scholarly journals Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis

2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Kenichi Watanabe ◽  
Masayuki Kyomoto ◽  
Kenichi Saiga ◽  
Shuji Taketomi ◽  
Hiroshi Inui ◽  
...  

The wear and creep deformation resistances of polymeric orthopedic bearing materials are both important for extending their longevity. In this study, we evaluated the wear and creep deformation resistances, including backside damage, of different polyethylene (PE) materials, namely, conventional PE, cross-linked PE (CLPE), and poly(2-methacryloyloxyethyl phosphorylcholine)- (PMPC-) grafted CLPE, through wear tests and finite element analysis. The gravimetric and volumetric degrees of wear of disks (3 or 6 mm in thickness) of these materials against a cobalt-chromium-molybdenum alloy pin were examined using a multidirectional pin-on-disk tester. Cross-linking and PMPC grafting decreased the gravimetric wear of the PE disks significantly. The volumetric wear at the bearing surface and the volumetric penetration in the backside of the 3-mm thick PE disk were higher than those of the 6-mm thick PE disk, regardless of the bearing material. The geometrical changes induced in the PE disks consisted of creep, because the calculated internal von Mises stress at the bearing side of all disks and that at the backside of the 3-mm thick disks exceeded their actual yield strengths. A highly hydrated bearing surface layer, formed by PMPC grafting, and a cross-linking-strengthened substrate of adequate thickness are essential for increasing the wear and creep deformation resistances.

2021 ◽  
Vol 11 (6) ◽  
pp. 2547 ◽  
Author(s):  
Carlo Prati ◽  
João Paulo Mendes Tribst ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Alexandre Luiz Souto Borges ◽  
Maurizio Ventre ◽  
...  

The aim of the present investigation was to calculate the stress distribution generated in the root dentine canal during mechanical rotation of five different NiTi endodontic instruments by means of a finite element analysis (FEA). Two conventional alloy NiTi instruments F360 25/04 and F6 Skytaper 25/06, in comparison to three heat treated alloys NiTI Hyflex CM 25/04, Protaper Next 25/06 and One Curve 25/06 were considered and analyzed. The instruments’ flexibility (reaction force) and geometrical features (cross section, conicity) were previously investigated. For each instrument, dentine root canals with two different elastic moduli(18 and 42 GPa) were simulated with defined apical ratios. Ten different CAD instrument models were created and their mechanical behaviors were analyzed by a 3D-FEA. Static structural analyses were performed with a non-failure condition, since a linear elastic behavior was assumed for all components. All the instruments generated a stress area concentration in correspondence to the root canal curvature at approx. 7 mm from the apex. The maximum values were found when instruments were analyzed in the highest elastic modulus dentine canal. Strain and von Mises stress patterns showed a higher concentration in the first part of curved radius of all the instruments. Conventional Ni-Ti endodontic instruments demonstrated higher stress magnitudes, regardless of the conicity of 4% and 6%, and they showed the highest von Mises stress values in sound, as well as in mineralized dentine canals. Heat-treated endodontic instruments with higher flexibility values showed a reduced stress concentration map. Hyflex CM 25/04 displayed the lowest von Mises stress values of, respectively, 35.73 and 44.30 GPa for sound and mineralized dentine. The mechanical behavior of all rotary endodontic instruments was influenced by the different elastic moduli and by the dentine canal rigidity.


Author(s):  
Osezua Obehi Ibhadode ◽  
Ishaya Musa Dagwa ◽  
Akii Okonigbon Akhaehomen Ibhadode

Calibration curves of a multi-component dynamometer is of essence in machining operations in a lathe machine as they serve to provide values of force and stress components for cutting tool development and optimization. In this study, finite element analysis has been used to obtain the deflection and stress response of a two component cutting tool lathe dynamometer, for turning operation, when the cutting tool is subjected to cutting and thrust forces from 98.1N to 686.7N (10 to 70kg-wts), at intervals of 98.1N(10kg-wt). By obtaining the governing equation, modeling the dynamometer assembly, defining boundary conditions, generating the assembly mesh, and simulating in Inventor Professional; horizontal and vertical components of deflection by the dynamometer were read off for three different loading scenarios. For these three loading scenarios, calibration plots by experiment compared with plots obtained from simulation by finite element analysis gave accuracies of 79%, 95%, 84% and 36%, 57%, 63% for vertical and horizontal deflections respectively. Also, plots of horizontal and vertical components of Von Mises stress against applied forces were obtained.


2016 ◽  
Vol 138 (3) ◽  
Author(s):  
Mohammad Shafinul Haque ◽  
Calvin Maurice Stewart

The creep deformation and damage evolution of nickel base superalloy (Waspaloy) at 700 °C are studied using the classic Kachanov–Rabotnov (KR) and a recently developed Sin-hyperbolic (Sinh) model. Uniaxial creep deformation and Bridgman rupture data collected from literature are used to determine the model constants and to compare the KR and the Sinh solutions. Finite-element (FE) simulations on a single eight-node element are conducted to validate the accuracy of the FE code. It is observed that KR cannot predict the creep deformation, damage, and rupture life of nickel base superalloys accurately using one set of constants for all the stress levels. The Sinh model exhibits a superior ability to predict the creep behavior using one set of constants for all the stress levels. Finite-element analysis (FEA) on 3D Bridgman notched Waspaloy specimen using the Sinh model is conducted. The results show that the Sinh model when combined with a representative stress equation and calibrated with experimental data can accurately predict the “notch effect” observed in the rupture life of notched specimen. Contour plots of damage evolution and stress redistribution are presented. It is demonstrated that the Sinh model is less stress sensitive, produces unconditional critical damage equal to unity at rupture, exhibits a more realistic damage distribution around the crack tip, and offers better crack growth analysis than KR.


2018 ◽  
Vol 25 (2) ◽  
pp. 10
Author(s):  
Medardo Alexander Arenas-Chavarria ◽  
Samuel David Giraldo-Gómez ◽  
Federico Latorre-Correa ◽  
Junes Abdul Villarraga-Ossa

Aim: The purpose of this research was to evaluate the behavior of the system locator settings associated with distal extension removable partial denture lower (PPR) by finite element analysis (FEA). Materials and Methods: A Class II Kennedy 3D model using a CAD software Solid Works 2010 (SolidWorks Corp., Concord, MA, USA), and subsequently processed and analyzed by ANSYS Software version Model 14. One (1) was designed implant Tapered Screw -Vent® (ref TSVB10 Zimmer Dental-Carlsbad,CA,USA.) length x 10mm diameter 3.7mm with a 3.5mm platform, internal hexagon with its respective screw fixation; this was located at the tooth 37 as a rear pillar of a PPR, whose major connector was a lingual bar casting (alloy cobalt chromium), based combined (metal/ acrylic) with teeth to replace (37, 36 and 35). Efforts were evaluated von Mises in a 400N load. This analysis allowed assessing the performance of various prosthetic structures modeled and generated effects on bone-implant interface. Results: Differences between the values von Mises in all structures and loads were observed before there was no permanent deformation in any of them. Structures such as bone showed in normal values microstrain. Conclusions: The behavior of the PPRimplant connection, showed a favorable distribution efforts by using a PPR, subjecting it to load in the vertical direction.


2021 ◽  
Vol 4 (2) ◽  
Author(s):  
Mubni Nazar ◽  
Anggito Pringgo Tetuko ◽  
Djuhana Djuhana

Penelitian ini dilakukan untuk meningkatkan koefisien daya yang maksimal. Salah satunya dengan mengunakan kualitas sudu yang baik. Untuk mengoptimalkan fungsi turbin angin penulis menggunakan material sudu pada turbin angin dengan menggunakan Acrylonitrine Butadine Styrene (ABS). Oleh karena itu pada penelitian ini metode yang digunakan adalah metode Finite Element Analysis Simulasi yang dipilih adalah dynamic. Penelitian ini adalah pengujian kekuatan sudu turbin angin horizontal dengan variasi kecepatan angin 10 – 20 m/s ditinjau dari von mises stress dan displacement. Dari hasil simulasi kecepatan angin memiiki pengaruh terhadap distribusi stress dan displacement. Material yang digunakan masih berada di bawah batas kekuatan material, semakin besar gaya yang diberikan semakin besar nilai stress dan displacement. Pada hasil simulasi didapatkan nilai stress minimum 5.8 Pa stress maksimum 22.94 Sedangkan dalam pengujian displacement dihasilkan nilai minimum 1.27 m displacement maksimum 4.99 m.


Author(s):  
Jifeng Wang ◽  
Qubo Li ◽  
Norbert Mu¨ller

A mechanical and optimal analyses procedure is developed to assess the stresses and deformations of Novel Wound Composite Axial-Impeller under loading conditions particular to centrifuge. This procedure is based on an analytical method and Finite Element Analysis (FEA, commercial software ANSYS) results. A low-cost, light-weight, high-performance, composite turbomachinery impeller from differently designed patterns will be evaluated. Such impellers can economically enable refrigeration plants using water as a refrigerant (R718). To create different complex patterns of impellers, MATLAB is used for creating the geometry of impellers, and CAD software UG is used to build three-dimensional impeller models. Available loading conditions are: radial body force due to high speed rotation about the cylindrical axis and fluid forces on each blade. Two-dimensional plane stress and three-dimensional stress finite element analysis are carried out using ANSYS to validate these analytical mechanical equations. The von Mises stress is investigated, and maximum stress and Tsai-Wu failure criteria are applied for composite material failure, and they generally show good agreement.


Author(s):  
Z Yi ◽  
WZ Fu ◽  
MZ Li

In order to obtain a higher pressure capacity for the high-pressure die with a larger sample cavity, two types of two-layer split dies with a round cylinder and a quadrate cylinder were designed based on the conventional belt-type die. Finite element analysis was performed to investigate the stress distributions and pressure capacities of the high-pressure dies using a derived Mohr–Coulomb criterion and the von Mises criterion for the cylinder and supporting rings, respectively. As predicted by the finite element analysis results, in the two-layer split dies with a round cylinder, the stress state of the cylinder can be only slightly improved; and the von Mises stress of the first layer supporting ring can be hardly decreased. However, in the two-layer split dies with a quadrate cylinder and sample cavity, the stress state of the cylinder can be remarkably improved. Simultaneously, the von Mises stress of the supporting rings, especially for the first-layer supporting ring, can be also effectively decreased. The pressure capacities of the two-layer split dies with a round cylinder and a quadrate cylinder are 16.5% and 63.9% higher with respect to the conventional belt-type die.


Author(s):  
Nazrul Islam ◽  
Tasnim Hassan

Abstract This study evaluates creep-fatigue damage in the modified Grade 91 thick-cylinder tested by Japan Atomic Energy Agency (JAEA), to understand the failure mechanism of critical components of Fast Reactor nuclear plants. As modified Grade 91 demonstrated creep-fatigue interaction induced failure mechanisms, finite element analysis of high-temperature components will require a unified constitutive model (UCM) that can simulate various creep-fatigue responses with reasonable accuracy. Hence, a UCM coupled with various advanced modeling features including the continuum damage modeling features is investigated to demonstrate their predictability of the fatigue, creep and creep-fatigue responses of the modified Grade 91 steel. The modified UCM is implemented into ABAQUS for analysis of creep deformation in the thick cylinder benchmark problem. Finite element analysis results are presented to demonstrate how the thermal cycling influences the creep-deformation of this high-temperature component. It is also demonstrated how thermal cycling’s influence on fatigue life can be determined based on the damage variable incorporated in the UCM.


2019 ◽  
Vol 10 (5) ◽  
pp. 678-691
Author(s):  
Intan Najwa Humaira Mohamed Haneef ◽  
Norhashimah Shaffiar ◽  
Yose Fachmi Buys ◽  
Abdul Malek Abd. Hamid

Purpose The internal fixation plate of bone fractures by using polylactic acid (PLA) has attracted the attention of many researchers, as it is biodegradable and biocompatible to the human body. However, its brittleness has led to implant fracture. On the contrary, polypropylene carbonate (PPC), which is also biodegradable and biocompatible, has an excellent elongation at break. The purpose of this paper is to compare the PLA fixation plate with the new fixation plate made up of PLA/PPC blends by using finite element analysis (FEA). Design/methodology/approach The mandible bone from CT data set and fixation plate was designed by using the MIMICS, Amira and Solidworks softwares. Abaqus software was used for FEA of PLA/PPC fixation plate applied on the fractured mandible bone. A model of mandibular bone with a fracture in the body was subjected to incisor load. The analysis was run to determine the von Mises stress, elongation of the fixation plate and the displacement of the fractured gap of PLA/PPC blends fixation plate. Findings The von Mises stress predicted that all the blend compositions were safe to be used as a fixation plate since the stress values were less than the yield strength. In addition, the stress value of the fixation plate was gradually decreased up to 20 percent when the amount of PPC increased to 30 percent. This indicates that the stress shielding effect was successfully reduced. The elongation of the fixation plate was gradually increased from 11.54 to 12.55 µm as the amount of PPC in the blends increased from 0 to 30 percent, thereby illustrating that the flexibility of the fixation plate was improved by the addition of PPC. Finally, the measured displacement of the fractured gap for all compositions of PLA/PPC blends fixation plate is less than 150 µm, which proves the likely success of fracture fixation by using the PLA/PPC blends. Research limitations/implications An optimum solution of PLA/PPC blends and another new material such as compatibilizer need to be introduced in the blends in order to improve the performance of PLA/PPC blends as a new material for a fixation plate. Besides, by using the same method of producing PLA/PPC blends, longer durations for in vitro degradation of PLA/PPC blends are essential to further understand the degradation behavior of the blends applied in the human body. Finally, it is also important to further test the mechanical strength of PLA/PPC blends during the degradation period to know the current strength of the implant in the healing process of the bone. Practical implications PLA fixation plate and screw can commercially be used in CMF surgery since they reduce cost because of the elimination of secondary surgery to remove the fixation plate and screw after the healing process. Social implications It is hoped that the advantages of this research will ensure the market of PLA product to continue expanding in medical application. Originality/value This study is one of the alternative ways for the biomedical researchers to improve the elongation break of PLA. Currently, many researchers focus on polymeric materials such as PLA, poly(glycolic) acid and polydioxanone blends, which were extensively being used in CMF surgery. However, the work on PLA/PPC blends to be used as one of the materials for the CMF fixation plate is very limited, if any. PPC, the proposed material for this research, will improve the mechanical performance of PLA fixation plate and screw to become more sustainable and flexible when applied on human mandible bone.


Paleobiology ◽  
2019 ◽  
Vol 45 (1) ◽  
pp. 182-200 ◽  
Author(s):  
François Clarac ◽  
Florent Goussard ◽  
Vivian de Buffrénil ◽  
Vittorio Sansalone

AbstractThis paper aims at assessing the influence of the bone ornamentation and, specifically, the associated loss of bone mass on the mechanical response of the crocodylomorph osteoderms. To this end, we have performed three-dimensional (3D) modeling and a finite element analysis on a sample that includes both extant dry bones and well-preserved fossils tracing back to the Late Triassic. We simulated an external attack under various angles on the apical surface of each osteoderm and further repeated the simulation on an equivalent set of smoothed 3D-modeled osteoderms. The comparative results indicated that the presence of an apical sculpture has no significant influence on the von Mises stress distribution in the osteoderm volume, although it produces a slight increase in its numerical score. Moreover, performing parametric analyses, we showed that the Young's modulus of the osteoderm, which may vary depending on the bone porosity, the collagen fiber orientation, or the calcification density, has no impact on the von Mises stress distribution inside the osteoderm volume. As the crocodylomorph bone ornamentation is continuously remodeled by pit resorption and secondary bone deposition, we assume that the apical sculpture may be the outcome of a trade-off between the bone mechanical resistance and the involvement in physiological functions. These physiological functions are indeed based on the setup of a bone superficial vessel network and/or the recurrent release of mineral elements into the plasma: heat transfers during basking and respiratory acidosis buffering during prolonged apnea in neosuchians and teleosaurids; compensatory homeostasis in response to general calcium deficiencies. On a general morphological basis, the osteoderm geometric variability within our sample leads us to assess that the global osteoderm geometry (whether square or rectangular) does not influence the von Mises stress, whereas the presence of a dorsal keel would somewhat reduce the stress along the vertical axis.


Sign in / Sign up

Export Citation Format

Share Document