scholarly journals Patients Undergoing Surgery for Hip Fractures Suffer from Severe Oxidative Stress as Compared to Patients with Hip Osteoarthritis Undergoing Total Hip Arthroplasty

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Theofilos Karachalios ◽  
Dionyssios Paridis ◽  
Fotios Tekos ◽  
Zoi Skaperda ◽  
Aristidis S. Veskoukis ◽  
...  

Hip fractures are associated with the highest degree of morbidity and mortality of all fractures in elderly patients and pose a major risk for subsequent fractures. Patients with hip fractures also present accelerated bone turnover despite early stable fracture fixation and early mobilization. We aimed to evaluate oxidative stress in two groups of patients (25 patients each, matched for age, side, and BMI) who underwent internal fixation of hip fractures and total hip arthroplasty for hip osteoarthritis. Blood samples were taken from all patients during admission, the day of surgery, the 4th postoperative day, and the 15th postoperative day. Reduced (GSH) and oxidized (GSSG) glutathione, GSH/GSSG, catalase (CAT), thiobarbituric acid reactive substances (TBARS), protein carbonyls (PC), and total antioxidant capacity (TAC) as a widely used battery of redox biomarkers were recorded from blood samples. Patients with hip fractures who undergo fixation surgery, compared to those with hip osteoarthritis, suffer significant oxidative stress with an active but insufficient first line of oxidative defense, an intensive first line reaction, a very active second line of oxidative defense, and a low plasma antioxidant capacity. Surgery worsened already present lipid- and protein-related tissue damage. The severe oxidative stress observed may explain high morbidity and mortality rates and high bone turnover status, as well as the high incidence of refractures. Furthermore, the question of whether antioxidant therapy measures should be introduced in the management of hip fracture patients is raised.

2017 ◽  
Vol 9 (2) ◽  
Author(s):  
Afshin Taheriazam ◽  
Amin Saeidinia

Total hip arthroplasty (THA) is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA) has a large number of advantages, although there are concerns about the higher complications in this procedure. Aim of our study was to evaluate the complications and outcomes of cementless one-stage BTHA in osteoarthritis patients. A total of 147 patients from 2009 till 2012, underwent one-stage BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with osteoarthritis was performed. We evaluated all patients clinically and radiologically with serial followups. A clinical hip score based upon the modified Harris Hip Score (MHHS) was performed preoperatively and again postoperatively. During the period of study 89 men (60.5%) and 58 women (39.4%) with a mean age of 54.67±7.08 years at the time of presentation were recruited. The mean surgical time was 2.8±0.25 hrs. The mean hospital stay was 3.83±0.65 days. Hemoglobin level decreased significantly after operation (P=0.038). There was two deep venous thromboses, one superficial infection and one temporal proneal palsy but no pulmonary embolism, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 41.64±5.42 in patients. MHHS score improved to 89.26±4.68 in the last followup (P=0.0001). Our results recommended the use of cementless one-stage BTHA through Hardinge approach in patients with bilateral hip osteoarthritis.


2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.


2016 ◽  
Vol 10 (1) ◽  
pp. 105-110 ◽  
Author(s):  
Motoki Sonohata ◽  
Masaru Kitajima ◽  
Shunsuke Kawano ◽  
Masaaki Mawatari

Background: Total hip arthroplasty (THA) for poliomyelitis is a problematic procedure due to difficulty in positioning the cup of the prosthesis in the true acetabulum and the risk of dislocation after THA due to the low muscle tone. Methods: We herein present a case of bilateral hip pain with a history of poliomyelitis. Radiograph showed bilateral hip osteoarthritis caused by hip dysplasia due to residual poliomyelitis in right hip joint or developing dysplasia of the hip joint in left hip joint. THA was performed to bilateral hip joints. Results: Six years after bilateral THA, bilateral hip pain significantly improved. Additionally, the muscle strength on the paralyzed right side partially improved. However, the muscle strength on the non-paralyzed left side did not significantly improve. No complications related to the surgery were observed. Conclusion: Promising early results were obtained for THA in our patient with residual poliomyelitis. However, surgeons should pay attention to the potential development of complications concerning THA that may arise due to the residual poliomyelitis.


2021 ◽  
Vol 99 (Supplement_3) ◽  
pp. 381-382
Author(s):  
Samantha N Barker ◽  
Treylr Jackson ◽  
John Richeson ◽  
Jeff A Carroll ◽  
Nicole C Burdick-Sanchez ◽  
...  

Abstract The objective of this study was to evaluate antioxidant capacity in plasma of beef calves challenged with LPS. Following an initial feeding period of 40 d, steers (n = 32; 379 kg ± 30.7) were transported to the Livestock Issues Research Unit’s Bovine Immunology Research and Development Complex and challenged intravenously with LPS (0.25 µg/kg BW) on d 41. Blood samples were collected via jugular catheter at -2, 0, 2, 4, 6, 8, 10, 12, 18, 24, 36 and 48 h relative to the LPS challenge at 0 h. Blood samples were processed to isolate plasma for indicators of oxidative stress with a colorimetric assay to determine ferric reducing antioxidant power (FRAP) values via concentration of ferrous iron (µM). Data were analyzed as repeated measures using the GLIMMIX procedure of SAS. Antioxidant values did vary with time (P &lt; 0.001) being greater (P &lt; 0.05) at -2, 0, 2, 36, and 48 h. Antioxidant capacity was reduced at 6 and 8 h (P &lt; 0.05), with the least FRAP value observed at 8 h post-challenge. Antioxidant capacity increased (P &lt; 0.05) again at 10 h, showing similar (P &gt; 0.05) concentrations to those observed at 4 h. By 24 h post-challenge, plasma FRAP values increased (P &lt; 0.05) similar to initial values at -2, 0, and 2 h. It can be inferred that oxidative stress contributes to reduced antioxidant capacity, ultimately interfering with animal growth and productivity. While these values reflect the oxidative stress response to an acute endotoxin challenge, and a subsequent recovery returning to homeostasis within 24 to 48 h, they may also correlate with other physiological and immunological indicators associated with an acute endotoxin challenge.


2020 ◽  
Vol 35 (9) ◽  
pp. 2480-2487
Author(s):  
Anne F. Mannion ◽  
Selina Nauer ◽  
Diren Arsoy ◽  
Franco M. Impellizzeri ◽  
Michael Leunig

Medicina ◽  
2019 ◽  
Vol 55 (3) ◽  
pp. 69 ◽  
Author(s):  
Kazunori Koseki ◽  
Hirotaka Mutsuzaki ◽  
Kenichi Yoshikawa ◽  
Yusuke Endo ◽  
Takayuki Maezawa ◽  
...  

Background and objectives: The Honda Walking Assistive device® (HWA) is a light and easywearable robot device for gait training, which assists patients’ hip flexion and extension movementsto guide hip joint movements during gait. However, the safety and feasibility of robot-assisted gaittraining after total hip arthroplasty (THA) remains unclear. Thus, we aimed to evaluate the safetyand feasibility of this gait training intervention using HWA in a patient who underwent THA.Materials and methods: The patient was a 76-year-old woman with right hip osteoarthritis. Gaittraining using HWA was implemented for 20 sessions in total, five times per week from 1 week to5 weeks after THA. Self-selected walking speed (SWS), step length (SL), cadence, timed up and go(TUG), range of motion (ROM) of hip extension, and hip abduction and extension torque weremeasured preoperatively, and at 1 (pre-HWA), 2, 3, 4, 5 (post-HWA), and 10 weeks (follow-up) afterTHA. The gait patterns at SWS without HWA were measured by using three-dimensional (3D) gaitanalysis and an integrated electromyogram (iEMG). Results: The patient completed 20 gait trainingsessions with no adverse event. Hip abduction torque at the operative side, hip extension torque,SWS, SL, and cadence were higher at post-HWA than at pre-HWA. In particular, SWS, TUG, andhip torque were remarkably increased 3 weeks after THA and improved to almost the same levelsat follow-up. Maximum hip extension angle and hip ROM during gait were higher at post-HWAthan at pre-HWA. Maximum and minimum anterior pelvic tilt angles were lower at post-HWA thanat pre-HWA. The iEMG of the gluteus maximus and gluteus medius in the stance phase were lowerat post-HWA than preoperatively and at pre-HWA. Conclusions: In this case, the gait training usingHWA was safe and feasible, and could be effective for the early improvement of gait ability, hipfunction, and gait pattern after THA.


Sign in / Sign up

Export Citation Format

Share Document