Author(s):  
A Bufalari ◽  
SM Miller ◽  
C Giannoni ◽  
CE Short

Cardiovascular, pulmonary, and quantitative electroencephalographic parameters were assessed in 12 anesthetized dogs to determine the compatibility of the injectable anesthetic propofol with halothane and isoflurane. No cases of apnea were observed during induction of anesthesia. An adequate level of anesthesia was established in each protocol as judged by both the lack of response to mechanical noxious stimuli (i.e., tail clamping) and evidence of reduction in total amplitude of brain wave activity. The initial propofol-mediated decrease in arterial blood pressure continued during either halothane (52.4%) or isoflurane (38%) anesthesia without a simultaneous increase in heart rate. The results of this study suggest that propofol, in combination with inhalant agents, can be used effectively and safely for canine anesthesia in veterinary practice.