scholarly journals Biomechanical Properties in Different Types of Thin Corneas in Menoufia Population

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Adel Galal Zaky ◽  
Amin Faisal Ellakwa ◽  
Ahmed Ibrahim Basiony

Background. To evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in normal thin (NT) healthy corneas with central corneal thickness (CCT) of 470–500 μm with matched thickness in keratoconus suspect (KCS) and keratoconus (KC) eyes. Methods. A total of 103 eyes in three groups were included prospectively: NT, KCS, and KC groups based on clinical examination and Pentacam findings. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured using the ocular response analyzer (ORA). CCT, CH, and CRF were compared between the three groups and statistically analyzed by variance tests. Results. The three groups consisted of 44 NT, 26 KCS, and 33 KC. The mean CH measured was 8.689 ± 1.775, 9.051 ± 1.1190, and 8.129 ± 0.8539 mmHg in NT, KCS, and KC eyes, respectively. The mean CRF was 8.441 ± 1.663, 8.337 ± 1.114, and 7.2422 ± 1.3110 mmHg in NT, KCS, and KC eyes, respectively. Within the range of central corneal thickness (470–500 μm), only mean CRF was statistically significantly different between the NT and KC ( P < 0.05 ); there was no statistically significant difference between NT and KCS, nor was the mean CH between each group ( P > 0.05 ). Conclusions. CRF only can be helpful in differentiating KC from NT eyes; KCS could not be predicted with either corneal biomechanical metrics. There was no benefit from CH in differentiating between the three study groups.

2020 ◽  
Author(s):  
Adel Galal Zaky ◽  
Amin Faisal Ellakwa ◽  
Ahmed Ibrahim Basiony

Abstract Background:To evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in normal thin (NT) healthy corneas with central corneal thickness (CCT) 470-500 µm with matched thickness in keratoconus suspect (KCS) and keratoconus (KC) and eyes.Methods: A total of 103 eyes in three groups were included prospectively: NT, KCS and KC groups based on clinical examination and pentacam findings. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer (ORA). CCT ,CH and CRF were compared between the three groups and statistically analyzed by variance tests.Results:The three groups consisted of 44 NT, 26 KCS, and 33 KC. The mean CH measured was 8.689 ± 1.775, 9.051 ± 1.1190 and 8.129 ± 0.8539 mmHg in NT, KCS and KC eyes, respectively. The mean CRF was 8.441 ± 1.663, 8.337 ± 1.114 and 7.2422 ± 1.3110 mmHg in NT, KCS and KC eyes, respectively. Within range of central corneal thickness (470 – 500 µm), only mean CRF was statistically significantly different between the NT and KC (P < 0.05); there was no statistically significant difference between NT and KCS, nor the mean CH between each group (P > 0.05).Conclusions: CRF only can be helpful in differentiating KC from NT eyes; KCS could not be predicted with either corneal biomechanical metrics. No benefit from CH in differentiating between the three study groups.


2019 ◽  
Author(s):  
Adel Galal Zaky ◽  
Mohamed Samy Abd Elaziz ◽  
Hatem Mohamed Marey ◽  
Moatz Faiz Elsawy ◽  
Nermeen Mahmoud Badawi ◽  
...  

Abstract Background To assess and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in normal thin (NT) healthy corneas with central corneal thickness (CCT) 470-500 µm with matched thickness in keratoconus (KC) and keratoconus suspect (KCS) eyes. Methods A total of 66 eyes in three groups were included prospectively: NT, KCS and KC groups based on clinical examination and topography. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer. CH and CRF were compared between the three groups and statistically analyzed by variances test. Results The three groups consisted of 32 NT, 19 KCS, and 15 KC. The mean CH measured was 8.55± 1.77, 9.03± 1.119 and 8.06 ± 0.85 mm Hg in NT, KCS and KC eyes, respectively. The mean CRF was 8.39 ± 1.47, 8.27 ± 1.09 and 7.24 ± 1.27 mm Hg in NT, KCS and KC eyes, respectively. Within range of central corneal thickness (470 – 500 µm), only mean CRF was statistically significantly different between the NT and KC (P < 0.05); there was no statistically significant difference between NT and KCS, nor the mean CH between each groups (P > 0.05). Conclusions CRF only can be helpful in differentiating KC from NT eyes; however, it’s not valuable for detecting KCS which is the main concern for refractive surgery. No benefit from CH in differentiating between the study groups. Further investigations & work focusing on more accurate tests for identifying KCS are still needed.


2019 ◽  
Vol 104 (4) ◽  
pp. 563-568 ◽  
Author(s):  
Masato Matsuura ◽  
Hiroshi Murata ◽  
Yuri Fujino ◽  
Mieko Yanagisawa ◽  
Yoshitaka Nakao ◽  
...  

AimsCorvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA).MethodsA total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis.ResultsIOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001).ConclusionThe bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.


2020 ◽  
pp. 112067212090203
Author(s):  
Yaping Yang ◽  
Jun Ye ◽  
Tsz Kin Ng ◽  
Na Wu ◽  
Xinghuai Sun ◽  
...  

Purpose: To evaluate the changes of corneal biomechanics and the intraocular pressure during pregnancy in a Chinese healthy female population. Methods: A total of 222 unrelated Chinese females were recruited: 52 non-pregnant, 15 pregnant in the first trimester, 68 pregnant in the second trimester, and 87 pregnant in the third trimester. The intraocular pressure and corneal biomechanical parameters, including corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, corneal hysteresis, and corneal resistance factor, were measured by an Ocular Response Analyzer G3. Central corneal thickness was measured by Lenstar (LS900). Results: Corneal hysteresis and corneal resistance factor were significantly higher in pregnant women at the second and third trimesters. Corneal-compensated intraocular pressure was lower in women at the third trimester of pregnancy ( p = 0.023), but the difference became insignificant after adjustment for corneal hysteresis. Central corneal thickness was marginally higher in pregnant women than non-pregnant women ( p = 0.032). There was a negative correlation between corneal-compensated intraocular pressure and corneal hysteresis ( r = −0.337, p < 0.001) and a positive correlation between central corneal thickness and corneal hysteresis ( r = 0.711, p < 0.0001). After adjustment for corneal-compensated intraocular pressure, corneal hysteresis remained significantly higher in the second and third trimesters of pregnant women than non-pregnant women ( p = 0.031, p = 0.005). Conclusion: This study revealed a significant increase in corneal hysteresis and corneal resistance factor in the second and third trimesters. The increase of corneal hysteresis was independent of corneal-compensated intraocular pressure, indicating pregnant females have unique characteristics in corneal-compensated intraocular pressure and corneal biomechanical properties that may be related to glaucoma and corneal ectatic diseases in pregnancy.


The Eye ◽  
2019 ◽  
Vol 21 (128) ◽  
pp. 15-19
Author(s):  
Irina Bubnova ◽  
Veronica Averich ◽  
Elena Belousova

Purpose: Evaluation of corneal biomechanical prop¬erties and their influence on IOP indices in patients with keratoconus. Material and methods. The study included 194 eyes with keratoconus (113 patients aged from 23 to 36 years old). Corneal refraction in central zone varied from 48.25 to 56.75 D, values of corneal thickness ranged from 279 to 558 μm. Patients were divided into 4 groups according to Amsler classification: I stage – 40 eyes; II stage – 78 eyes; III stage – 54 eyes and IV stage – 22 eyes. Standard ophthal¬mological examination was carried out including pneumo¬tonometry. IOP indices and values of biomechanical prop¬erties were evaluated by dynamic bidirectional pneumatic applanation and pneumatic impression. Results. Study of corneal biomechanical properties in patients with keratoconus showed a decrease of such biomechanical indices as corneal hysteresis (CH) on aver¬age to 8.42±1.12 mm Hg, corneal resistance factor (CRF) – to 7.45±0.96 mm Hg, coefficient of elasticity (CE) – 5.35± 0.87 mm Hg. Values of these indices strongly depended on the stage of keratoconus. In the whole sample, the aver¬age corneal compensated IOP (IOPcc) amounted to 15.08± 2.43 mm Hg, Goldman IOP (IOPg) was 11.61±2.37 mm Hg and pneumatic tonometry IOP (IOPp) was 10.13±2.94 mm Hg. IOPcc indices didn’t have any statistically significant differ¬ence in dependence on the stage of keratoconus (р>0.473), while in process of disease progression IOPg and IOPp indi¬ces showed statistically significant decrease of mean values. Conclusion. Progression of keratoconus led to a de¬crease in corneal biomechanical properties which deter¬mine reduction of such indices as IOPg and IOPp in contrast to IOPcc.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.


2016 ◽  
Vol 15 (2) ◽  
Author(s):  
Satheesh Solomon T Selvin ◽  
Chris Elsa Samson Jacob ◽  
Thomas Kuriakose

Purpose: Goldmann applanation tonometry (GAT) is considered the gold standard for Intraocular Pressure (IOP) measurement. It has the disadvantages of being a contact device, need for a slit-lamp, non-portability and need of a skilled examiner. Many hospitals are using a Non Contact Tonometry (NCT) as a screening device to save clinician time, however the usefulness is not proved in terms of reliability. This study was aimed to determine the usefulness of the Air-puff tonometer (TONOREF NIDEK II, NIDEK CO., LTD., JAPAN) over a GAT in a tertiary care center. Design: Cross-sectional Study Methods: This was a cross-sectional, non interventional observational study conducted on 224 eyes (right eye) from 224 patients. All patients underwent the IOP measurement with both methods and a central corneal thickness (CCT) measured. The data was analyzed using SPSS 20.0 software. Results: The mean age of the patients was 40.3±11.29 years. There was a statistically significant difference (p<0.001) between the mean NCT and GAT readings which persisted even after correction for central corneal thickness. The correlation between NCT and GAT using Pearson’s correlation coefficient was strong irrespective of the corrections for their corneal thickness (r = 0.751 and 0.718 for uncorrected and corrected values respectively). The correlation of the individual clinicians for the readings varied from moderate to strong. The ROC curve showed the best sensitivity and specificity to occur at around 13 to 14 mmHg. Conclusion: NCT seems to overestimate the IOP at low ranges as compared to the GAT and underestimate at higher ranges. The crossover of the values is seen between 12 to 13 mmHg.  The clinician should do an individualized analysis of his/her GAT measurements to the readings of the NCT machine at the clinic to obtain clinician specific nomogram. 


2021 ◽  
Vol 9 (2) ◽  
pp. 127-133
Author(s):  
Annamary Stanislaus ◽  
Ntsilane Susan Mosenene ◽  
Celina Mhina ◽  
John Stanslaus Kisimbi ◽  
Frederick Robert Burgess ◽  
...  

Background: Central Corneal Thickness (CCT) is an indicator of corneal health status as well as being an essential tool in assessment and management of corneal diseases. It is an important factor in the diagnosis and management of glaucoma as it affects the measurement of intraocular pressure. However, the pattern of central corneal thickness in our population is not known. Our study aimed to describe the CCT measurements and their variation with age and sex among patients attending the eye clinic at Muhimbili National Hospital (MNH), in Dar es Salaam, Tanzania. Methodology: A hospital-based descriptive, cross-sectional study used convenient sampling to recruit adult patients aged 18 years and above, presenting to the MNH between August 2016 and January 2017.Visual acuity assessment, Goldman applanation tonometry and CCT assessment using an ultrasound pachymeter were performed. Patients with previous intraocular surgery were excluded. Results: A total of 398 patients (208 males and 190 females) were recruited. The mean CCT was 526.64±38.30 µm; being 523.99±38.20 µm for males and 529.7±38.3 µm for females. 226 (56.85%) had CCT of less than 520 µm.There was no statistically significant difference in CCT between gender. The proportion of patients with thinner CCT increased with increasing age from 25.8% in those < 30 years to 75% in those aged 71years and above. The mean CCT decreased with increasing age with P-value<0.001. Conclusion: The average CCT in patients attending Muhimbili National Hospital is 526.64 µm (SD 38.30) which is generally thin, inversely proportion to age and similar that of other Africans and African-Americans. This finding has implications for the management of glaucoma in this population.


2017 ◽  
Vol 27 (5) ◽  
pp. 535-541 ◽  
Author(s):  
Laura Díez-Álvarez ◽  
Francisco J. Muñoz-Negrete ◽  
Pilar Casas-Llera ◽  
Noelia Oblanca ◽  
Victoria de Juan ◽  
...  

Purpose To evaluate corneal biomechanical properties and optic nerve head (ONH) changes following deep sclerectomy (DS) and the relation to each other. Methods Forty-nine eyes with primary open-angle glaucoma that underwent DS were studied. Corneal biomechanical properties were assessed using the Ocular Response Analyzer and the ONH was evaluated by Spectralis optical coherence tomography with enhanced depth imaging technology before surgery and 3 months postoperatively. Changes in corneal hysteresis (CH), corneal resistance factor (CRF), optic nerve cupping, prelaminar tissue thickness, and lamina cribrosa depth and thickness were registered. A correlation matrix and multiple linear regression models were used to determine predictors of ONH changes. Results At 3 months after surgery, mean corneal compensated intraocular pressure (IOPcc) significantly decreased by 27.9% (p<00.001) and mean Goldmann-correlated IOP (IOPg) decreased by 30.52% (p<00.001). Mean CH increased and CRF decreased by 18.4% and 10.1%, respectively (p<00.001). There was a significant reversal of ONH cupping mainly due to a prelaminar tissue thickening (p<00.001). Significant associations were found between ONH cupping reversal and prelaminar tissue thickening with preoperative IOPcc (p = 0.046), IOPg (p = 0.02), and CRF (p = 0.002) and with changes in IOP, CH, and CRF (p<00.001, p = 0.004, p = 0.018, respectively) after surgery. Conclusions Corneal hysteresis increased and CRF decreased significantly 3 months after DS. Corneal resistance factor was the single largest preoperative factor influencing cupping reversal changes. Despite the influence of preoperative variables, postoperative IOP reduction was the only independent factor influencing changes observed in the ONH after surgery.


2020 ◽  
pp. 112067212091453
Author(s):  
Ali Keleş ◽  
Emine Şen ◽  
Ufuk Elgin

Purpose: The aims of this study were to compare the biometric parameters and axial lengths of eyes with phacomorphic glaucoma and mature cataract and to identify differences that might predispose to development of phacomorphic glaucoma. Methods: Three hundred forty-two patients were enrolled in this retrospective study. The eyes were divided into four groups—Group (G)1: phacomorphic glaucoma ( n = 29), G2: mature cataract ( n = 313), G3: contralateral phacomorphic glaucoma ( n = 29), and G4: contralateral mature cataract ( n = 313). Central corneal thickness and anterior chamber depth were assessed by optical low-coherence reflectometry (Lenstar LS 900®; Haag-Streit AG, Switzerland), while axial length was determined by A-scan ultrasound biometry. Results: The mean central corneal thickness of G1 was significantly higher than in other groups ( p < 0.001) and the mean anterior chamber depth of G1 was the lowest among the groups ( p < 0.001). Also, G2 had lower mean anterior chamber depth than G4 ( p < 0.001) and G3 had lower mean anterior chamber depth than G4 ( p = 0.007). Anterior chamber depth less than 3.27 mm had the higher odds ratio for distinguishing G3 versus G4 (odds ratio = 10.79, p < 0.001). Furthermore, patients aged ⩾68.9 years had the higher odds ratio for distinguishing G1 versus G2 (odds ratio = 2.82, p = 0.019). There was no significant difference in the presence of pseudoexfoliation material between G1 and G2 ( p = 0.057). There were no significant differences in axial length values among the four groups ( p = 0.097). Conclusion: Advanced age and shallow anterior chamber depth were found to be risk factors for developing phacomorphic glaucoma, but the presence of pseudoexfoliation material was not found to play a role as a risk factor in phacomorphic glaucoma development.