scholarly journals CFD Analysis of Energy Separation in Ranque-Hilsch Vortex Tube at Cryogenic Temperature

2013 ◽  
Vol 2013 ◽  
pp. 1-14 ◽  
Author(s):  
T. Dutta ◽  
K. P. Sinhamahapatra ◽  
S. S. Bandyopadhyay

Study of the energy separation phenomenon in vortex tube (VT) at cryogenic temperature (temperature range below 123 K) has become important because of the potential application of VT as in-flight air separator in air breathing propulsion. In the present study, a CFD model is used to simulate the energy separation phenomenon in VT with gaseous air at cryogenic temperature as working fluid. Energy separation at cryogenic temperature is found to be considerably less than that obtained at normal atmospheric temperature due to lower values of inlet enthalpy and velocity. Transfer of tangential shear work from inner to outer fluid layers is found to be the cause of energy separation. A parametric sensitivity analysis is carried out in order to optimize the energy separation at cryogenic temperature. Also, rates of energy transfer in the form of sensible heat and shear work in radial and axial directions are calculated to investigate the possible explanation of the variation of the hot and cold outlet temperatures with respect to various geometric and physical input parameters.

2013 ◽  
Vol 17 (4) ◽  
pp. 1079-1092 ◽  
Author(s):  
Mahyar Kargaran ◽  
A. Arabkoohsar ◽  
S.J. Hagighat-Hosini ◽  
V. Farzaneh-Kord ◽  
Mahmood Farzaneh-Gord

Vortex tube is a simple device without a moving part which is capable of separating hot and cold gas streams from a higher pressure inlet gas stream. The mechanism of energy separation has been investigated by several scientists and second law approach has emerged as an important tool for optimizing the vortex tube performance. Here, a thermodynamic model has been used to investigate vortex tube energy separation. Further, a method has been proposed for optimizing the vortex tube based on the rate of entropy generation obtained from experiments. Also, an experimental study has been carried out to investigate the effects of the hot tube length and cold orifice diameter on entropy generation within a vortex tube with natural gas as working fluid. A comparison has been made between air and natural gas as working fluids. The results show that the longest tube generates lowest entropy for NG. For air, it is middle tube which generates lowest entropy. Integration of entropy generation for all available cold mass fractions unveiled that an optimized value for hot tube length and cold orifice diameter is exist.


Author(s):  
Hossein Khazaei ◽  
Iman Mirzaii ◽  
Ali reza Teymourtash

In this paper, energy separation effect in a vortex tube has been investigated using a CFD model. The numerical simulation has been done due to the complex structure of flow. The governing equations have been solved by FLUENT™ code in 2D compressible and turbulent model. The effects of geometrical parameters have been investigated. The results have shown that the hot outlet size and its shape, does not affect the energy distribution in vortex tube and very small diameter will decrease the temperature separation.


2016 ◽  
Vol 138 (8) ◽  
Author(s):  
Gaurav Sharma ◽  
Sumana Ghosh ◽  
Srinibas Karmakar

In the present work, a computational fluid dynamic (CFD) simulation has been performed to investigate single and two-phase vortex tube. Air in compressed form and partially condensed phase are used as working fluid, respectively. Simulation has been carried out using commercial CFD software package fluent 6.3.26. A detailed study has been performed to generate the profiles of velocity, pressure, and pathlines. These profiles provide an insight on how the process of energy separation as well as the flow field in the vortex tube gets affected on introduction of a liquid phase. The result shows that in case of cryogenic vortex tube, the flow reversal takes place closer to wall due to presence of a very thin wall adhering liquid film, while, in single-phase flow vortex tube, flow reversal is observed at the central portion. The model also predicts that presence of recirculation zone near warm end diminishes the refrigeration effect of vortex tube for two-phase flow.


Author(s):  
Younghyeon Kim ◽  
Jinwon Yun ◽  
Sangseok Yu

Due to the global warming, climate treaty regulations and credits have been enhanced. As a result, the Carbon Capture & Storage (CCS) technologies have been emerged. In this study, it is presented that is separating the CO2 from Air by vortex generator. The vortex tube is a device to separate inlet gases to hotter and colder mixture than inlet by energy separation technology. In this study, the vortex tube is applied to CO2 gas separation from air that is investigated under atmospheric temperature. Prior to feasibility experiment, transient response shows that the temperature separation is settled down in 3000 seconds. Experimental parameters of gas separation are pressures and concentrations of CO2 that is mixed with air. Results show that CO2 gas separation is proportional to operating temperature. The percentage of CO2 gas separation is 7.4 % at 3barg and cold mass fraction of 0.6. The gas separation is also affected by inlet CO2 concentration.


2012 ◽  
Vol 16 (1) ◽  
pp. 151-166 ◽  
Author(s):  
Nader Pourmahmoud ◽  
Hassan Zadeh ◽  
Omid Moutaby ◽  
Abdolreza Bramo

In this article computational fluid dynamics (CFD) analysis of a three-dimensional steady state compressible and turbulent flow has been carried out through a vortex tube. The numerical models use the k-? turbulence model to simulate an axisymmetric computational domain along with periodic boundary conditions. The present research has focused on the energy separation and flow field behavior of a vortex tube by utilizing both straight and helical nozzles. Three kinds of nozzles set include of 3 and 6 straight and 3 helical nozzles have been investigated and their principal effects as cold temperature difference was compared. The studied vortex tubes dimensions are kept the same for all models. The numerical values of hot and cold outlet temperature differences indicate the considerable operating role of helical nozzles, even a few numbers of that in comparing with straight nozzles. The results showed that this type of nozzles causes to form higher swirl velocity in the vortex chamber than the straight one. To be presented numerical results in this paper are validated by both available experimental data and flow characteristics such as stagnation point situation and the location of maximum wall temperature as two important facts. These comparisons showed reasonable agreement.


2019 ◽  
pp. 418-418
Author(s):  
Lizan Zangana ◽  
Ramzi Barwari

In this manuscript, both experimental and numerical investigations have been carried out to study the mechanism of separation energy and flow phenomena in the counter flow vortex tube. This manuscript presents a complete comparison between the experimental investigation and CFD analysis. The experimental model was manufactured with (total length of 104 mm and the inner diameter of 8 mm, and made of cast iron) tested under different inlet pressures (4, 5 and 6 bar). The thermal performance has been studied for hot and cold outlet temperature as a function of mass fraction ? (0.3- 0.8). Three-dimensional numerical modeling using the k-? model used with code (Fluent 6.3.26). Two types of velocity components are studied (axial and swirl). The results show any increase in both cold mass fraction and inlet pressure caused to increase ?Tc, and the maximum ?Tc value occurs at P = 6 bar. The coefficient of performance (COP) of two important factors in the vortex tube which are a heat pump and a refrigerator have been evaluated, which ranged from 0.25 to 0.74. A different axial location (Z/L = 0.2, 0.5, and 0.8) was modeled to evaluate swirl velocity and radial profiles, where the swirl velocity has the highest value. The maximum axial velocity is 93, where it occurs at the tube axis close to the inlet exit (Z/L=0.2). The results showed a good agreement for experimental and numerical analysis.


2018 ◽  
Vol 7 (2.20) ◽  
pp. 250
Author(s):  
Banoth Mohan ◽  
V Ashok Kumar

A device may be a device worked for the sensible heat exchange beginning with one liquid then onto the attendant, paying very little reference to whether or not the liquids square measure isolates by a powerful divider in order that they ne'er mix, or the liquids square measure particularly in touch. reliably get some data concerning in device progression is creating to form productive, traditionalist and stinting heat exchangers, where for the duration of the planet. Strengthening the function for this alteration wants associate degree association. In most up-to-date 5 years coaxial tube heat exchangers use unnatural convection to cut down the temperature of a operating liquid whereas raising the temperature of the cooling medium. The motivation driving this paper is to utilize ANSYS FLUENT12.1 programming and hand counts to interrupt down the temperature drops as a neighborhood of each straight speed and delta temperature and the way each modification with the opposite. every gleam money dealer show was worked in steps and examined in transit till the purpose that the instant that each parallel stream and counter stream heat money dealer models were created. The outcomes were thought of between every model and among parallel and counter stream with fouled funneling. Turbulent stream was conjointly impecunious down amidst the distinction within the shine exchangers to choose its impact on heat exchange. whereas clearly the fouled heat money dealer had a lower execution and during this manner cooled the operating liquid less, the execution of the counter heat money dealer out of the blue of the parallel heat money dealer.


2021 ◽  
Vol 850 (1) ◽  
pp. 012024
Author(s):  
Ravi Kant Singh ◽  
Achintya Kumar Pramanick ◽  
Subhas Chandra Rana

Abstract The present study intends to improve the performance of the Ranque-Hilsch counter flow vortex tube, analysed using computational fluid dynamics. In the axisymmetric 3-D, steady-state, compressible, and turbulent flow vortex tube, the air has been used as the working fluid. The ANSYS17.1 FLUENT software has been used with the standard º-ε turbulent model for different mass fraction of cold fluid and inlet pressure in the numerical simulation and validated with the experimental results. It is observed from the study that as the inlet chambers number increases from 1 to 2, there is a decrease of 7.8 % in the cold exit temperature of the vortex tube. However, insulating the double chamber vortex tube leads to a further reduction of 4.2% in the cold exit temperature. Therefore, it indicates that the overall decline in the cold exit temperature from one chamber non-insulated vortex tube to double chamber insulated vortex tube is 9.6%. In terms of cold exit temperature, it can be concluded that using a double inlet chamber vortex tube with insulation yields the optimum results.


Sign in / Sign up

Export Citation Format

Share Document